消防员院外心脏骤停中持续胸外按压速率与深度的时程分析
该研究分析消防员在院外心脏骤停中使用心肺复苏反馈装置和自动体外除颤器时的胸外按压质量,纳入134例患者,每5秒计算2分钟按压周期内的平均深度和速率,并用回归模型评估按压深度、速率与时间的函数关系。结果:平均深度48(9)mm,2分钟内深度减少3.39 mm(p<0.001);平均速率112.06(5.87)次/分,速率与按压时间无显著关系(p=0.077)。仅33.58%的患者平均深度在指南范围(50–60 mm)内,92.54%的病例速率达标。提示持续胸外按压中深度随时间下降,近三分之二患者平均深度未达指南范围。
要点
- 消防员持续胸外按压2分钟内深度平均减少3.39 mm(p<0.001),提示按压深度随时间下降。
- 平均按压速率112.06(5.87)次/分,速率与按压时间无显著关系(p=0.077),不受持续时间影响。
- 仅33.58%的患者平均按压深度在指南范围(50–60 mm)内,近三分之二未达标。
- 92.54%的病例按压速率达到指南要求,速率达标率远高于深度达标率。
- 整体平均按压深度为48(9)mm,低于指南下限50 mm。
适用人群与场景
- 院外心脏骤停事件中由配备心肺复苏反馈装置和自动体外除颤器的第一响应者(消防员)实施持续胸外按压的患者,共分析134例。
诊断标准与关键阈值
- 按压深度指南范围为50至60 mm。
- 按压速率指南要求未在原文列出具体数值。
研究设计与关键结果
- 研究类型为对第一响应组(消防员)院外心脏骤停数据的分析,纳入134例患者,每5秒计算2分钟心肺复苏周期内的平均按压深度和速率,并建立回归模型评估按压深度和速率与时间的函数关系。
- 平均(标准差)按压深度为48(9)mm;按压深度与心肺复苏持续时间呈反向关系,2分钟心肺复苏内按压深度减少3.39 mm(p<0.001)。
- 平均(标准差)按压速率为112.06(5.87)次/分;按压速率与心肺复苏持续时间无显著关系(p=0.077)。
- 平均按压深度在指南范围(50至60 mm)内的患者事件占33.58%,按压速率达到指南要求的病例占92.54%。
证据类型、等级与局限
- 证据类型:对第一响应组院外心脏骤停事件的分析(观察性分析)。
- 局限:原文未报告局限性。
对床旁实践的改变
- 原文结论:2分钟持续胸外按压期间观察到按压深度下降,而按压速率未受影响;三分之一患者接受的平均按压深度在指南范围(50至60 mm)内。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Quality of chest compressions (CC) during cardiopulmonary resuscitation (CPR) often do not meet guideline recommendations for rate and depth. This may be due to the fatiguing nature of physically compressing a patient's chest, meaning that CPR quality reduces over time.
OBJECTIVE: This analysis investigates the effect of CPR duration on the performance of continuous CCs delivered by firefighters equipped with CPR feedback devices.
METHODS: Data were collected from a first responder group which used CPR feedback and automatic external defibrillator devices when attending out-of-hospital cardiac arrest events. Depth and rate of CC were analysed for 134 patients. Mean CC depth and rate were calculated every 5 s during two-minute episodes of CPR. Regression models were created to evaluate the relationship between applied CC depth and rate as a function of time.
RESULTS: Mean (SD) CC depth during the investigation was 48 (9) mm. An inverse relationship was observed between CC depth and CPR duration, where CC depth decreased by 3.39 mm, over two-minutes of CPR (p < 0.001). Mean (SD) CC rate was 112.06 (5.87) compressions per minute. No significant relationship was observed between CC rate and CPR duration (p = 0.077). Mean depth was within guideline range for 33.58% of patient events, while guideline rate was observed in 92.54% of cases.
CONCLUSIONS: A reduction in CC depth was observed during two-minutes of continuous CCs while CC rate was not affected. One third of patients received a mean CC depth within guideline range (50 to 60 mm).
参考来源
- McAlister O, Harvey A, Currie H, et al. Temporal analysis of continuous chest compression rate and depth performed by firefighters during out of hospital cardiac arrest. Resuscitation. 2023. PMID: 36806652. doi:10.1016/j.resuscitation.2023.109738
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。