瓣环收缩期峰值流速的呼吸变异率作为脓毒性休克患者容量反应性新指标
本研究纳入33例脓毒性休克患者,用经胸超声心动图测量主动脉速度时间积分呼吸变异率(∆VTI)、三尖瓣环收缩期峰值流速呼吸变异率(∆RVS)、二尖瓣环收缩期峰值流速呼吸变异率(∆LVS)及三尖瓣环收缩期位移(TAPSE),以扩容后心输出量增加10%定义容量反应性。容量反应阳性组17例、阴性组16例,两组人群特征无显著差异(P>0.05)。∆RVS、∆LVS、TAPSE与扩容后心输出量相对增加量相关(R=0.55,P=0.001;R=0.40,P=0.02;R=0.36,P=0.041),多因素logistic回归显示三者与容量反应性显著相关。ROC曲线分析显示∆VTI、∆LVS、∆RVS、TAPSE的AUC分别为0.952、0.802、0.822、0.713,最佳阈值分别为0.128、0.129、0.130、13.9 mm。作者认为组织多普勒评估二尖瓣和三尖瓣环收缩期峰值流速呼吸变异率是简单评估脓毒性休克患者容量反应性的可行、可靠方法。
要点
- 脓毒性休克患者扩容后心输出量增加10%定义为容量反应性,33例中阳性17例、阴性16例。
- ∆RVS与扩容后心输出量相对增加量相关(R=0.55,P=0.001),∆LVS相关(R=0.40,P=0.02),TAPSE相关(R=0.36,P=0.041)。
- 预测容量反应性:∆VTI的AUC 0.952(敏感度1.00、特异度0.84、阈值0.128),∆RVS的AUC 0.822(敏感度0.81、特异度0.76、阈值0.130)。
- ∆LVS的AUC 0.802(敏感度0.73、特异度0.91、阈值0.129),TAPSE的AUC 0.713(敏感度0.83、特异度0.67、阈值13.9 mm)。
- 多因素logistic回归显示∆RVS、∆LVS、TAPSE与脓毒性休克患者容量反应性显著相关。
适用人群与场景
- 脓毒性休克患者,共33例,容量反应阳性组17例、阴性组16例。
诊断标准与关键阈值
- 容量反应性定义:扩容后心输出量增加10%,用经胸超声心动图评估。
- 预测容量反应性的最佳阈值:∆VTI 0.128,∆LVS 0.129,∆RVS 0.130,TAPSE 13.9 mm。
研究设计与关键结果
- 研究类型为超声指标评估研究,纳入33例脓毒性休克患者,比较容量反应阳性组(n=17)与阴性组(n=16),两组人群特征无显著差异(P>0.05)。
- Pearson相关分析:∆RVS与扩容后心输出量相对增加量相关(R=0.55,P=0.001),∆LVS相关(R=0.40,P=0.02),TAPSE相关(R=0.36,P=0.041)。
- 多因素logistic回归分析显示∆RVS、∆LVS、TAPSE与脓毒性休克患者容量反应性显著相关。
- ROC曲线分析:∆VTI的AUC 0.952(敏感度1.00、特异度0.84、阈值0.128),∆LVS的AUC 0.802(敏感度0.73、特异度0.91、阈值0.129),∆RVS的AUC 0.822(敏感度0.81、特异度0.76、阈值0.130),TAPSE的AUC 0.713(敏感度0.83、特异度0.67、阈值13.9 mm)。
证据类型、等级与局限
- 证据类型:超声诊断准确性研究(样本量33例)。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为组织多普勒超声评估二尖瓣和三尖瓣环收缩期峰值流速呼吸变异率可能是简单评估脓毒性休克患者容量反应性的可行、可靠方法。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
Objective: The aim of this study was to evaluate the reliability and feasibility of pulse Doppler measurements of peak velocity respiratory variability of mitral and tricuspid valve rings during systole as new dynamic indicators of fluid responsiveness in patients with septic shock. Methods: Transthoracic echocardiography (TTE) was performed to measure the respiratory variability of aortic velocity-time integral (∆VTI), respiratory variability of tricuspid annulus systolic peak velocity (∆RVS), respiratory variability of mitral annulus systolic peak velocity (∆LVS), and other related indicators. Fluid responsiveness was defined as a 10% increase in cardiac output after fluid expansion, assessed by TTE. Results: A total of 33 patients with septic shock were enrolled in this study. First, there was no significant difference in the population characteristics between the fluid responsiveness positive group (n = 17) and the fluid responsiveness negative group (n = 16) ( P > 0.05). Second, Pearson correlation test showed that ∆RVS, ∆LVS, and TAPSE with the relative increase in cardiac output after fluid expansion ( R = 0.55, P = 0.001; R = 0.40, P = 0.02; R = 0.36, P = 0.041). Third, multiple logistic regression analysis demonstrated that ∆RVS, ∆LVS, and TAPSE were significantly correlated with fluid responsiveness in patients with septic shock. Fourth, receiver operating characteristic (ROC) curve analysis revealed that ∆VTI, ∆LVS, ∆RVS, and TAPSE had good predictive ability for fluid responsiveness in patients with septic shock. The area under the curve (AUC) of ∆VTI, ∆LVS, ∆RVS, and TAPSE for predicting fluid responsiveness was 0.952, 0.802, 0.822, and 0.713, respectively. The sensitivity (Se) values were 1.00, 0.73, 0.81, and 0.83, whereas the specificity (Sp) values were 0.84, 0.91, 0.76, and 0.67, respectively. The optimal thresholds were 0.128, 0.129, 0.130, and 13.9 mm, respectively. Conclusion: Tissue Doppler ultrasound evaluation of respiratory variability of mitral and tricuspid annular peak systolic velocity could be a feasible and reliable method for the simple assessment of fluid responsiveness in patients with septic shock.
参考来源
- Ma Q, Ding C, Jiang F, et al. RESPIRATORY VARIABILITY OF VALVULAR PEAK SYSTOLIC VELOCITY AS A NEW INDICATOR OF FLUID RESPONSIVENESS IN PATIENTS WITH SEPTIC SHOCK. Shock. 2023. PMID: 37179247. doi:10.1097/SHK.0000000000002142
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。