气道压力释放通气对早期中重度ARDS患者肺生理的影响:基于电阻抗断层成像的研究
本研究为单中心前瞻性生理研究,纳入12例接受APRV机械通气的早期中重度ARDS成人患者,在APRV启用后即刻(T0)及6小时(T1)、12小时(T2)、24小时(T3)用电阻抗断层成像(EIT)评估区域通气与灌注分布、死腔(%)、分流(%)及通气/灌注匹配(%)。结果显示APRV后肺通气与灌注显著向背侧区域重新分布,整体不均一性指数由0.61(0.55-0.62)降至0.50(0.42-0.53)(p<0.001),通气中心由43.31±5.07%逐渐向背侧移至46.84±4.96%(p=0.048),背侧通气/灌注匹配由T0的25.72±9.01%升至T3的29.80±7.19%(p=0.007)。背侧通气(%)越好与PaO2/FiO2越高(r=0.624,p=0.001)及PaCO2越低(r=-0.408,p=0.048)显著相关。作者认为APRV优化通气与灌注分布、降低肺不均一性,可能降低呼吸机相关肺损伤风险。
要点
- 12例早期中重度ARDS成人患者启用APRV后,EIT示肺通气与灌注显著向背侧区域重新分布。
- 整体不均一性指数由0.61(0.55-0.62)降至0.50(0.42-0.53)(p<0.001),通气中心由43.31±5.07%移至46.84±4.96%(p=0.048)。
- 背侧通气/灌注匹配由T0的25.72±9.01%升至T3的29.80±7.19%(p=0.007)。
- 背侧通气(%)越高与PaO2/FiO2越高(r=0.624,p=0.001)、PaCO2越低(r=-0.408,p=0.048)显著相关。
- 作者认为APRV优化通气与灌注分布、降低肺不均一性,可能降低呼吸机相关肺损伤风险。
适用人群与场景
- 早期中重度ARDS成人患者,接受APRV机械通气。
研究设计与关键结果
- 单中心前瞻性生理研究,纳入12例早期中重度ARDS成人患者,在APRV启用后即刻(T0)及6小时(T1)、12小时(T2)、24小时(T3)行EIT评估。
- APRV后肺通气与灌注显著向背侧区域重新分布;整体不均一性指数由0.61(0.55-0.62)降至0.50(0.42-0.53)(p<0.001),通气中心由43.31±5.07%移至46.84±4.96%(p=0.048)。
- 背侧通气/灌注匹配由T0的25.72±9.01%升至T3的29.80±7.19%(p=0.007)。
- 背侧通气(%)越高与PaO2/FiO2越高(r=0.624,p=0.001)及PaCO2越低(r=-0.408,p=0.048)显著相关。
证据类型、等级与局限
- 证据类型:单中心前瞻性生理研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为APRV优化通气与灌注分布、降低肺不均一性,可能降低呼吸机相关肺损伤风险。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVE: The aim of this study was to investigate the physiological impact of airway pressure release ventilation (APRV) on patients with early moderate-to-severe acute respiratory distress syndrome (ARDS) by electrical impedance tomography (EIT).
METHODS: In this single-center prospective physiological study, adult patients with early moderate-to-severe ARDS mechanically ventilated with APRV were assessed by EIT shortly after APRV (T0), and 6 h (T1), 12 h (T2), and 24 h (T3) after APRV initiation. Regional ventilation and perfusion distribution, dead space (%), shunt (%), and ventilation/perfusion matching (%) based on EIT measurement at different time points were compared. Additionally, clinical variables related to respiratory and hemodynamic condition were analyzed.
RESULTS: Twelve patients were included in the study. After APRV, lung ventilation and perfusion were significantly redistributed to dorsal region. One indicator of ventilation distribution heterogeneity is the global inhomogeneity index, which decreased gradually [0.61 (0.55-0.62) to 0.50 (0.42-0.53), p < 0.001]. The other is the center of ventilation, which gradually shifted towards the dorsal region (43.31 ± 5.07 to 46.84 ± 4.96%, p = 0.048). The dorsal ventilation/perfusion matching increased significantly from T0 to T3 (25.72 ± 9.01 to 29.80 ± 7.19%, p = 0.007). Better dorsal ventilation (%) was significantly correlated with higher PaO2/FiO2 (r = 0.624, p = 0.001) and lower PaCO2 (r = -0.408, p = 0.048).
CONCLUSIONS: APRV optimizes the distribution of ventilation and perfusion, reducing lung heterogeneity, which potentially reduces the risk of ventilator-induced lung injury.
参考来源
- Li R, Wu Y, Zhang H, et al. Effects of airway pressure release ventilation on lung physiology assessed by electrical impedance tomography in patients with early moderate-to-severe ARDS. Crit Care. 2023. PMID: 37158961. doi:10.1186/s13054-023-04469-8
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。