文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛心脑血管急症

脑损伤患者机械能的利用及其与临床结局的关联:ENIO试验的二次分析

Utilization of mechanical power and associations with clinical outcomes in brain injured patients: a secondary analysis of the extubation strategies in neuro-intensive care unit patients and associations with outcome (ENIO) trial.
PubMed 文献 · Crit Care · 2023-04-20
一句话结论急性脑损伤机械通气患者第一周高机械能与住院死亡、再插管、气管切开及中重度ARDS相关,独立于P/F比值和神经严重程度。

该研究为前瞻性多中心观察性队列ENIO试验(NCT03400904)的预先计划的二次分析,纳入1217例成人急性脑损伤(插管前GCS≤12)且机械通气≥24小时的患者,覆盖18个国家62个ICU。住院死亡11%(n=139),HD7前拔管44%(n=536)其中20%(107/536)再插管,28%(n=340)行气管切开,9%(n=114)发生ARDS。校正同日P/F比值、BMI和神经严重程度后,HD1、HD3、HD7机械能与住院死亡、再插管和气管切开独立相关,且与中重度ARDS发生相关。作者认为优化通气设置以限制机械能的潜在获益值得进一步研究。

要点

  • 在1217例急性脑损伤机械通气患者中,HD1机械能中位数11.9 J/min,HD3为13 J/min,HD7为14 J/min。
  • 校正P/F比值、BMI和神经严重程度后,HD1机械能17 J/min(对比中位数11.9 J/min)与住院死亡独立相关,aRR 1.22(95%CI 1.14-1.30)。
  • HD1机械能与再插管独立相关,aRR 1.64(95%CI 1.57-1.72);HD7机械能与气管切开独立相关,aRR 1.53(95%CI 1.18-1.99)。
  • HD1机械能与中重度ARDS发生独立相关,aRR 2.07(95%CI 1.56-2.78);HD3为1.76(95%CI 1.41-2.22)。
  • ARDS患者机械能总体更高,尤其是ARDS严重程度更高的患者。

适用人群与场景

  • 成人急性脑损伤患者,插管前格拉斯哥昏迷评分(GCS)≤12,且需要机械通气≥24小时。
  • 来自18个国家62个重症监护病房的前瞻性多中心观察性队列。

诊断标准与关键阈值

  • 急性脑损伤定义:插管前GCS≤12。
  • 机械通气时长要求:≥24小时。

研究设计与关键结果

  • 研究类型:前瞻性、多中心、观察性队列研究(ENIO,NCT03400904)的预先计划的二次分析。
  • 样本量:1217例,平均年龄51.2岁(SD 18.1),66%男性,平均BMI 26.3(SD 5.18),来自18个国家62个ICU。
  • 主要结局:住院死亡11%(n=139),HD7前拔管44%(n=536)其中再插管20%(107/536),气管切开28%(n=340),ARDS 9%(n=114)。
  • 机械能中位数:HD1 11.9 J/min(IQR 9.2-15.1),HD3 13 J/min(IQR 10-17),HD7 14 J/min(IQR 11-20)。
  • 校正同日P/F比值、BMI和神经严重程度后,HD1机械能17 J/min(对比中位数11.9 J/min)与住院死亡独立相关,aRR 1.22(95%CI 1.14-1.30);HD3 aRR 1.38(95%CI 1.23-1.53)。
  • HD1机械能与再插管独立相关,aRR 1.64(95%CI 1.57-1.72);HD7机械能与气管切开独立相关,aRR 1.53(95%CI 1.18-1.99)。
  • HD1机械能与中重度ARDS发生独立相关,aRR 2.07(95%CI 1.56-2.78);HD3 aRR 1.76(95%CI 1.41-2.22)。

证据类型、等级与局限

  • 证据类型:前瞻性多中心观察性队列研究的二次分析。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,优化通气设置以限制机械能的潜在获益值得进一步研究。
  • 急性脑损伤机械通气患者第一周高机械能与不良临床结局相关,独立于P/F比值和神经严重程度;该关联为观察性结果。

指南或共识出处

  • ENIO试验(NCT03400904)的二次分析,发表于Crit Care。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: There is insufficient evidence to guide ventilatory targets in acute brain injury (ABI). Recent studies have shown associations between mechanical power (MP) and mortality in critical care populations. We aimed to describe MP in ventilated patients with ABI, and evaluate associations between MP and clinical outcomes.

METHODS: In this preplanned, secondary analysis of a prospective, multi-center, observational cohort study (ENIO, NCT03400904), we included adult patients with ABI (Glasgow Coma Scale ≤ 12 before intubation) who required mechanical ventilation (MV) ≥ 24 h. Using multivariable log binomial regressions, we separately assessed associations between MP on hospital day (HD)1, HD3, HD7 and clinical outcomes: hospital mortality, need for reintubation, tracheostomy placement, and development of acute respiratory distress syndrome (ARDS).

RESULTS: We included 1217 patients (mean age 51.2 years [SD 18.1], 66% male, mean body mass index [BMI] 26.3 [SD 5.18]) hospitalized at 62 intensive care units in 18 countries. Hospital mortality was 11% (n = 139), 44% (n = 536) were extubated by HD7 of which 20% (107/536) required reintubation, 28% (n = 340) underwent tracheostomy placement, and 9% (n = 114) developed ARDS. The median MP on HD1, HD3, and HD7 was 11.9 J/min [IQR 9.2-15.1], 13 J/min [IQR 10-17], and 14 J/min [IQR 11-20], respectively. MP was overall higher in patients with ARDS, especially those with higher ARDS severity. After controlling for same-day pressure of arterial oxygen/fraction of inspired oxygen (P/F ratio), BMI, and neurological severity, MP at HD1, HD3, and HD7 was independently associated with hospital mortality, reintubation and tracheostomy placement. The adjusted relative risk (aRR) was greater at higher MP, and strongest for: mortality on HD1 (compared to the HD1 median MP 11.9 J/min, aRR at 17 J/min was 1.22, 95% CI 1.14-1.30) and HD3 (1.38, 95% CI 1.23-1.53), reintubation on HD1 (1.64; 95% CI 1.57-1.72), and tracheostomy on HD7 (1.53; 95%CI 1.18-1.99). MP was associated with the development of moderate-severe ARDS on HD1 (2.07; 95% CI 1.56-2.78) and HD3 (1.76; 95% CI 1.41-2.22).

CONCLUSIONS: Exposure to high MP during the first week of MV is associated with poor clinical outcomes in ABI, independent of P/F ratio and neurological severity. Potential benefits of optimizing ventilator settings to limit MP warrant further investigation.

来源:Crit Care,查看原文。版权归原作者所有。

参考来源

  1. Wahlster S, Sharma M, Taran S, et al. Utilization of mechanical power and associations with clinical outcomes in brain injured patients: a secondary analysis of the extubation strategies in neuro-intensive care unit patients and associations with outcome (ENIO) trial. Crit Care. 2023. PMID: 37081474. doi:10.1186/s13054-023-04410-z

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。