文献速递重症综合管理与镇静镇痛消化、代谢与肾脏急症

单核细胞分布宽度、降钙素原与C反应蛋白对脓毒症诊断准确性的比较:系统评价与Meta分析

Comparison of the Diagnostic Accuracies of Monocyte Distribution Width, Procalcitonin, and C-Reactive Protein for Sepsis: A Systematic Review and Meta-Analysis.
PubMed 文献 · Crit Care Med · 2023-03-06
一句话结论Meta分析显示,单核细胞分布宽度诊断脓毒症的准确性(SROC曲线下面积0.85)与降钙素原、C反应蛋白相似。

该研究系统检索PubMed、Embase和Cochrane Library截至2022年10月1日的文献,纳入18项以Sepsis-2或Sepsis-3标准诊断脓毒症、报告单核细胞分布宽度(MDW)诊断准确性的研究。MDW汇总敏感度为84%(95%CI 79-88%),特异度为68%(95%CI 60-75%),诊断比值比为11.11(95%CI 7.36-16.77),SROC曲线下面积为0.85(95%CI 0.81-0.89),研究间存在显著异质性。8项研究比较MDW与降钙素原,SROC曲线下面积分别为0.88(95%CI 0.84-0.93)和0.82(95%CI 0.76-0.88);5项研究比较MDW与C反应蛋白,SROC曲线下面积分别为0.88(95%CI 0.83-0.93)和0.86(95%CI 0.78-0.95),均相似。作者建议进一步研究MDW与其他生物标志物联合应用以提高脓毒症检测准确性。

要点

  • MDW诊断脓毒症的汇总敏感度为84%(95%CI 79-88%),特异度为68%(95%CI 60-75%)。
  • MDW的SROC曲线下面积为0.85(95%CI 0.81-0.89),诊断比值比为11.11(95%CI 7.36-16.77)。
  • 8项研究比较MDW与降钙素原,SROC曲线下面积分别为0.88(95%CI 0.84-0.93)和0.82(95%CI 0.76-0.88),相似。
  • 5项研究比较MDW与C反应蛋白,SROC曲线下面积分别为0.88(95%CI 0.83-0.93)和0.86(95%CI 0.78-0.95),相似。
  • 研究间存在显著异质性;作者建议进一步研究MDW与其他生物标志物联合应用以提高脓毒症检测准确性。

适用人群与场景

  • 成人脓毒症患者,研究采用Sepsis-2或Sepsis-3标准诊断脓毒症。

诊断标准与关键阈值

  • 脓毒症诊断标准:Sepsis-2或Sepsis-3标准。

研究设计与关键结果

  • 系统评价与Meta分析,纳入18项诊断准确性研究,评估MDW对成人脓毒症的诊断准确性并与降钙素原和C反应蛋白比较。
  • MDW汇总敏感度84%(95%CI 79-88%),特异度68%(95%CI 60-75%),诊断比值比11.11(95%CI 7.36-16.77),SROC曲线下面积0.85(95%CI 0.81-0.89)。
  • 纳入研究间存在显著异质性。
  • 8项研究比较MDW与降钙素原,SROC曲线下面积分别为0.88(95%CI 0.84-0.93)和0.82(95%CI 0.76-0.88),相似。
  • 5项研究比较MDW与C反应蛋白,SROC曲线下面积分别为0.88(95%CI 0.83-0.93)和0.86(95%CI 0.78-0.95),相似。

证据类型、等级与局限

  • 证据类型:系统评价与Meta分析。
  • 纳入研究间存在显著异质性。
  • 局限:原文未报告其他局限性。

对床旁实践的改变

  • 作者认为,MDW是诊断脓毒症的可靠生物标志物,其诊断准确性与他汀类降钙素原和C反应蛋白相当。
  • 作者建议进一步研究MDW与其他生物标志物联合应用,以提高脓毒症检测的准确性。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: We performed a systemic review and meta-analysis to evaluate the diagnostic accuracy of monocyte distribution width (MDW) and to compare with procalcitonin and C-reactive protein (CRP), in adult patients with sepsis.

DATA SOURCES: A systematic literature search was performed in PubMed, Embase, and the Cochrane Library to identify all relevant diagnostic accuracy studies published before October 1, 2022.

STUDY SELECTION: Original articles reporting the diagnostic accuracy of MDW for sepsis detection with the Sepsis-2 or Sepsis-3 criteria were included.

DATA EXTRACTION: Study data were abstracted by two independent reviewers using a standardized data extraction form.

DATA SYNTHESIS: Eighteen studies were included in the meta-analysis. The pooled sensitivity and specificity of MDW were 84% (95% CI [79-88%]) and 68% (95% CI [60-75%]). The estimated diagnostic odds ratio and the area under the summary receiver operating characteristic curve (SROC) were 11.11 (95% CI [7.36-16.77]) and 0.85 (95% CI [0.81-0.89]). Significant heterogeneity was observed among the included studies. Eight studies compared the diagnostic accuracies of MDW and procalcitonin, and five studies compared the diagnostic accuracies of MDW and CRP. For MDW versus procalcitonin, the area under the SROC was similar (0.88, CI = 0.84-0.93 vs 0.82, CI = 0.76-0.88). For MDW versus CRP, the area under the SROC was similar (0.88, CI = 0.83-0.93 vs 0.86, CI = 0.78-0.95).

CONCLUSIONS: The results of the meta-analysis indicate that MDW is a reliable diagnostic biomarker for sepsis as procalcitonin and CRP. Further studies investigating the combination of MDW and other biomarkers are advisable to increase the accuracy in sepsis detection.

来源:Crit Care Med,查看原文。版权归原作者所有。

参考来源

  1. Huang YH, Chen CJ, Shao SC, et al. Comparison of the Diagnostic Accuracies of Monocyte Distribution Width, Procalcitonin, and C-Reactive Protein for Sepsis: A Systematic Review and Meta-Analysis. Crit Care Med. 2023. PMID: 36877030. doi:10.1097/CCM.0000000000005820

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。