文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

重症监护环境中吸气呼吸肌超声的方法学与临床计量学评价:系统综述与荟萃分析

Methodological and Clinimetric Evaluation of Inspiratory Respiratory Muscle Ultrasound in the Critical Care Setting: A Systematic Review and Meta-Analysis.
PubMed 文献 · Crit Care Med · 2023-01-20
一句话结论在ICU成人中,膈肌超声(厚度、增厚分数、移动度)信度、效度和反应性良好,但图像采集与分析方法差异显著,尚无学会级共识。

该系统综述与荟萃分析系统检索5个数据库至2021年11月24日,纳入至少50例成人ICU患者、报告膈肌或肋间肌超声(回声纹理、肌肉厚度、增厚分数或移动度)并评价至少一项临床计量学特性的研究。共纳入60项研究、5025例患者,其中39项研究进入荟萃分析。最常测量的是使用线阵探头B模式的膈肌厚度(DT)或膈肌增厚分数(DTF),以及使用凸阵探头M模式的膈肌移动度(DE)。组间与组内测量信度总体优秀,DT的信度最高(ICC 0.98,95%CI 0.94-0.99);汇总数据显示DT、DTF和DE对拔管后48至72小时预测撤机结局具有可接受至优秀的准确性(DTF AUC 0.79,95%CI 0.73-0.85),DT成像对随时间变化有反应性;肋间肌仅3项符合条件的研究,肋间肌增厚分数对拔管后48小时预测撤机结局具有优秀准确性(AUC 0.84,95%CI 0.78-0.91)。结论认为膈肌超声在ICU患者中可靠、有效且具有反应性,但图像采集和分析方法存在显著差异,未来应致力于制定标准化超声成像方案并进一步研究肋间肌成像的作用。

要点

  • 共纳入60项研究、5025例成人ICU患者,39项研究进入荟萃分析,评估膈肌与肋间肌超声的临床计量学特性。
  • 最常测量的指标为线阵探头B模式下的膈肌厚度(DT)或膈肌增厚分数(DTF),以及凸阵探头M模式下的膈肌移动度(DE)。
  • 组间与组内测量信度总体优秀,DT的信度最高(ICC 0.98,95%CI 0.94-0.99)。
  • 汇总数据显示DT、DTF和DE对拔管后48至72小时预测撤机结局具有可接受至优秀的准确性(DTF AUC 0.79,95%CI 0.73-0.85),DT成像对随时间变化有反应性。
  • 肋间肌仅3项符合条件的研究,肋间肌增厚分数对拔管后48小时预测撤机结局具有优秀准确性(AUC 0.84,95%CI 0.78-0.91)。

适用人群与场景

  • 纳入标准:至少纳入50例成人ICU患者,报告呼吸肌(膈肌或肋间肌)超声测量回声纹理、肌肉厚度、增厚分数或移动度,并评价至少一项临床计量学特性的研究。

研究设计与关键结果

  • 研究类型:系统综述与荟萃分析,系统检索5个数据库至2021年11月24日,由两名独立评价者评估标题、摘要和全文是否符合纳入标准。
  • 共纳入60项研究、5025例患者,其中39项研究进入荟萃分析。
  • 最常测量的指标为使用线阵探头B模式的膈肌厚度(DT)或膈肌增厚分数(DTF),或使用凸阵探头M模式的膈肌移动度(DE);所有研究中成像方法和采集存在显著差异。
  • 组间与组内测量信度总体优秀,DT的信度最高(ICC 0.98,95%CI 0.94-0.99)。
  • 汇总数据显示DT、DTF和DE对拔管后48至72小时预测撤机结局具有可接受至优秀的准确性(DTF AUC 0.79,95%CI 0.73-0.85)。
  • DT成像对随时间变化有反应性。
  • 肋间肌仅3项符合条件的研究;肋间肌增厚分数对拔管后48小时预测撤机结局具有优秀准确性(AUC 0.84,95%CI 0.78-0.91)。

证据类型、等级与局限

  • 证据类型:系统综述与荟萃分析。
  • 纳入60项研究、5025例患者,39项研究进入荟萃分析;仅3项符合条件的研究涉及肋间肌。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为膈肌超声在ICU患者中可靠、有效且具有反应性,但图像采集和分析方法存在显著差异。
  • 作者认为未来工作应致力于制定标准化超声成像方案,并考虑进一步研究肋间肌成像的作用。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: Significant variations exist in the use of respiratory muscle ultrasound in intensive care with no society-level consensus on the optimal methodology. This systematic review aims to evaluate, synthesize, and compare the clinimetric properties of different image acquisition and analysis methodologies.

DATA SOURCES: Systematic search of five databases up to November 24, 2021.

STUDY SELECTION: Studies were included if they enrolled at least 50 adult ICU patients, reported respiratory muscle (diaphragm or intercostal) ultrasound measuring either echotexture, muscle thickness, thickening fraction, or excursion, and evaluated at least one clinimetric property. Two independent reviewers assessed titles, abstracts, and full text against eligibility.

DATA EXTRACTION: Study demographics, ultrasound methodologies, and clinimetric data.

DATA SYNTHESIS: Sixty studies, including 5,025 patients, were included with 39 studies contributing to meta-analyses. Most commonly measured was diaphragm thickness (DT) or diaphragm thickening fraction (DTF) using a linear transducer in B-mode, or diaphragm excursion (DE) using a curvilinear transducer in M-mode. There are significant variations in imaging methodology and acquisition across all studies. Inter- and intrarater measurement reliabilities were generally excellent, with the highest reliability reported for DT (ICC, 0.98; 95% CI, 0.94-0.99). Pooled data demonstrated acceptable to excellent accuracy for DT, DTF, and DE to predicting weaning outcome after 48 to 72 hours postextubation (DTF AUC, 0.79; 95% CI, 0.73-0.85). DT imaging was responsive to change over time. Only three eligible studies were available for intercostal muscles. Intercostal thickening fraction was shown to have excellent accuracy of predicting weaning outcome after 48-hour postextubation (AUC, 0.84; 95% CI, 0.78-0.91).

CONCLUSIONS: Diaphragm muscle ultrasound is reliable, valid, and responsive in ICU patients, but significant variation exists in the imaging acquisition and analysis methodologies. Future work should focus on developing standardized protocols for ultrasound imaging and consider further research into the role of intercostal muscle imaging.

来源:Crit Care Med,查看原文。版权归原作者所有。