文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

多方位质量改进项目对院前急救转运环境中急救员插管成功率的影响:一项前后对照研究

The effect of a multi-faceted quality improvement program on paramedic intubation success in the critical care transport environment: a before-and-after study.
PubMed 文献 · Scand J Trauma Resusc Emerg Med · 2023-02-22
一句话结论多方位质量改进项目使急救员首次插管成功率从60%升至86%(p<0.001),DASH-1A率从45%升至55%(p=0.1,未达预设统计学显著)。

该研究为回顾性数据库分析,比较质量改进项目实施前后急救员气管插管首次成功率(FPS)和首次尝试无缺氧低血压成功率(DASH-1A)的变化。纳入2016年1月至2021年12月以气管插管为首选策略的484例患者。总体FPS为72%(350/484),从干预前60%(86/144)升至干预后86%(148/173),p<0.001;DASH-1A从45%(55/122)升至55%(84/153),差异未达预设统计学显著(p=0.1)。作者认为实施多方位高级气道管理质量改进项目可提高急救员插管安全性。

要点

  • 纳入484例以气管插管为首选高级气道策略的患者,总体首次插管成功率(FPS)为72%(350/484)。
  • 质量改进项目实施后FPS从60%(86/144)升至86%(148/173),p<0.001。
  • DASH-1A成功率从45%(55/122)升至55%(84/153),差异未达预设统计学显著(p=0.1)。
  • 单因素分析显示,与FPS改善相关的因素为使用视频喉镜(VL)、神经肌肉阻滞和于医疗机构内插管。
  • 作者认为需结合现代设备、针对性培训、标准化和持续临床治理来维持急救员院前及转运环境中的安全插管。

适用人群与场景

  • 2016年1月至2021年12月期间,在大型区域重症转运机构中接受高级气道管理且以气管插管(ETI)为首选策略的全部患者,共484例。

研究设计与关键结果

  • 研究类型为回顾性数据库分析,比较质量改进项目实施前后FPS和DASH-1A率,纳入484例以ETI为首选策略的患者。
  • 总体首次插管成功率(FPS)为72%(350/484)。
  • FPS从干预前60%(86/144)升至干预后86%(148/173),p<0.001。
  • DASH-1A成功率从干预前45%(55/122)升至干预后55%(84/153),差异未达预设统计学显著(p=0.1)。
  • 单因素分析显示,与FPS改善相关的因素为使用视频喉镜(VL)、神经肌肉阻滞和于医疗机构内插管。

证据类型、等级与局限

  • 证据类型:回顾性数据库分析(前后对照研究)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,多方位高级气道管理质量改进项目可提高急救员首次插管成功率,并对DASH-1A率有非显著改善。
  • 作者认为,需结合现代设备、针对性培训、标准化和持续临床治理,以实现并维持急救员在院前和转运环境中的安全插管。
  • 单因素分析提示,使用视频喉镜、神经肌肉阻滞和于医疗机构内插管与FPS改善相关。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

INTRODUCTION: Endotracheal intubation (ETI) is an infrequent but key component of prehospital and retrieval medicine. Common measures of quality of ETI are the first pass success rates (FPS) and ETI on the first attempt without occurrence of hypoxia or hypotension (DASH-1A). We present the results of a multi-faceted quality improvement program (QIP) on paramedic FPS and DASH-1A rates in a large regional critical care transport organization.

METHODS: We conducted a retrospective database analysis, comparing FPS and DASH-1A rates before and after implementation of the QIP. We included all patients undergoing advanced airway management with a first strategy of ETI during the time period from January 2016 to December 2021.

RESULTS: 484 patients met the inclusion criteria during the study period. Overall, the first pass intubation success (FPS) rate was 72% (350/484). There was an increase in FPS from the pre-intervention period (60%, 86/144) to the post-intervention period (86%, 148/173), p < 0.001. DASH-1A success rates improved from 45% (55/122) during the pre-intervention period to 55% (84/153) but this difference did not meet pre-defined statistical significance (p = 0.1). On univariate analysis, factors associated with improved FPS rates were the use of video-laryngoscope (VL), neuromuscular blockage, and intubation inside a healthcare facility.

CONCLUSIONS: A multi-faceted advanced airway management QIP resulted in increased FPS intubation rates and a non-significant improvement in DASH-1A rates. A combination of modern equipment, targeted training, standardization and ongoing clinical governance is required to achieve and maintain safe intubation by paramedics in the prehospital and retrieval environment.

来源:Scand J Trauma Resusc Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. von Vopelius-Feldt J, Peddle M, Lockwood J, et al. The effect of a multi-faceted quality improvement program on paramedic intubation success in the critical care transport environment: a before-and-after study. Scand J Trauma Resusc Emerg Med. 2023. PMID: 36814266. doi:10.1186/s13049-023-01074-0

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。