主动脉球囊阻断联合经皮左心室辅助装置在猪心脏骤停心肺复苏中的血流动力学影响
该研究在24头猪中诱导心室颤动8分钟不予处理,随后进行16分钟机械心肺复苏,随机分为经皮左心室辅助装置(pL-VAD)组、pL-VAD+主动脉球囊阻断(AO)组和AO组,每组8头。结果显示,pL-VAD+AO组冠脉灌注压平均升高29.2 mmHg,显著高于pL-VAD组的7.1 mmHg和AO组的7.1 mmHg(p=0.02);脑灌注压平均升高23.6 mmHg,显著高于另两组的0.97 mmHg和6.9 mmHg(p<0.001)。自主循环恢复率在pL-VAD+AO组为87.5%,pL-VAD组为75%,AO组为100%。结论认为,在猪长时间心脏骤停模型中,联合应用AO和pL-VAD较单用任一干预改善了心肺复苏血流动力学。
要点
- 在猪长时间心脏骤停模型中,pL-VAD+AO组冠脉灌注压平均升高29.2 mmHg,高于pL-VAD组的7.1 mmHg和AO组的7.1 mmHg(p=0.02)。
- pL-VAD+AO组脑灌注压平均升高23.6 mmHg,高于pL-VAD组的0.97 mmHg和AO组的6.9 mmHg(p<0.001)。
- 自主循环恢复率:pL-VAD+AO组87.5%,pL-VAD组75%,AO组100%。
- 该研究为猪模型,样本量24头,每组8头,结果需在临床环境中进一步验证。
适用人群与场景
- 猪长时间心脏骤停模型:心室颤动诱导后8分钟不予处理,随后进行16分钟机械心肺复苏。
处置流程与药物剂量
- 经股动脉插入Impella CP®和主动脉球囊导管;治疗期间持续机械心肺复苏。
- 从第28分钟开始尝试除颤3次,之后每4分钟除颤一次。
研究设计与关键结果
- 研究类型:随机对照动物实验;样本量24头猪,随机分为3组(每组8头):pL-VAD组(Impella CP®)、pL-VAD+AO组、AO组。
- 冠脉灌注压变化:pL-VAD+AO组平均(标准差)升高29.2(13.94)mmHg,pL-VAD组升高7.1(12.08)mmHg,AO组升高7.1(5.95)mmHg(p=0.02)。
- 脑灌注压变化:pL-VAD+AO组平均(标准差)升高23.6(6.11)mmHg,pL-VAD组升高0.97(9.07)mmHg,AO组升高6.9(7.98)mmHg(p<0.001)。
- 自主循环恢复率:pL-VAD+AO组87.5%,pL-VAD组75%,AO组100%。
证据类型、等级与局限
- 证据类型:随机对照动物实验(猪模型)。
- 局限:原文未报告局限性。
对床旁实践的改变
- 在猪长时间心脏骤停模型中,联合应用AO和pL-VAD较单用任一干预改善了心肺复苏血流动力学(冠脉灌注压和脑灌注压升高)。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
AIM: To investigate the effect of tandem use of transient balloon occlusion of the descending aorta (AO) and percutaneous left ventricular assist device (pl-VAD) during cardiopulmonary resuscitation in a large animal model of prolonged cardiac arrest.
METHODS: Ventricular fibrillation was induced and left untreated for 8 minutes followed by 16 minutes of mechanical CPR (mCPR) in 24 swine, under general anesthesia. Animals were randomized to 3 treatment groups (n = 8 per group): A) pL-VAD (Impella CP®) B) pL-VAD+AO, and C) AO. Impella CP® and the aortic balloon catheter were inserted via the femoral arteries. mCPR was continued during treatment. Defibrillation was attempted 3 times starting at minute 28 and then every 4 minutes. Haemodynamic, cardiac function and blood gas measurements were recorded for up to 4 hours.
RESULTS: Coronary perfusion pressure (CoPP) in the pL-VAD+AO Group increased by a mean (SD) of 29.2(13.94) mmHg compared to an increase of 7.1(12.08) and 7.1(5.95) mmHg for groups pL-VAD and AO respectively (p = 0.02). Similarly, cerebral perfusion pressure (CePP) in pL-VAD+AO increased by a mean (SD) of 23.6 (6.11), mmHg compared with 0.97 (9.07) and 6.9 (7.98) mmHg for the other two groups (p < 0.001). The rate of return of spontaneous heartbeat (ROSHB) was 87.5%, 75%, and 100% for pL-VAD+AO, pL-VAD, and AO.
CONCLUSION: Combined AO and pL-VAD improved CPR hemodynamics compared to either intervention alone in this swine model of prolonged cardiac arrest.
参考来源
- Tiba MH, Nakashima T, McCracken BM, et al. Haemodynamic impact of aortic balloon occlusion combined with percutaneous left ventricular assist device during cardiopulmonary resuscitation in a swine model of cardiac arrest. Resuscitation. 2023. PMID: 37385400. doi:10.1016/j.resuscitation.2023.109885
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。