文献速递心脑血管急症呼吸衰竭与机械通气

长期使用者急性使用电子尼古丁传送系统与可燃香烟的心血管和肺部反应

Cardiovascular and Pulmonary Responses to Acute Use of Electronic Nicotine Delivery Systems and Combustible Cigarettes in Long-Term Users.
PubMed 文献 · Chest · 2023-04-10
一句话结论长期使用电子烟者急性使用15分钟后血压、心率升高、心率变异性降低、血管收缩、运动耐量下降及气流受限加重,程度与吸烟者相似。

该观察性激发研究纳入395人,包括 exclusive ENDS 使用者164人、 exclusive 吸烟者117人及不吸烟不 vaping 对照114人,比较15分钟产品使用前后心血管和肺部反应。使用后,ENDS 使用者较对照者收缩压升高5.6 mm Hg vs 2.3 mm Hg、舒张压升高4.2 mm Hg vs 2.0 mm Hg、心率升高4.8次/分 vs -1.3次/分,肱动脉直径减少-0.011 cm vs -0.006 cm,心率变异性降低-7.2 ms vs 3.6 ms,FEV1下降-4.1 vs -1.1,运动参数如METs调整均差1.28 METs、60秒心率恢复调整均差2.9次/分均劣于对照。作者结论认为电子烟急性使用可导致血压、心率、心率变异性恶化及血管收缩、运动耐量受损和气流阻塞加重。

要点

  • 长期ENDS使用者急性使用15分钟后收缩压升高5.6 mm Hg(95%CI 4.4-6.8),对照者升高2.3 mm Hg(95%CI 0.8-3.8),P=0.001。
  • ENDS使用者心率升高4.8次/分(95%CI 4.0-5.6),对照者降低-1.3次/分(95%CI -2.2至-0.3),P<0.001。
  • ENDS使用者肱动脉直径减少-0.011 cm(95%CI -0.013至0.009),对照者减少-0.006 cm(95%CI -0.004至-0.009),P=0.003。
  • ENDS使用者FEV1下降-4.1(95%CI -5.4至-2.8),对照者下降-1.1(95%CI -2.7至0.6),P=0.005。
  • ENDS使用者运动参数劣于对照者:METs调整均差1.28 METs(95%CI 0.73-1.83),P<0.001;60秒心率恢复调整均差2.9次/分(95%CI 0.7-5.0),P=0.008。

适用人群与场景

  • 长期使用含尼古丁产品的成年人: exclusive ENDS 使用者(呼出气一氧化碳<5 ppm,尿NicCheck I阳性率82%,使用第四代ENDS)164人; exclusive 吸烟者(一氧化碳>5 ppm,尿NicCheck I阳性)117人;不吸烟不 vaping 对照者(一氧化碳<5 ppm,尿NicCheck I阴性)114人。
  • 研究场景为观察性激发研究,比较15分钟产品使用前后的急性反应。

诊断标准与关键阈值

  • ENDS使用者定义:呼出气一氧化碳水平<5 ppm,尿NicCheck I(Mossman Associates)阳性率82%,使用第四代ENDS。
  • 吸烟者定义:呼出气一氧化碳水平>5 ppm,尿NicCheck I阳性。
  • 对照者定义:呼出气一氧化碳水平<5 ppm,尿NicCheck I阴性。

研究设计与关键结果

  • 研究类型:观察性激发研究,纳入395人(ENDS使用者164人、吸烟者117人、对照者114人)。
  • 15分钟产品激发期间,吸烟者吸烟支数中位数14.0口(IQR 9.3口),ENDS使用者9.0口(IQR 7.5口),P<0.001。
  • 使用后较对照者,ENDS使用者收缩压调整均差升高5.6 mm Hg(95%CI 4.4-6.8)vs 2.3 mm Hg(95%CI 0.8-3.8),P=0.001;舒张压升高4.2 mm Hg(95%CI 3.3-5.0)vs 2.0 mm Hg(95%CI 1.1-3.0),P=0.003;心率升高4.8次/分(95%CI 4.0-5.6)vs -1.3次/分(95%CI -2.2至-0.3),P<0.001。
  • ENDS使用者较对照者肱动脉直径减少-0.011 cm(95%CI -0.013至0.009)vs -0.006 cm(95%CI -0.004至-0.009),P=0.003;时域心率变异性降低-7.2 ms(95%CI -10.5至-3.7)vs 3.6 ms(95%CI 1.6-9.3),P=0.001;FEV1下降-4.1(95%CI -5.4至-2.8)vs -1.1(95%CI -2.7至0.6),P=0.005;上述指标与吸烟者相似。
  • ENDS使用者所有运动参数均劣于对照者,尤其是METs调整均差1.28 METs(95%CI 0.73-1.83),P<0.001;60秒心率恢复调整均差2.9次/分(95%CI 0.7-5.0),P=0.008。

证据类型、等级与局限

  • 证据类型:观察性激发研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者结论认为,与对照者相比,ENDS使用者vaping后出现血压、心率和心率变异性急性恶化,以及血管收缩、运动耐量受损和气流阻塞加重。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: The acute cardiovascular and pulmonary effects of contemporary electronic nicotine delivery systems (ENDS) in long-term users are not known.

RESEARCH QUESTION: What are the cardiovascular and pulmonary responses to an acute 15-min product use challenge with ENDS and combustible cigarettes in regular nicotine-containing product users compared with control participants who do not use tobacco or vape?

STUDY DESIGN AND METHODS: Observational challenge study before and after nicotine-containing product use of 395 individuals who used ENDS exclusively (n = 164; exhaled carbon monoxide level, < 5 parts per million [ppm]; positive urine NicCheck I [Mossman Associates] results, 82%; fourth-generation ENDS), participants who smoked cigarettes exclusively (n = 117; carbon monoxide level, > 5 ppm; positive urine NicCheck I results), and control participants (n = 114; carbon monoxide level, < 5 ppm; negative urine NicCheck I results).

RESULTS: During the 15-min product challenge, cigarette users took a median of 14.0 puffs (interquartile range [IQR], 9.3 puffs); ENDS users took 9.0 puffs (IQR, 7.5 puffs; P < .001). After product challenge, compared with control participants, ENDS users showed greater increases in adjusted mean differences in systolic BP (5.6 mm Hg [95% CI, 4.4-6.8 mm Hg] vs 2.3 mm Hg [95% CI, 0.8-3.8 mm Hg]; P = .001), diastolic BP (4.2 mm Hg [95% CI, 3.3-5.0 mm Hg] vs 2.0 mm Hg [95% CI, 1.1-3.0 mm Hg; P = .003), and heart rate (4.8 beats/min [95% CI, 4.0-5.6 beats/min] vs -1.3 beats/min [95% CI, -2.2 to -0.3 beats/min]; P < .001) and greater reductions in brachial artery diameter (-0.011 cm [95% CI, -0.013 to 0.009 cm] vs -0.006 cm [95% CI, -0.004 to -0.009 cm]; P = .003), time-domain heart rate variability (-7.2 ms [95% CI, -10.5 to -3.7 ms] vs 3.6 ms [95% CI, 1.6-9.3 ms]; P = .001), and FEV1 (ENDS: -4.1 [95% CI, -5.4 to -2.8] vs control participants: -1.1 [95% CI, -2.7 to 0.6]; P = .005) with values similar to those of cigarette users. ENDS users performed worse than control participants on all exercise parameters, notably metabolic equivalents (METs; adjusted mean difference, 1.28 METs [95% CI, 0.73-1.83 METs]; P < .001) and 60-s heart rate recovery (adjusted mean difference, 2.9 beats/min [95% CI, 0.7-5.0 beats/min]; P = .008).

INTERPRETATION: ENDS users had acute worsening of blood pressure, heart rate, and heart rate variability, as well as vasoconstriction, impaired exercise tolerance, and increased airflow obstruction after vaping, compared to control participants.

TRIAL REGISTRY: ClinicalTrials.gov; No.: NCT03863509; URL: www.

CLINICALTRIALS: gov.

来源:Chest,查看原文。版权归原作者所有。

参考来源

  1. Tattersall MC, Hughey CM, Piasecki TM, et al. Cardiovascular and Pulmonary Responses to Acute Use of Electronic Nicotine Delivery Systems and Combustible Cigarettes in Long-Term Users. Chest. 2023. PMID: 37044158. doi:10.1016/j.chest.2023.03.047

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。