文献速递复苏、休克与脓毒症

CLOVER3000 机械心肺复苏装置在院外心脏骤停非存活患者中的按压相关损伤:一项回顾性队列研究

Compression-associated injuries using CLOVER3000 device in non-survivor patients of OHCA: A retrospective cohort study.
PubMed 文献 · Am J Emerg Med · 2023-03-23
一句话结论在成人非创伤性院外心脏骤停非存活患者中,CLOVER3000 机械心肺复苏与人工心肺复苏的按压相关损伤总体发生率相似(92.5% vs 94.54%,校正比值比 0.62,95%CI 0.06-1.44)。

该单中心回顾性队列研究纳入 2019 年 4 月至 2022 年 8 月日本一家三级医疗中心收治的成人非创伤性院外心脏骤停非存活患者,均接受急诊医疗服务转运并完成尸检计算机断层扫描,比较 CLOVER3000 机械心肺复苏与人工心肺复苏的按压相关损伤。共纳入 189 例,CLOVER3000 组占 42.3%,人工心肺复苏组占 57.7%。按压相关损伤总体发生率两组相似(92.5% vs 94.54%;校正比值比 0.62,95%CI 0.06-1.44)。最常见损伤为前外侧肋骨骨折(88.7% vs 88.9%;校正比值比 1.03,95%CI 0.38-2.78),其次为胸骨骨折(53.1% vs 56.7%;校正比值比 0.68,95%CI 0.36-1.30)。作者结论为在小样本量下观察到两组按压相关损伤总体发生率相似。

要点

  • 在成人非创伤性院外心脏骤停非存活患者中,CLOVER3000 机械心肺复苏与人工心肺复苏的按压相关损伤总体发生率相似(92.5% vs 94.54%;校正比值比 0.62,95%CI 0.06-1.44)。
  • 前外侧肋骨骨折为两组最常见的按压相关损伤,发生率相似(88.7% vs 88.9%;校正比值比 1.03,95%CI 0.38-2.78)。
  • 胸骨骨折为两组第二常见的按压相关损伤(53.1% vs 56.7%;校正比值比 0.68,95%CI 0.36-1.30)。
  • 其他损伤的发生率在两组间无统计学差异。
  • 作者结论为在小样本量下观察到 CLOVER3000 与人工心肺复苏的按压相关损伤总体发生率相似。

适用人群与场景

  • 成人非创伤性院外心脏骤停非存活患者,由急诊医疗服务转运并接受尸检计算机断层扫描。
  • 研究时间范围为 2019 年 4 月至 2022 年 8 月,单中心,日本一家三级医疗中心。

研究设计与关键结果

  • 研究类型:单中心、回顾性队列研究,共纳入 189 例成人非创伤性院外心脏骤停非存活患者,CLOVER3000 组占 42.3%,人工心肺复苏组占 57.7%。
  • 按压相关损伤总体发生率:CLOVER3000 组 92.5% vs 人工心肺复苏组 94.54%,校正比值比 0.62(95%CI 0.06-1.44)。
  • 前外侧肋骨骨折:CLOVER3000 组 88.7% vs 人工心肺复苏组 88.9%,校正比值比 1.03(95%CI 0.38-2.78)。
  • 胸骨骨折:CLOVER3000 组 53.1% vs 人工心肺复苏组 56.7%,校正比值比 0.68(95%CI 0.36-1.30)。
  • 其他损伤的发生率在两组间无统计学差异。
  • 校正因素包括年龄、性别、旁观者心肺复苏实施情况和心肺复苏持续时间。

证据类型、等级与局限

  • 证据类型:单中心、回顾性队列研究。
  • 作者结论:在小样本量下观察到 CLOVER3000 与人工心肺复苏的按压相关损伤总体发生率相似。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 原文未据此给出推荐。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

AIM: The incidence of compression-associated injuries from using the CLOVER3000, a new mechanical cardiopulmonary resuscitation (CPR) device, is not well studied in the context of out-of-hospital cardiac arrest (OHCA). Thus, we aimed to compare compression-associated injuries between CLOVER3000 and manual CPR.

METHODS: This single-center, retrospective, cohort study used data from the medical records of a tertiary care center in Japan between April 2019 and August 2022. We included adult non-survivor patients with non-traumatic OHCA who were transported by emergency medical services and underwent post-mortem computed tomography. Compression-associated injuries were tested using logistic regression models adjusting for age, sex, bystander CPR performance, and CPR duration.

RESULTS: A total of 189 patients (CLOVER3000, 42.3%; manual CPR, 57.7%) were included in the analysis. The overall incidence of compression-associated injuries was similar between the two groups (92.5% vs. 94.54%; adjusted odds ratio (AOR), 0.62 [95% confidence interval (CI), 0.06-1.44]). The most common injury was anterolateral rib fractures with a similar incidence between the two groups (88.7% vs. 88.9%; AOR, 1.03 [95% CI, 0.38 to 2.78]). The second most common injury was sternal fracture in both groups (53.1% vs. 56.7%; AOR, 0.68 [95% CI, 0.36-1.30]). The incidence rates of other injuries were not statistically different between the both groups.

CONCLUSION: We observed a similar overall incidence of compression-associated injuries between the CLOVER3000 and manual CPR groups on small sample size.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Hayashi M, Tanizaki S, Nishida N, et al. Compression-associated injuries using CLOVER3000 device in non-survivor patients of OHCA: A retrospective cohort study. Am J Emerg Med. 2023. PMID: 36996591. doi:10.1016/j.ajem.2023.03.032

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。