线粒体DNA与外周血单个核细胞呼吸测定对烧伤相关脓毒症的诊断价值
本研究为单中心前瞻性观察研究的随访分析,纳入10名健康志愿者和24例烧伤患者,纵向随访,按经验性临床标准分为脓毒症组和非脓毒症组。结果显示,脓毒症烧伤患者线粒体DNA显著高于健康志愿者(P<0.0001)和非脓毒症患者(P<0.0001),AUC为0.685(95%CI 0.50-0.86)。外周血单个核细胞呼吸测定在烧伤患者中较健康志愿者升高,但脓毒症与非脓毒症患者间无差异;亚组分析显示脓毒症诊断后幸存者常规呼吸(P=0.003)和最大呼吸(P=0.011)高于非幸存者。作者认为线粒体DNA可能对烧伤脓毒症有诊断价值,外周血单个核细胞呼吸测定可能对死亡预后有价值,需更大规模多中心研究进一步验证。
要点
- 脓毒症烧伤患者线粒体DNA显著高于健康志愿者(P<0.0001)和非脓毒症患者(P<0.0001),健康志愿者与非脓毒症烧伤患者间无显著差异(P=0.187)。
- 线粒体DNA诊断烧伤脓毒症的ROC曲线下面积为0.685(95%CI 0.50-0.86)。
- 外周血单个核细胞呼吸测定在烧伤患者中较健康志愿者升高,但脓毒症与非脓毒症患者间无差异。
- 亚组分析显示,脓毒症诊断后幸存者常规呼吸(P=0.003)和最大呼吸(P=0.011)高于非幸存者。
- SOFA标准比较脓毒症与之前/非脓毒症患者,脓毒症组心率显著更高(P=0.012),平均动脉压显著更低(P=0.039)。
适用人群与场景
- 烧伤患者(n=24)和健康志愿者(n=10),患者无论是否发生脓毒症均纳入并纵向随访。
诊断标准与关键阈值
- 根据经验性临床标准将患者样本分类为脓毒症或非脓毒症。
- 同时比较序贯器官衰竭评估(SOFA)标准。
研究设计与关键结果
- 研究类型为单中心前瞻性观察研究的随访分析,样本量为10名健康志愿者和24例烧伤患者。
- 脓毒症烧伤患者线粒体DNA显著高于健康志愿者(P<0.0001)和非脓毒症患者(P<0.0001),健康志愿者与非脓毒症烧伤患者间无显著差异(P=0.187)。
- 线粒体DNA的ROC曲线下面积为0.685(95%CI 0.50-0.86)。
- 外周血单个核细胞呼吸测定:烧伤患者常规呼吸和最大呼吸潜力较健康志愿者增加,但非脓毒症与脓毒症患者样本间无差异。
- 亚组分析显示脓毒症诊断后幸存者常规呼吸(P=0.003)和最大呼吸(P=0.011)高于非幸存者。
- SOFA标准比较脓毒症与之前/非脓毒症患者,脓毒症组心率显著更高(P=0.012),平均动脉压显著更低(P=0.039)。
证据类型、等级与局限
- 证据类型:单中心前瞻性观察研究的随访分析。
- 局限:原文报告需更大规模多中心研究进一步验证线粒体DNA和外周血单个核细胞呼吸测定作为烧伤脓毒症诊断和预后生物标志物的价值。
对床旁实践的改变
- 作者认为线粒体DNA可能对烧伤脓毒症有诊断价值,外周血单个核细胞呼吸测定在烧伤中非特异性升高,但可能对死亡预后有价值。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
Background: Sepsis is the leading cause of mortality among burn patients that survive acute resuscitation. Clinical criteria have poor diagnostic value for burn-induced sepsis, making it difficult to diagnose. Protein biomarkers (e.g., procalcitonin) have been examined with limited success. We aimed to explore other biomarkers related to mitochondria (mitochondrial DNA [mtDNA]) and mitochondrial function of peripheral blood mononuclear cells (PBMCs) for sepsis diagnosis in burn patients. Methods: We conducted a follow-up analysis of a single center, prospective observational study of subjects (n = 10 healthy volunteers, n = 24 burn patients) to examine the diagnostic value of mtDNA and PBMC respirometry. Patients were enrolled regardless of sepsis status and followed longitudinally. Patient samples were classified as septic or not based on empiric clinical criteria. Isolated PBMCs were loaded into a high-resolution respirometer, and circulating mtDNA was measured with a PCR-based assay. Sequential Organ Failure Assessment (SOFA) criteria were also compared. Results: The SOFA criteria comparing septic versus before/nonseptic patients revealed significantly higher heart rate ( P = 0.012) and lower mean arterial pressure ( P = 0.039) in burn sepsis. MtDNA was significantly elevated in septic burn patients compared with healthy volunteers ( P < 0.0001) and nonseptic patients ( P < 0.0001), with no significant difference between healthy volunteers and nonseptic burn patients ( P = 0.187). The area under the ROC curve (AUC) for mtDNA was 0.685 (95% confidence interval = 0.50-0.86). For PBMC respirometry, burn patients exhibited increased routine and maximal respiration potential compared with healthy volunteers. However, no difference was found between nonseptic and septic patient samples. A subanalysis revealed a significant mortality difference in PBMC respirometry after sepsis diagnosis, wherein survivors had higher routine respiration ( P = 0.003) and maximal respiration ( P = 0.011) compared with nonsurvivors. Conclusion: Our findings reveal that mtDNA may have diagnostic value for burn sepsis, whereas PBMC respirometry is nonspecifically elevated in burns, but may have value in mortality prognosis. A larger, multisite study is warranted for further validity of the diagnostic value of mtDNA and PBMC respirometry as biomarkers for prognosis of sepsis and outcomes in burn patients.
参考来源
- Robles MC, Heard TC, Chao T, et al. DIAGNOSTIC VALUE OF MITOCHONDRIAL DNA AND PERIPHERAL BLOOD MONONUCLEAR CELL RESPIROMETRY FOR BURN-RELATED SEPSIS. Shock. 2022. PMID: 36730861. doi:10.1097/SHK.0000000000002025
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。