文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

临床评分与超声膈肌评估预测神经重症监护病房拔管失败:单中心观察性研究

Clinical Scoring and Ultrasound-Based Diaphragm Assessment in Predicting Extubation Failure in Neurointensive Care Unit: A Single-Center Observational Study.
PubMed 文献 · Neurocrit Care · 2023-03-01
一句话结论在神经重症监护病房,拔管前RIS-i评分≥2分预测拔管失败特异性94%、敏感性89%,RIS-i评分是独立预测因子。

该单中心前瞻性队列纳入神经重症监护病房机械通气48小时以上后拔管的成人患者43例,拔管前测量咳嗽峰呼气流速、超声膈肌功能及临床评分(VISAGE、RIS-i),以48小时内再插管为拔管失败。15例(20.9%)拔管失败,失败者RIS-i评分更高(p<0.001)、VISAGE评分更低(p=0.043);多因素回归显示RIS-i评分是独立预测因子(OR 3.691,95%CI 1.5-8.67,p=0.004),ROC曲线下面积0.963,RIS-i≥2分预测拔管失败特异性94%、敏感性89%。作者认为RIS-i评分可预测神经重症监护病房拔管失败,联合超声膈肌测量能否提高预测准确性尚需进一步研究。

要点

  • 神经重症监护病房拔管前RIS-i评分是拔管失败的独立预测因子(OR 3.691,95%CI 1.5-8.67,p=0.004)。
  • RIS-i评分预测拔管失败的ROC曲线下面积为0.963。
  • RIS-i评分≥2分预测拔管失败特异性94%、敏感性89%。
  • 拔管失败者RIS-i评分更高(p<0.001)、VISAGE评分更低(p=0.043)。
  • 咳嗽峰呼气流速及超声膈肌 excursion 和咳嗽收缩速度在拔管失败者中更低但无统计学显著差异。

适用人群与场景

  • 单中心三级医疗中心神经重症监护病房中机械通气48小时以上后拔管的成人患者。

诊断标准与关键阈值

  • 拔管失败定义为拔管后48小时内需要再插管。
  • RIS-i评分≥2分用于预测拔管失败,特异性94%、敏感性89%。

研究设计与关键结果

  • 研究类型:单中心前瞻性队列研究;筛查193例,招募43例,15例(20.9%)发生拔管失败。
  • 拔管失败者RIS-i评分更高(p<0.001),VISAGE评分更低(p=0.043)。
  • 拔管失败者咳嗽峰呼气流速及超声膈肌 excursion 和咳嗽收缩速度更低,但无统计学显著差异。
  • 单因素分析中p<0.2的变量(RIS-i、VISAGE、膈肌咳嗽速度)进入多因素回归,RIS-i评分是独立预测因子(OR 3.691,95%CI 1.5-8.67,p=0.004)。
  • ROC分析:RIS-i的曲线下面积为0.963;RIS-i≥2分预测拔管失败特异性94%、敏感性89%。

证据类型、等级与局限

  • 证据类型:单中心前瞻性观察性队列研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为RIS-i评分可预测神经重症监护病房患者的拔管失败。
  • 作者认为在RIS-i评分基础上增加超声膈肌测量以提高预测准确性尚需进一步研究。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Patients in the neurointensive care unit (NICU) fail extubation despite successful weaning from mechanical ventilation. Parameters currently used in the general intensive care unit do not accurately predict extubation success in the NICU. In this study, peak cough expiratory flow rate, ultrasound-based diaphragm function assessment, and comprehensive clinical scoring systems were measured to determine whether these new variables, in isolation or combination, could predict extubation failure successfully in the NICU.

METHODS: All adult patients extubated after 48 h of mechanical ventilation in the NICU of a single tertiary care center were recruited into the prospective cohort. The patient's cough peak expiratory flow rate (C-PEFR), diaphragm function, and clinical scores were measured before extubation. C-PEFR was measured using a hand-held spirometer, diaphragm function (excursion, thickness fraction, and diaphragm contraction velocity on coughing) was assessed using ultrasound, and the clinical scores included the visual pursuit, swallowing, age, Glasgow Coma Scale for extubation (VISAGE) and respiratory insufficiency scale-intubated (RIS-i) scores. The patients requiring reintubation within 48 h were considered as extubation failure. Univariate and multivariate logistic regression analyses were done to identify predictors of extubation failure.

RESULTS: Of the 193 patients screened, 43 were recruited, and 15 had extubation failure (20.9%). Patients with extubation failure had higher RIS-i scores (p < 0.001) and lower VISAGE scores (p = 0.043). The C-PEFR and diaphragm function (excursions and contraction velocity on coughing) were lower in patients with extubation failure but not statistically significant. The variables with p < 0.2 in univariate analysis (RIS-i, VISAGE, and diaphragm cough velocity) were subjected to multivariate regression analysis. RIS-I score remained an independent predictor (odds ratio 3.691, 95% confidence interval 1.5-8.67, p = 0.004). In a receiver operating characteristic analysis, the area under the curve for RIS-i was 0.963. An RIS-i score of 2 or more had 94% specificity and 89% sensitivity for predicting extubation failure.

CONCLUSIONS: The RIS-i score predicts extubation failure in NICU patients. The addition of ultrasound-based diaphragm measurements to the RIS-i score to improve prediction accuracy needs further study. Clinical trial registration Clinical Trials Registry of India identifier CTRI/2021/03/031923.

来源:Neurocrit Care,查看原文。版权归原作者所有。

参考来源

  1. Hirolli D, Srinivasaiah B, Muthuchellappan R, et al. Clinical Scoring and Ultrasound-Based Diaphragm Assessment in Predicting Extubation Failure in Neurointensive Care Unit: A Single-Center Observational Study. Neurocrit Care. 2023. PMID: 36859489. doi:10.1007/s12028-023-01695-4

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。