文献速递复苏、休克与脓毒症重症综合管理与镇静镇痛

降低呼气末正压诱导的心输出量增加可可靠检测容量反应性:PEEP试验研究

The increase in cardiac output induced by a decrease in positive end-expiratory pressure reliably detects volume responsiveness: the PEEP-test study.
PubMed 文献 · Crit Care · 2023-04-09
一句话结论对PEEP≥10 cmH2O的机械通气患者,将PEEP降至5 cmH2O持续1分钟,心指数增加>8.6%可可靠检测容量反应性。

该前瞻性研究纳入64例PEEP≥10 cmH2O且无自主呼吸的机械通气患者,以被动抬腿试验(PLR)中脉搏轮廓心指数(CI)增加≥10%定义为容量反应性,31例为容量反应者。PEEP试验将PEEP从高水平降至5 cmH2O持续1分钟;容量反应者PEEP试验期间CI显著增加16%(12-20%)(从2.4±0.7升至2.9±0.9 L/min/m2,p<0.0001),容量无反应者CI增加6%(3-8%)。PEEP试验中CI增加>8.6%预测容量反应性的敏感度为96.8%(95%CI 83.3-99.9%)、特异度为84.9%(95%CI 68.1-94.9%),ROC曲线下面积为0.94(95%CI 0.85-0.98)(p<0.0001 vs. 0.5)。

要点

  • 对PEEP≥10 cmH2O且无自主呼吸的机械通气患者,PEEP试验(降至5 cmH2O持续1分钟)中CI增加>8.6%预测容量反应性,敏感度96.8%、特异度84.9%。
  • 容量反应者PEEP试验期间CI增加16%(12-20%),从2.4±0.7升至2.9±0.9 L/min/m2(p<0.0001);容量无反应者仅增加6%(3-8%)。
  • 容量反应者PLR期间CI中位增加14%(11-16%),容量无反应者PLR期间CI仅增加2%(1-5%)。
  • PEEP试验预测容量反应性的ROC曲线下面积为0.94(95%CI 0.85-0.98)(p<0.0001 vs. 0.5)。
  • PLR与PEEP试验诱导的CI变化之间的Spearman相关系数为0.76(95%CI 0.63-0.85,p<0.0001)。

适用人群与场景

  • 机械通气患者,PEEP≥10 cmH2O(高水平)且无自主呼吸,前瞻性纳入。

诊断标准与关键阈值

  • 容量反应性定义:PLR试验中脉搏轮廓心指数(CI)增加≥10%为阳性。
  • PEEP试验:将PEEP从高水平降至5 cmH2O持续1分钟。
  • PEEP试验中CI增加>8.6%预测容量反应性,敏感度96.8%(95%CI 83.3-99.9%)、特异度84.9%(95%CI 68.1-94.9%)。

处置流程与药物剂量

  • PEEP试验操作:将PEEP从高水平降至5 cmH2O,持续1分钟,期间用PiCCO2监测脉搏轮廓CI。

研究设计与关键结果

  • 前瞻性研究纳入64例机械通气患者,其中31例为容量反应者。
  • PLR期间CI中位增加14%(11-16%);基线PEEP中位12(10-15)cmH2O,PEEP试验导致PEEP中位下降7(5-10)cmH2O,容量反应者与无反应者之间无差异。
  • 容量反应者PEEP试验诱导CI显著增加16%(12-20%)(从2.4±0.7升至2.9±0.9 L/min/m2,p<0.0001)。
  • 容量无反应者PLR和PEEP试验分别使CI增加2%(1-5%)和6%(3-8%)。
  • PEEP试验中CI增加>8.6%预测容量反应性的敏感度96.8%(95%CI 83.3-99.9%)、特异度84.9%(95%CI 68.1-94.9%);ROC曲线下面积0.94(95%CI 0.85-0.98)(p<0.0001 vs. 0.5)。
  • PLR与PEEP试验诱导的CI变化之间的Spearman相关系数0.76(95%CI 0.63-0.85,p<0.0001)。

证据类型、等级与局限

  • 证据类型:前瞻性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,在PEEP≥10 cmH2O的机械通气患者中,PEEP试验(将PEEP降至5 cmH2O)期间CI增加>8.6%可可靠检测容量反应性。

指南或共识出处

  • 试验注册:ClinicalTrial.gov(NCT 04,023,786),注册日期2019年7月18日;伦理委员会批准CPP Est III(编号2018-A01599-46)。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: In patients on mechanical ventilation, positive end-expiratory pressure (PEEP) can decrease cardiac output through a decrease in cardiac preload and/or an increase in right ventricular afterload. Increase in central blood volume by fluid administration or passive leg raising (PLR) may reverse these phenomena through an increase in cardiac preload and/or a reopening of closed lung microvessels. We hypothesized that a transient decrease in PEEP (PEEP-test) may be used as a test to detect volume responsiveness.

METHODS: Mechanically ventilated patients with PEEP ≥ 10 cmH2O ("high level") and without spontaneous breathing were prospectively included. Volume responsiveness was assessed by a positive PLR-test, defined as an increase in pulse-contour-derived cardiac index (CI) during PLR ≥ 10%. The PEEP-test consisted in reducing PEEP from the high level to 5 cmH2O for one minute. Pulse-contour-derived CI (PiCCO2) was monitored during PLR and the PEEP-test.

RESULTS: We enrolled 64 patients among whom 31 were volume responsive. The median increase in CI during PLR was 14% (11-16%). The median PEEP at baseline was 12 (10-15) cmH2O and the PEEP-test resulted in a median decrease in PEEP of 7 (5-10) cmH2O, without difference between volume responsive and unresponsive patients. Among volume responsive patients, the PEEP-test induced a significant increase in CI of 16% (12-20%) (from 2.4 ± 0.7 to 2.9 ± 0.9 L/min/m2, p < 0.0001) in comparison with volume unresponsive patients. In volume unresponsive patients, PLR and the PEEP-test increased CI by 2% (1-5%) and 6% (3-8%), respectively. Volume responsiveness was predicted by an increase in CI > 8.6% during the PEEP-test with a sensitivity of 96.8% (95% confidence interval (95%CI): 83.3-99.9%) and a specificity of 84.9% (95%CI 68.1-94.9%). The area under the receiver operating characteristic curve of the PEEP-test for detecting volume responsiveness was 0.94 (95%CI 0.85-0.98) (p < 0.0001 vs. 0.5). Spearman's correlation coefficient between the changes in CI induced by PLR and the PEEP-test was 0.76 (95%CI 0.63-0.85, p < 0.0001).

CONCLUSIONS: A CI increase > 8.6% during a PEEP-test, which consists in reducing PEEP to 5 cmH2O, reliably detects volume responsiveness in mechanically ventilated patients with a PEEP ≥ 10 cmH2O. Trial registration ClinicalTrial.gov (NCT 04,023,786). Registered July 18, 2019. Ethics Committee approval CPP Est III (N° 2018-A01599-46).

来源:Crit Care,查看原文。版权归原作者所有。

参考来源

  1. Lai C, Shi R, Beurton A, et al. The increase in cardiac output induced by a decrease in positive end-expiratory pressure reliably detects volume responsiveness: the PEEP-test study. Crit Care. 2023. PMID: 37031182. doi:10.1186/s13054-023-04424-7

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。