文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛心脑血管急症

无肺损伤的急性脑损伤患者中肺保护性通气的神经与呼吸效应:脑通气单中心随机干预研究

Neurological and respiratory effects of lung protective ventilation in acute brain injury patients without lung injury: brain vent, a single centre randomized interventional study.
PubMed 文献 · Crit Care · 2023-03-20
一句话结论无肺损伤的急性脑损伤患者中,大多数患者对肺保护性通气(低潮气量+高PEEP)无颅内压或脑自动调节不良影响,但近四分之一患者颅内压升高超过安全上限而需中断干预。

该前瞻性交叉随机研究纳入30例颅内压正常且无肺损伤的急性脑损伤插管患者,随机接受低潮气量(6 ml/kg预测体重)联合低PEEP(5 cmH2O)或高PEEP(12 cmH2O),每次干预间恢复基线通气(潮气量9 ml/kg预测体重、PEEP 5 cmH2O)。最终分析27例(脑出血、创伤性脑损伤、蛛网膜下腔出血),其中6例达到安全上限(颅内压>22 mmHg持续>5分钟)而需中断至少一次干预。未中断干预者中,从基线到低潮气量/低PEEP和低潮气量/高PEEP的颅内压变化分别为2.2 mmHg和2.3 mmHg,认为临床不相关;干预未显著影响脑自动调节或氧合。中断事件与高基线颅内压(p<0.001)、低脑代偿储备(p<0.01)和机械功率(p<0.05)相关;两种干预的跨肺驱动压均为5±2 cmH2O,通过调整呼吸频率将动脉血二氧化碳分压维持在34-36 mmHg,故二氧化碳变化与颅内压升高无关。

要点

  • 无肺损伤的急性脑损伤患者中,大多数对低潮气量(6 ml/kg预测体重)联合高PEEP(12 cmH2O)耐受良好,颅内压变化小(低PEEP组2.2 mmHg、高PEEP组2.3 mmHg),临床不相关。
  • 6/27例(近四分之一)患者颅内压升高超过安全上限(>22 mmHg持续>5分钟),需中断至少一次干预。
  • 中断事件与高基线颅内压(p<0.001)、低脑代偿储备(p<0.01)和机械功率(p<0.05)相关,可用于个体化通气设置。
  • 干预未显著影响脑自动调节或氧合;跨肺驱动压两种干预均为5±2 cmH2O。
  • 通过调整呼吸频率将动脉血二氧化碳分压维持在34-36 mmHg,二氧化碳变化与颅内压升高无关。

适用人群与场景

  • 急性脑损伤(脑出血、创伤性脑损伤、蛛网膜下腔出血)插管患者,颅内压正常且无肺损伤。

诊断标准与关键阈值

  • 安全上限:颅内压>22 mmHg持续>5分钟需中断干预。
  • 基线通气:潮气量9 ml/kg预测体重、PEEP 5 cmH2O;低潮气量:6 ml/kg预测体重;低PEEP:5 cmH2O;高PEEP:12 cmH2O。
  • 动脉血二氧化碳分压目标范围34-36 mmHg,通过调整呼吸频率维持。

处置流程与药物剂量

  • 随机接受低潮气量(6 ml/kg预测体重)联合低PEEP(5 cmH2O)或高PEEP(12 cmH2O),每次干预间恢复基线通气(潮气量9 ml/kg预测体重、PEEP 5 cmH2O)。
  • 持续监测气道压和跨肺压评估呼吸力学;通过外部脑室引流或脑实质探头记录颅内压。
  • 颅内压>22 mmHg持续>5分钟时中断干预。

红旗征与不能漏的情况

  • 颅内压>22 mmHg持续>5分钟需中断干预。
  • 高基线颅内压(p<0.001)、低脑代偿储备(p<0.01)和机械功率(p<0.05)与干预中断事件相关。

研究设计与关键结果

  • 前瞻性交叉随机研究纳入30例,分析27例(脑出血、创伤性脑损伤、蛛网膜下腔出血),6例达到安全上限需中断至少一次干预。
  • 未中断干预者中,从基线到低潮气量/低PEEP和低潮气量/高PEEP的颅内压变化分别为2.2 mmHg和2.3 mmHg,临床不相关。
  • 干预未显著影响脑自动调节或氧合。
  • 中断事件与高基线颅内压(p<0.001)、低脑代偿储备(p<0.01)和机械功率(p<0.05)相关。
  • 两种干预的跨肺驱动压均为5±2 cmH2O;动脉血二氧化碳分压维持在34-36 mmHg,二氧化碳变化与颅内压升高无关。

证据类型、等级与局限

  • 证据类型:前瞻性、交叉、单中心随机干预研究(NCT03278769,注册于2017年9月12日)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为基线颅内压、脑代偿储备和机械功率可预测肺保护性通气的潜在有害效应,并可用于个体化呼吸机设置。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

INTRODUCTION: Lung protective ventilation (LPV) comprising low tidal volume (VT) and high positive end-expiratory pressure (PEEP) may compromise cerebral perfusion in acute brain injury (ABI). In patients with ABI, we investigated whether LPV is associated with increased intracranial pressure (ICP) and/or deranged cerebral autoregulation (CA), brain compensatory reserve and oxygenation.

METHODS: In a prospective, crossover study, 30 intubated ABI patients with normal ICP and no lung injury were randomly assigned to receive low VT [6 ml/kg/predicted (pbw)]/at either low (5 cmH2O) or high PEEP (12 cmH2O). Between each intervention, baseline ventilation (VT 9 ml/kg/pbw and PEEP 5 cmH2O) were resumed. The safety limit for interruption of the intervention was ICP above 22 mmHg for more than 5 min. Airway and transpulmonary pressures were continuously monitored to assess respiratory mechanics. We recorded ICP by using external ventricular drainage or a parenchymal probe. CA and brain compensatory reserve were derived from ICP waveform analysis.

RESULTS: We included 27 patients (intracerebral haemorrhage, traumatic brain injury, subarachnoid haemorrhage), of whom 6 reached the safety limit, which required interruption of at least one intervention. For those without intervention interruption, the ICP change from baseline to "low VT/low PEEP" and "low VT/high PEEP" were 2.2 mmHg and 2.3 mmHg, respectively, and considered clinically non-relevant. None of the interventions affected CA or oxygenation significantly. Interrupted events were associated with high baseline ICP (p < 0.001), low brain compensatory reserve (p < 0.01) and mechanical power (p < 0.05). The transpulmonary driving pressure was 5 ± 2 cmH2O in both interventions. Partial arterial pressure of carbon dioxide was kept in the range 34-36 mmHg by adjusting the respiratory rate, hence, changes in carbon dioxide were not associated with the increase in ICP.

CONCLUSIONS: The present study found that most patients did not experience any adverse effects of LPV, neither on ICP nor CA. However, in almost a quarter of patients, the ICP rose above the safety limit for interrupting the interventions. Baseline ICP, brain compensatory reserve, and mechanical power can predict a potentially deleterious effect of LPV and can be used to personalize ventilator settings. Trial registration NCT03278769 . Registered September 12, 2017.

来源:Crit Care,查看原文。版权归原作者所有。

参考来源

  1. Beqiri E, Smielewski P, Guérin C, et al. Neurological and respiratory effects of lung protective ventilation in acute brain injury patients without lung injury: brain vent, a single centre randomized interventional study. Crit Care. 2023. PMID: 36941683. doi:10.1186/s13054-023-04383-z

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。