重症患者动脉导管与外周静脉穿刺血培养的污染情况:一项前瞻性多中心诊断研究
在这项于五家医院开展的前瞻性多中心诊断研究中,共纳入590对来自重症成人的配对血培养(动脉导管与静脉穿刺各一套)。动脉导管血培养阳性33/590(6.0%)、污染2/590(0.3%);静脉穿刺阳性36/590(6.1%)、污染4/590(0.7%)。污染比例差值(动脉导管-静脉穿刺)为-0.3%,单侧95%CI上限+0.3%,未超过预设的+2.0%界值,非劣效性成立(非劣效P<.001)。作者认为,在重症患者中从动脉导管采集血培养是静脉穿刺可接受的替代方法。
要点
- 在590对配对血培养中,动脉导管污染2/590(0.3%),静脉穿刺污染4/590(0.7%)。
- 污染比例差值(动脉导管-静脉穿刺)为-0.3%,单侧95%CI上限+0.3%,未超过预设+2.0%界值,非劣效性成立(P<.001)。
- 动脉导管血培养阳性33/590(6.0%),静脉穿刺阳性36/590(6.1%)。
- 590对中41对(6.9%)经感染科专家盲法评估为真实血流感染。
- 作者认为,重症患者从动脉导管采集血培养是静脉穿刺可接受的替代方法。
适用人群与场景
- 重症成人患者,有临床指征需采集血培养且疑似血流感染。
- 纳入的是配对血培养采集事件(动脉导管一套、静脉穿刺一套),共590对。
诊断标准与关键阈值
- 污染定义:假阳性结果数相对于总操作数的比例。
- 真实血流感染参考标准:由感染科专家盲法评估。
- 非劣效界值:动脉导管血培养污染比例不超过静脉穿刺2.0%。
研究设计与关键结果
- 研究设计:前瞻性多中心诊断研究,五家医院,2018年12月至2021年7月,共1,655次血培养事件中纳入590对配对血培养。
- 主要终点:动脉导管污染2/590(0.3%)vs 静脉穿刺污染4/590(0.7%),污染比例差值(动脉导管-静脉穿刺)-0.3%(单侧95%CI上限+0.3%),未超过+2.0%界值,非劣效性成立(P<.001)。
- 次要结果:动脉导管血培养阳性33/590(6.0%)vs 静脉穿刺36/590(6.1%);590对中41对(6.9%)为真实血流感染。
证据类型、等级与局限
- 证据类型:前瞻性多中心诊断研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,在重症患者中从动脉导管采集血培养是静脉穿刺可接受的替代方法。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Collecting blood cultures from indwelling arterial catheters is an attractive option in critically ill adult patients when peripheral venipuncture is difficult. However, whether the contamination proportion of blood cultures from arterial catheters is acceptable compared with that from venipuncture is inconclusive.
RESEARCH QUESTION: Is contamination of blood cultures from arterial catheters noninferior to that from venipuncture in critically ill adult patients with suspected bloodstream infection?
STUDY DESIGN AND METHODS: In this multicenter prospective diagnostic study conducted at five hospitals, we enrolled episodes of paired blood culture collection, each set consisting of blood drawn from an arterial catheter and another by venipuncture, were obtained from critically ill adult patients with cilinical indication. The primary measure was the proportion of contamination, defined as the number of false-positive results relative to the total number of procedures done. The reference standard for true bloodstream infection was blinded assessment by infectious disease specialists. We examined the noninferiority hypothesis that the contamination proportion of blood cultures from arterial catheters did not exceed that from venipuncture by 2.0%.
RESULTS: Of 1,655 episodes of blood culture from December 2018 to July 2021, 590 paired blood culture episodes were enrolled, and 41 of the 590 episodes (6.9%) produced a true bloodstream infection. In blood cultures from arterial catheters, 33 of 590 (6.0%) were positive, and two of 590 (0.3%) were contaminated; in venipuncture, 36 of 590 (6.1%) were positive, and four of 590 (0.7%) were contaminated. The estimated difference in contamination proportion (arterial catheter - venipuncture) was -0.3% (upper limit of one-sided 95% CI, +0.3%). The upper limit of the 95% CI did not exceed the predefined margin of +2.0%, establishing noninferiority (P for noninferiority < .001).
INTERPRETATION: Obtaining blood cultures from arterial catheters is an acceptable alternative to venipuncture in critically ill patients.
CLINICAL TRIAL REGISTRATION: University Hospital Medical Information Network Center (UMIN-CTR); No.: UMIN000035392; URL: https://center6.umin.ac.jp/.
参考来源
- Nakayama I, Izawa J, Gibo K, et al. Contamination of Blood Cultures From Arterial Catheters and Peripheral Venipuncture in Critically Ill Patients: A Prospective Multicenter Diagnostic Study. Chest. 2023. PMID: 36731787. doi:10.1016/j.chest.2023.01.030
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。