膈肌超声预测机械通气脱机成功的有效性:系统评价与Meta分析
该研究纳入26项研究(其中19项进入Meta分析,共1204例患者),评估膈肌超声预测机械通气脱机成功的诊断准确性。膈肌移动度的敏感性为0.80(95%CI 0.77-0.83)、特异性为0.80(95%CI 0.75-0.84),诊断比值比(DOR)为17.1(95%CI 10.2-28.6);膈肌增厚分数的敏感性为0.85(95%CI 0.82-0.87)、特异性为0.75(95%CI 0.69-0.80),DOR为17.2(95%CI 9.16-32.3)。两者汇总受试者工作特征曲线下面积均为0.87。研究间存在异质性,患者测试时的体位是异质性来源之一。结论认为,两者预测脱机成功具有满意的诊断准确性,但仍需在ICU特定亚组患者中开展高质量研究。
要点
- 膈肌增厚分数预测脱机成功:敏感性0.85(95%CI 0.82-0.87),特异性0.75(95%CI 0.69-0.80),DOR 17.2(95%CI 9.16-32.3)。
- 膈肌移动度预测脱机成功:敏感性0.80(95%CI 0.77-0.83),特异性0.80(95%CI 0.75-0.84),DOR 17.1(95%CI 10.2-28.6)。
- 两项指标的汇总受试者工作特征曲线下面积均为0.87,诊断准确性满意。
- 研究间存在显著异质性;双变量Meta回归显示,测试时患者体位是异质性来源之一。
- 采用压力支持(PS)通气与T管试验的研究相比,敏感性和特异性无显著差异。
适用人群与场景
- 接受机械通气、拟评估脱机的成人患者(纳入研究的人群)。
研究设计与关键结果
- 系统评价与Meta分析,共纳入26项研究,其中19项进入Meta分析(1204例患者),评估膈肌超声预测机械通气脱机成功的诊断准确性。
- 膈肌移动度:敏感性0.80(95%CI 0.77-0.83),特异性0.80(95%CI 0.75-0.84),汇总受试者工作特征曲线下面积0.87,诊断比值比(DOR)17.1(95%CI 10.2-28.6)。
- 膈肌增厚分数:敏感性0.85(95%CI 0.82-0.87),特异性0.75(95%CI 0.69-0.80),汇总受试者工作特征曲线下面积0.87,DOR 17.2(95%CI 9.16-32.3)。
- 研究间存在异质性;排除采用非典型截断值的研究后,膈肌增厚分数的敏感性和特异性均升高,膈肌移动度的敏感性升高、特异性降低。
- 比较采用压力支持(PS)通气与T管试验的研究,敏感性和特异性无显著差异。
- 双变量Meta回归分析显示,测试时患者体位是纳入研究的异质性来源之一。
证据类型、等级与局限
- 证据类型:系统评价与Meta分析;采用QUADAS-2工具评估方法学质量,采用GRADE方法评估证据确定性。
- 局限:纳入研究间存在显著异质性;作者指出需要在ICU特定亚组患者中开展高质量研究,以评估膈肌超声作为脱机预测指标的作用。
对床旁实践的改变
- 作者认为,测量膈肌移动度和膈肌增厚分数可预测机械通气脱机成功的概率,具有满意的诊断准确性。
- 作者指出,纳入研究间存在显著异质性,需要在ICU特定亚组患者中开展高质量研究,以评估膈肌超声作为脱机预测指标的作用。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Several measurements have been used to predict the success of weaning from mechanical ventilation; however, their efficacy varies in different studies. In recent years, diaphragmatic ultrasound has been used for this purpose. We conducted a systematic review and meta-analysis to evaluate the effectiveness of diaphragmatic ultrasound in predicting the success of weaning from mechanical ventilation.
METHODS: Two investigators independently searched PUBMED, TRIP, EMBASE, COCHRANE, SCIENCE DIRECT, and LILACS for articles published between January 2016 and July 2022. The methodological quality of the studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool; additionally, the certainty of the evidence is evaluated using the GRADE (Grading of Recommendations Assessment, Development, and Evaluation) methodology. Sensitivity and specificity analysis was performed for diaphragmatic excursion and diaphragmatic thickening fraction; positive and negative likelihood ratios and diagnostic odds ratios (DOR) with their confidence intervals (95% CI) were calculated by random effects analysis, summary receiver operating characteristic curve was estimated. Sources of heterogeneity were explored by subgroup analysis and bivariate meta-regression.
RESULTS: Twenty-six studies were included, of which 19 were included in the meta-analysis (1204 patients). For diaphragmatic excursion, sensitivity was 0.80 (95% CI 0.77-0.83), specificity 0.80 (95% CI 0.75-0.84), area under the summary receiver operating characteristic curve 0.87 and DOR 17.1 (95% CI 10.2-28.6). For the thickening fraction, sensitivity was 0.85 (95% CI 0.82-0.87), specificity 0.75 (95% CI 0.69-0.80), area under the summary receiver operating characteristic curve 0.87 and DOR 17.2 (95% CI 9.16-32.3). There was heterogeneity among the included studies. When performing a subgroup analysis and excluding studies with atypical cutoff values, sensitivity and specificity increased for diaphragmatic thickening fraction; sensitivity increased and specificity decreased for diaphragmatic excursion; when comparing studies using pressure support (PS) versus T-tube, there was no significant difference in sensitivity and specificity; bivariate meta-regression analysis shows that patient position at the time of testing was a factor of heterogeneity in the included studies.
CONCLUSIONS: Measurement of diaphragmatic excursion and diaphragmatic thickening fraction predict the probability of successful weaning from mechanical ventilation with satisfactory diagnostic accuracy; however, significant heterogeneity was evident in the different included studies. Studies of high methodological quality in specific subgroups of patients in intensive care units are needed to evaluate the role of diaphragmatic ultrasound as a predictor of weaning from mechanical ventilation.
参考来源
- Parada-Gereda HM, Tibaduiza AL, Rico-Mendoza A, et al. Effectiveness of diaphragmatic ultrasound as a predictor of successful weaning from mechanical ventilation: a systematic review and meta-analysis. Crit Care. 2023. PMID: 37147688. doi:10.1186/s13054-023-04430-9
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。