脓毒性休克患者淋巴细胞短期炎症生物标志物谱与线粒体生物能量学缺陷相关:一项前瞻性队列研究
本研究为前瞻性队列研究,纳入64例脓毒性休克患者,于脓毒性休克管理第1天和第3天测量淋巴细胞常规呼吸、复合体I呼吸、复合体II呼吸、生化耦联效率及IL-1β、IL-6、IL-10、总淋巴细胞计数和C反应蛋白水平,并以第3天减第1天的差值评估变化。结果:复合体II呼吸与IL-1β呈负相关(Spearman ρ=-0.275,P=0.028);第1天生化耦联效率与IL-6呈负相关(Spearman ρ=-0.247,P=0.05);复合体II呼吸差值(第3天减第1天)与IL-6差值呈负相关(Spearman ρ=-0.261,P=0.042);复合体I呼吸差值与IL-6差值呈负相关(Spearman ρ=-0.346,P=0.006);常规呼吸差值分别与IL-10差值(Spearman ρ=-0.257,P=0.046)和IL-6差值(Spearman ρ=-0.32,P=0.012)呈负相关。结论认为淋巴细胞复合体I和复合体II的代谢改变与IL-6水平下降相关,可能提示整体炎症活动减弱。
要点
- 64例脓毒性休克患者中,淋巴细胞复合体II呼吸与IL-1β呈负相关(Spearman ρ=-0.275,P=0.028)。
- 第1天生化耦联效率与IL-6呈负相关(Spearman ρ=-0.247,P=0.05)。
- 复合体II呼吸差值(第3天减第1天)与IL-6差值呈负相关(Spearman ρ=-0.261,P=0.042)。
- 复合体I呼吸差值与IL-6差值呈负相关(Spearman ρ=-0.346,P=0.006)。
- 常规呼吸差值分别与IL-10差值(Spearman ρ=-0.257,P=0.046)和IL-6差值(Spearman ρ=-0.32,P=0.012)呈负相关。
适用人群与场景
- 纳入脓毒性休克患者,共64例;研究场景为脓毒性休克管理期间。
研究设计与关键结果
- 研究类型为前瞻性队列研究,纳入64例脓毒性休克患者,于脓毒性休克管理第1天和第3天测量淋巴细胞常规呼吸、复合体I呼吸、复合体II呼吸、生化耦联效率及IL-1β、IL-6、IL-10、总淋巴细胞计数、C反应蛋白,并用差值(第3天减第1天)评估变化。
- 复合体II呼吸与IL-1β呈负相关(Spearman ρ=-0.275,P=0.028)。
- 第1天生化耦联效率与IL-6呈负相关(Spearman ρ=-0.247,P=0.05)。
- 复合体II呼吸差值与IL-6差值呈负相关(Spearman ρ=-0.261,P=0.042)。
- 复合体I呼吸差值与IL-6差值呈负相关(Spearman ρ=-0.346,P=0.006)。
- 常规呼吸差值与IL-10差值呈负相关(Spearman ρ=-0.257,P=0.046),与IL-6差值呈负相关(Spearman ρ=-0.32,P=0.012)。
证据类型、等级与局限
- 证据类型:前瞻性队列研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,淋巴细胞复合体I和复合体II的代谢改变与IL-6水平下降相关,可能提示整体炎症活动减弱。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
Introduction: A biomarker strategy based on the quantification of an immune profile could provide a clinical understanding of the inflammatory state in patients with sepsis and its potential implications for the bioenergetic state of lymphocytes, whose metabolism is associated with altered outcomes in sepsis. The objective of this study is to investigate the association between mitochondrial respiratory states and inflammatory biomarkers in patients with septic shock. Methods: This prospective cohort study included patients with septic shock. Routine, complex I, complex II respiration, and biochemical coupling efficiency were measured to evaluate mitochondrial activity. We measured IL-1ß, IL-6, IL-10, total lymphocyte count, and C-reactive protein levels on days 1 and 3 of septic shock management as well as mitochondrial variables. The variability of these measurements was evaluated using delta counts (days 3-1 counts). Results: Sixty-four patients were included in this analysis. There was a negative correlation between complex II respiration and IL-1ß (Spearman ρ, -0.275; P = 0.028). Biochemical coupling efficiency at day 1 was negative correlated with IL-6: Spearman ρ, -0.247; P = 0.05. Delta complex II respiration was negatively correlated with delta IL-6 (Spearman ρ, -0.261; P = 0.042). Delta complex I respiration was negatively correlated with delta IL-6 (Spearman ρ, -0.346; P = 0.006), and delta routine respiration was also negatively correlated with both delta IL-10 (Spearman ρ, -0.257; P = 0.046) and delta IL-6 (Spearman ρ, -0.32; P = 0.012). Conclusions: The metabolic change observed in mitochondrial complex I and complex II of lymphocytes is associated with a decrease in IL-6 levels, which can signal a decrease in global inflammatory activity.
参考来源
- Nedel WL, Strogulski NR, Rodolphi MS, et al. SHORT-TERM INFLAMMATORY BIOMARKER PROFILES ARE ASSOCIATED WITH DEFICIENT MITOCHONDRIAL BIOENERGETICS IN LYMPHOCYTES OF SEPTIC SHOCK PATIENTS-A PROSPECTIVE COHORT STUDY. Shock. 2022. PMID: 36795959. doi:10.1097/SHK.0000000000002055
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。