文献速递呼吸衰竭与机械通气儿科与产科急症重症综合管理与镇静镇痛

儿童气管插管时应用无呼吸氧合减少严重低氧血症与插管相关不良事件的效果

Effect of apneic oxygenation with intubation to reduce severe desaturation and adverse tracheal intubation-associated events in critically ill children.
PubMed 文献 · Crit Care · 2023-01-17
一句话结论儿科ICU质量改进项目中,无呼吸氧合使用率从23%升至68%,校正中心聚集后与插管相关不良事件减少相关(aOR 0.75),但进一步校正患者与操作者特征后该关联未达统计学显著。

该质量改进项目在14个儿科ICU于2016-2020年实施无呼吸氧合(经鼻导管给氧)联合插管安全核查表等干预,共纳入6549次气管插管。无呼吸氧合使用率从23%升至68%(p<0.001)。校正中心聚集后,无呼吸氧合与插管相关不良事件发生率降低相关(10.5% vs 13.5%,aOR 0.75,95%CI 0.58-0.98,p=0.03);但进一步校正患者与操作者特征后,该关联未达统计学显著(aOR 0.90,95%CI 0.72-1.12,p=0.33),低氧血症发生率无差异(14.2% vs 15.2%,p=0.43)。作者认为该结果可能由患者、操作者及实践因素差异解释。

要点

  • 14个儿科ICU质量改进项目共6549次气管插管,无呼吸氧合使用率从23%升至68%,p<0.001。
  • 无呼吸氧合组插管相关不良事件10.5% vs 未使用组13.5%,p<0.001;校正中心聚集后aOR 0.75(95%CI 0.58-0.98,p=0.03)。
  • 进一步校正患者与操作者特征后,无呼吸氧合与插管相关不良事件无独立关联:aOR 0.90(95%CI 0.72-1.12,p=0.33)。
  • 低氧血症(SpO2<80%)发生率无差异:无呼吸氧合组14.2% vs 未使用组15.2%,p=0.43。
  • 无呼吸氧合在婴儿、原发心脏诊断、困难气道特征、因呼吸或神经衰竭或休克插管者中使用较少,在操作类插管及视频喉镜辅助插管中使用较多。

适用人群与场景

  • 需要气管插管的危重患儿,收治于14个儿科ICU,研究期间为2016-2020年。
  • 无呼吸氧合在插管婴儿、原发心脏诊断、困难气道特征、因呼吸或神经衰竭或休克插管者中使用较少;在操作类插管及视频喉镜辅助插管中使用较多。

处置流程与药物剂量

  • 无呼吸氧合经鼻导管给氧标准流量:婴儿(<1岁)5 L/min,年幼儿童(1-7岁)10 L/min,年长儿童(≥8岁)15 L/min。
  • 实施内容包括插管安全核查表、领导支持、本地 champion 及对一线临床医生的数据反馈。

研究设计与关键结果

  • 研究类型为质量改进项目,在14个儿科ICU实施,共纳入6549次气管插管;实施前阶段2554次(39.0%),实施后阶段3995次(61.0%)。
  • 无呼吸氧合使用率从23%升至68%,p<0.001。
  • 主要结局插管相关不良事件:无呼吸氧合组10.5% vs 未使用组13.5%,p<0.001;校正中心聚集后aOR 0.75(95%CI 0.58-0.98,p=0.03)。
  • 进一步校正患者与操作者特征后,无呼吸氧合与插管相关不良事件无独立关联:aOR 0.90(95%CI 0.72-1.12,p=0.33)。
  • 次要结局低氧血症(SpO2<80%):无呼吸氧合组14.2% vs 未使用组15.2%,p=0.43。

证据类型、等级与局限

  • 证据类型:多中心质量改进项目(14个儿科ICU),非随机干预。
  • 局限:原文报告该结果可能由患者、操作者及实践因素差异解释;试验未注册。

对床旁实践的改变

  • 作者认为,在儿科ICU需要气管插管的患儿中,校正中心层面聚集后无呼吸氧合与插管相关不良事件减少相关,但该结果可能由患者、操作者及实践因素差异解释。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Determine if apneic oxygenation (AO) delivered via nasal cannula during the apneic phase of tracheal intubation (TI), reduces adverse TI-associated events (TIAEs) in children.

METHODS: AO was implemented across 14 pediatric intensive care units as a quality improvement intervention during 2016-2020. Implementation consisted of an intubation safety checklist, leadership endorsement, local champion, and data feedback to frontline clinicians. Standardized oxygen flow via nasal cannula for AO was as follows: 5 L/min for infants (< 1 year), 10 L/min for young children (1-7 years), and 15 L/min for older children (≥ 8 years). Outcomes were the occurrence of adverse TIAEs (primary) and hypoxemia (SpO2 < 80%, secondary).

RESULTS: Of 6549 TIs during the study period, 2554 (39.0%) occurred during the pre-implementation phase and 3995 (61.0%) during post-implementation phase. AO utilization increased from 23 to 68%, p < 0.001. AO was utilized less often when intubating infants, those with a primary cardiac diagnosis or difficult airway features, and patient intubated due to respiratory or neurological failure or shock. Conversely, AO was used more often in TIs done for procedures and those assisted by video laryngoscopy. AO utilization was associated with a lower incidence of adverse TIAEs (AO 10.5% vs. without AO 13.5%, p < 0.001), aOR 0.75 (95% CI 0.58-0.98, p = 0.03) after adjusting for site clustering (primary analysis). However, after further adjusting for patient and provider characteristics (secondary analysis), AO utilization was not independently associated with the occurrence of adverse TIAEs: aOR 0.90, 95% CI 0.72-1.12, p = 0.33 and the occurrence of hypoxemia was not different: AO 14.2% versus without AO 15.2%, p = 0.43.

CONCLUSION: While AO use was associated with a lower occurrence of adverse TIAEs in children who required TI in the pediatric ICU after accounting for site-level clustering, this result may be explained by differences in patient, provider, and practice factors. Trial Registration Trial not registered.

来源:Crit Care,查看原文。版权归原作者所有。

参考来源

  1. Napolitano N, Polikoff L, Edwards L, et al. Effect of apneic oxygenation with intubation to reduce severe desaturation and adverse tracheal intubation-associated events in critically ill children. Crit Care. 2023. PMID: 36650568. doi:10.1186/s13054-023-04304-0

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。