文献速递中毒与环境急症

脉搏碳氧血氧仪评估血中碳氧血红蛋白水平的准确性:诊断准确性研究的系统评价与Meta分析

Accuracy of pulse CO-oximetry to evaluate blood carboxyhemoglobin level: a systematic review and meta-analysis of diagnostic test accuracy studies.
PubMed 文献 · Eur J Emerg Med · 2023-05-31
一句话结论脉搏碳氧血氧仪测SpCO的汇总敏感度0.77、特异度0.83、一致性界限宽(-7.08%至8.57%),似乎不能确切确认或排除一氧化碳中毒。

该研究为诊断准确性研究的系统评价与Meta分析,检索Medline、Embase、Cochrane CENTRAL和OpenGrey(2022年8月2日),纳入2000年以来比较SpCO与血COHb水平的人体研究。21项研究符合纳入标准,11项进入主要指标定量分析,18项进入次要指标分析;汇总ROC曲线下面积86%,平均敏感度0.77(95%CI 0.66-0.85)、特异度0.83(95%CI 0.74-0.89)(2089名受试者、3381次观测)。平均偏倚0.75%,一致性界限-7.08%至8.57%(95%CI -8.89至10.38)(2794名受试者、4646次观测)。作者认为现有脉搏碳氧血氧仪测SpCO似乎不够准确,可能不应被用于确切确认(rule-in)或排除(rule-out)一氧化碳中毒。

要点

  • 汇总敏感度0.77(95%CI 0.66-0.85)、特异度0.83(95%CI 0.74-0.89),诊断准确性仅为中等。
  • 平均偏倚0.75%,一致性界限-7.08%至8.57%(95%CI -8.89至10.38),个体测量误差范围大。
  • 汇总ROC曲线下面积86%(11项研究、2089名受试者、3381次观测)。
  • 作者认为SpCO似乎不能确切确认(rule-in)或排除(rule-out)一氧化碳中毒。
  • 未发现发表偏倚;采用QUADAS-2工具评价偏倚风险。

适用人群与场景

  • 2000年以来发表的所有设计的研究,对象为人类志愿者或患者,包括儿童,比较SpCO测量与血COHb水平的准确性和可靠性。

研究设计与关键结果

  • 系统评价与Meta分析(诊断准确性研究),检索Medline、Embase、Cochrane CENTRAL和OpenGrey(2022年8月2日),21项研究符合纳入标准,11项进入主要指标定量分析,18项进入次要指标分析。
  • 主要指标:汇总ROC曲线下面积86%;平均敏感度0.77(95%CI 0.66-0.85)、特异度0.83(95%CI 0.74-0.89)(2089名受试者、3381次观测)。
  • 次要指标:平均偏倚0.75%,一致性界限-7.08%至8.57%(95%CI -8.89至10.38)(2794名受试者、4646次观测)。
  • 未发现发表偏倚。

证据类型、等级与局限

  • 证据类型:诊断准确性研究的系统评价与Meta分析,按PRISMA-DTA 2018指南进行,注册于PROSPERO(CRD42020177940),偏倚风险用QUADAS-2工具评价。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,现有脉搏碳氧血氧仪测SpCO似乎不够准确(敏感度和特异度中等、一致性界限大),可能不应被用于确切确认(rule-in)或排除(rule-out)一氧化碳中毒。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

Carbon monoxide (CO) poisoning is one of the most common causes of poisoning death and its diagnosis requires an elevated carboxyhemoglobin (COHb) level. Noninvasive CO saturation by pulse oximetry (SpCO) has been available since 2005 and has the advantage of being portable and easy to use, but its accuracy in determining blood COHb level is controversial. To evaluate the accuracy of SpCO (index test) to estimate COHb (reference test). Systematic review and meta-analysis of diagnostic test accuracy (DTA) studies. Four electronic databases were searched (Medline, Embase, Cochrane Central Register of Controlled Trials, and OpenGrey) on 2 August 2022. All studies of all designs published since the 2000s evaluating the accuracy and reliability of SpCO measurement compared to blood COHb levels in human volunteers or ill patients, including children, were included. The primary outcome was to assess the diagnostic accuracy of SpCO for estimating COHb by blood sampling by modeling receiver operating characteristic (ROC) curves and calculating sensitivity and specificity (primary measures). The secondary measures were to calculate the limits of agreement (LOA) and the mean bias. This systematic review was conducted according to the Preferred Reporting Items for a Systematic Review and Meta-analysis-DTA 2018 guidelines and has been registered on International Prospective Register of Systematic Reviews (PROSPERO, CRD42020177940). The risk of bias was evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Twenty-one studies were eligible for the systematic review; 11 could be included for the quantitative analysis of the primary measures and 18 for the secondary measures. No publication bias was found. The area under the summary ROC curve was equal to 86%. The mean sensitivity and specificity were 0.77, 95% confidence interval (CI, 0.66-0.85) and 0.83, 95% CI (0.74-0.89), respectively (2089 subjects and 3381 observations). The mean bias was 0.75% and the LOA was -7.08% to 8.57%, 95% CI (-8.89 to 10.38) (2794 subjects and 4646 observations). Noninvasive measurement of COHb (SpCO) using current pulse CO oximeters do not seem to be highly accurate to estimate blood COHb (moderate sensitivity and specificity, large LOA). They should probably not be used to confirm (rule-in) or exclude (rule-out) CO poisoning with certainty.

来源:Eur J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Papin M, Latour C, Leclère B, et al. Accuracy of pulse CO-oximetry to evaluate blood carboxyhemoglobin level: a systematic review and meta-analysis of diagnostic test accuracy studies. Eur J Emerg Med. 2023. PMID: 37171830. doi:10.1097/MEJ.0000000000001043

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。