文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

插管低氧血症患者呼吸驱动增加的临床危险因素

Clinical risk factors for increased respiratory drive in intubated hypoxemic patients.
PubMed 文献 · Crit Care · 2023-04-11
一句话结论插管低氧血症患者中,双侧浸润、低PaO2/FiO2、高通气比、低pHa及低PEEP与呼吸驱动(P0.1)升高独立相关,镇静深度与药物不影响驱动。

该研究基于多中心试验的生理学数据集,纳入217例压力支持通气的插管低氧血症患者,分析第1天P0.1与临床危险因素的独立相关性。结果显示,双侧浸润(IR 1.233,95%CI 1.047-1.451,p=0.012)、较低PaO2/FiO2(IR 0.998,95%CI 0.997-0.999,p=0.004)、较高通气比(IR 1.538,95%CI 1.267-1.867,p<0.001)、较低pHa(IR 0.104,95%CI 0.024-0.464,p=0.003)与较高P0.1独立相关;较高PEEP与较低P0.1相关(IR 0.951,95%CI 0.921-0.982,p=0.002)。镇静深度和药物类型与P0.1无关联。提示呼吸驱动增加具有多因素性质,肺水肿程度、通气/灌注不匹配、酸血症和低PEEP是床旁可识别的驱动升高因素。

要点

  • 双侧肺浸润患者P0.1升高的IR为1.233(95%CI 1.047-1.451,p=0.012),单侧浸润者驱动相对较低。
  • PaO2/FiO2每降低,P0.1升高(IR 0.998,95%CI 0.997-0.999,p=0.004),氧合越差驱动越高。
  • 通气比升高与P0.1升高独立相关(IR 1.538,95%CI 1.267-1.867,p<0.001),提示通气/灌注不匹配增加驱动。
  • pHa降低与P0.1升高独立相关(IR 0.104,95%CI 0.024-0.464,p=0.003),酸血症时驱动增加。
  • 较高PEEP与较低P0.1相关(IR 0.951,95%CI 0.921-0.982,p=0.002);镇静深度和药物类型与P0.1无关联。

适用人群与场景

  • 插管低氧血症患者,来自多中心试验中接受压力支持(PS)通气者。
  • 纳入同时评估第1天P0.1(气道闭合0.1秒时吸气气道压下降)和呼吸驱动增加危险因素的患者。

诊断标准与关键阈值

  • 呼吸驱动以P0.1评估,即气道闭合0.1秒时吸气气道压下降。

研究设计与关键结果

  • 研究类型:多中心试验的生理学数据集分析;样本量217例插管低氧血症患者,接受压力支持通气。
  • 与较高P0.1独立相关的因素:双侧浸润(IR 1.233,95%CI 1.047-1.451,p=0.012);较低PaO2/FiO2(IR 0.998,95%CI 0.997-0.999,p=0.004);较高通气比(IR 1.538,95%CI 1.267-1.867,p<0.001);较低pHa(IR 0.104,95%CI 0.024-0.464,p=0.003)。
  • 较高PEEP与较低P0.1相关(IR 0.951,95%CI 0.921-0.982,p=0.002)。
  • 镇静深度(RASS评分)和药物类型与P0.1无关联。

证据类型、等级与局限

  • 证据类型:基于多中心试验生理学数据集的分析。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,插管低氧血症患者呼吸驱动增加具有多因素性质,肺水肿程度、通气/灌注不匹配、酸血症和低PEEP是可床旁识别的驱动升高相关因素,而镇静策略不影响驱动。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: There is very limited evidence identifying factors that increase respiratory drive in hypoxemic intubated patients. Most physiological determinants of respiratory drive cannot be directly assessed at the bedside (e.g., neural inputs from chemo- or mechano-receptors), but clinical risk factors commonly measured in intubated patients could be correlated with increased drive. We aimed to identify clinical risk factors independently associated with increased respiratory drive in intubated hypoxemic patients.

METHODS: We analyzed the physiological dataset from a multicenter trial on intubated hypoxemic patients on pressure support (PS). Patients with simultaneous assessment of the inspiratory drop in airway pressure at 0.1-s during an occlusion (P0.1) and risk factors for increased respiratory drive on day 1 were included. We evaluated the independent correlation of the following clinical risk factors for increased drive with P0.1: severity of lung injury (unilateral vs. bilateral pulmonary infiltrates, PaO2/FiO2, ventilatory ratio); arterial blood gases (PaO2, PaCO2 and pHa); sedation (RASS score and drug type); SOFA score; arterial lactate; ventilation settings (PEEP, level of PS, addition of sigh breaths).

RESULTS: Two-hundred seventeen patients were included. Clinical risk factors independently correlated with higher P0.1 were bilateral infiltrates (increase ratio [IR] 1.233, 95%CI 1.047-1.451, p = 0.012); lower PaO2/FiO2 (IR 0.998, 95%CI 0.997-0.999, p = 0.004); higher ventilatory ratio (IR 1.538, 95%CI 1.267-1.867, p < 0.001); lower pHa (IR 0.104, 95%CI 0.024-0.464, p = 0.003). Higher PEEP was correlated with lower P0.1 (IR 0.951, 95%CI 0.921-0.982, p = 0.002), while sedation depth and drugs were not associated with P0.1.

CONCLUSIONS: Independent clinical risk factors for higher respiratory drive in intubated hypoxemic patients include the extent of lung edema and of ventilation-perfusion mismatch, lower pHa, and lower PEEP, while sedation strategy does not affect drive. These data underline the multifactorial nature of increased respiratory drive.

来源:Crit Care,查看原文。版权归原作者所有。

参考来源

  1. Spinelli E, Pesenti A, Slobod D, et al. Clinical risk factors for increased respiratory drive in intubated hypoxemic patients. Crit Care. 2023. PMID: 37041553. doi:10.1186/s13054-023-04402-z

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。