文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

机械通气COVID-19急性呼吸窘迫综合征患者呼气末正压引起的气道驱动压变化

Positive end-expiratory pressure induced changes in airway driving pressure in mechanically ventilated COVID-19 Acute Respiratory Distress Syndrome patients.
PubMed 文献 · Crit Care · 2023-03-21
一句话结论在COVID-19 ARDS患者中,基于PEEP引起的气道驱动压变化调整PEEP可行,可能有助于个体化保护性通气;多数患者所需PEEP较低,且受BMI影响。

研究纳入三家医院的184例机械通气COVID-19 ARDS患者(其中41例接受电阻抗断层成像EIT评估),初始按氧合表调整FiO2和PEEP,随后将PEEP从20 cmH2O降至6 cmH2O并逐步记录驱动压(dPaw),确定使dPaw最低的PEEP(PEEPmin_dPaw)。126例(68%)呈J型曲线(PEEPmin_dPaw 7.5±1.9 cmH2O),40例(22%)呈U型(12.2±2.6 cmH2O),18例(10%)呈倒J型(14.6±2.3 cmH2O)。倒J型患者BMI更高、基线PaO2/FiO2更低;PEEPmin_dPaw与较低的肺泡塌陷和过度膨胀比例相关。作者认为基于PEEP诱导dPaw变化的PEEP调整流程可行,可能有助于个体化保护性通气。

要点

  • 184例COVID-19 ARDS患者中,68%呈J型dPaw-PEEP曲线,使dPaw最低的PEEP为7.5±1.9 cmH2O。
  • 22%患者呈U型曲线(PEEPmin_dPaw 12.2±2.6 cmH2O),10%呈倒J型曲线(PEEPmin_dPaw 14.6±2.3 cmH2O)。
  • 倒J型曲线患者BMI更高、基线PaO2/FiO2更低。
  • PEEPmin_dPaw与较低的肺泡塌陷比例和过度膨胀比例相关(41例EIT评估)。
  • 作者认为基于PEEP诱导dPaw变化的PEEP调整流程可行,可能有助于个体化保护性通气。

适用人群与场景

  • 三家医院收治的机械通气COVID-19 ARDS患者,共184例,其中41例接受EIT评估。

诊断标准与关键阈值

  • dPaw-PEEP曲线按最低dPaw与最低PEEP、最高PEEP时dPaw的差值分为J型、倒J型或U型。

处置流程与药物剂量

  • 初始按氧合表调整FiO2和PEEP,随后将PEEP从20 cmH2O降至6 cmH2O,逐步记录dPaw,评估使dPaw最低的PEEP(PEEPmin_dPaw)。

研究设计与关键结果

  • 184例患者中,126例(68%)呈J型dPaw-PEEP曲线,PEEPmin_dPaw为7.5±1.9 cmH2O;40例(22%)呈U型,PEEPmin_dPaw为12.2±2.6 cmH2O;18例(10%)呈倒J型,PEEPmin_dPaw为14.6±2.3 cmH2O。
  • 倒J型患者BMI显著更高、基线PaO2/FiO2更低。
  • PEEPmin_dPaw与较低的肺泡塌陷比例和过度膨胀比例相关。

证据类型、等级与局限

  • 研究类型:多中心(三家医院)观察性研究;局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为基于PEEP诱导dPaw变化的PEEP调整流程可行,可能有助于个体化保护性通气;多数患者使dPaw最低所需PEEP较低,且受BMI影响。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: The profile of changes in airway driving pressure (dPaw) induced by positive-end expiratory pressure (PEEP) might aid for individualized protective ventilation. Our aim was to describe the dPaw versus PEEP curves behavior in ARDS from COVID-19 patients.

METHODS: Patients admitted in three hospitals were ventilated with fraction of inspired oxygen (FiO2) and PEEP initially adjusted by oxygenation-based table. Thereafter, PEEP was reduced from 20 until 6 cmH2O while dPaw was stepwise recorded and the lowest PEEP that minimized dPaw (PEEPmin_dPaw) was assessed. Each dPaw vs PEEP curve was classified as J-shaped, inverted-J-shaped, or U-shaped according to the difference between the minimum dPaw and the dPaw at the lowest and highest PEEP. In one hospital, hyperdistention and collapse at each PEEP were assessed by electrical impedance tomography (EIT).

RESULTS: 184 patients (41 including EIT) were studied. 126 patients (68%) exhibited a J-shaped dPaw vs PEEP profile (PEEPmin_dPaw of 7.5 ± 1.9 cmH2O). 40 patients (22%) presented a U (PEEPmin_dPaw of 12.2 ± 2.6 cmH2O) and 18 (10%) an inverted-J profile (PEEPmin_dPaw of 14,6 ± 2.3 cmH2O). Patients with inverted-J profiles had significant higher body mass index (BMI) and lower baseline partial pressure of arterial oxygen/FiO2 ratio. PEEPmin_dPaw was associated with lower fractions of both alveolar collapse and hyperinflation.

CONCLUSIONS: A PEEP adjustment procedure based on PEEP-induced changes in dPaw is feasible and may aid in individualized PEEP for protective ventilation. The PEEP required to minimize driving pressure was influenced by BMI and was low in the majority of patients.

来源:Crit Care,查看原文。版权归原作者所有。

参考来源

  1. da Cruz MR, Camilo LM, da Costa Xavier TB, et al. Positive end-expiratory pressure induced changes in airway driving pressure in mechanically ventilated COVID-19 Acute Respiratory Distress Syndrome patients. Crit Care. 2023. PMID: 36945013. doi:10.1186/s13054-023-04345-5

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。