文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

应用自动斑点追踪成像测量膈肌移动度并预测机械通气脱机结局

Using automatic speckle tracking imaging to measure diaphragm excursion and predict the outcome of mechanical ventilation weaning.
PubMed 文献 · Crit Care · 2023-01-14
一句话结论前瞻性多中心观察性研究显示,自动斑点追踪测得的膈肌移动度与速度与人工M型超声高度一致,对预测脱机失败、延长脱机及院内不良结局有诊断价值。

该前瞻性、多中心、观察性研究纳入160例重症患者,在自主呼吸试验前用斑点追踪超声测量右/左半膈肌移动度与速度,同时以M型超声人工测量作为对照,最终88例完成脱机结局随访,脱机失败发生率为43.18%。自动测量的平均移动度与速度同人工测量显著相关(R分别为0.69和0.65)。ROC分析显示,平均移动度与膈肌速度对延长脱机有较高诊断价值(AUROC分别为0.824和0.786),对脱机失败和院内死亡/退出治疗有中等诊断价值(AUROC分别为0.659和0.653)。作者认为自动斑点追踪分析可作为指导临床脱机策略的可靠工具。

要点

  • 研究纳入160例重症患者,88例完成脱机结局随访,脱机失败总体发生率为43.18%。
  • 自动斑点追踪测量的平均移动度与速度同人工M型超声测量显著相关,R分别为0.69和0.65。
  • 平均膈肌移动度预测延长脱机的AUROC为0.824,膈肌速度预测延长脱机的AUROC为0.786。
  • 膈肌移动度预测脱机失败的AUROC为0.659,预测院内死亡/退出治疗的AUROC为0.653。
  • 作者认为自动斑点追踪分析是指导临床脱机策略的可靠工具。

适用人群与场景

  • 重症医学科接受机械通气、拟行自主呼吸试验的危重症患者,在自主呼吸试验前接受斑点追踪超声检查。

研究设计与关键结果

  • 研究类型为前瞻性、多中心、观察性研究,共160例危重症患者接受右/左半膈肌斑点追踪超声检查,最终88例完成脱机结局随访。
  • 脱机失败总体发生率为43.18%,患者按结局分为脱机失败组与脱机成功组。
  • 自动斑点追踪测量的平均移动度与人工M型超声测量显著相关(R 0.69),自动测量的速度与人工测量也显著相关(R 0.65)。
  • ROC曲线分析显示,平均移动度预测延长脱机的AUROC为0.824,膈肌速度预测延长脱机的AUROC为0.786。
  • 膈肌移动度预测脱机失败的AUROC为0.659,预测院内死亡/退出治疗的AUROC为0.653。

证据类型、等级与局限

  • 证据类型:前瞻性、多中心、观察性研究(先导研究)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,自动斑点追踪分析膈肌与传统人工超声测量高度一致,膈肌移动度及其速度有助于预测机械通气脱机失败、延长脱机及院内不良结局,可作为指导临床脱机策略的可靠工具。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

INTRODUCTION: The speckle tracking ultrasound is an innovative technology enabling distinct assessment of diaphragmatic movement, yet the relative data are scarce. In this pilot study, we sought to evaluate the predictive value of the weaning outcome of automatic speckle tracking in assessing diaphragm excursion.

METHODS: This is a prospective, multicenter, observational study. A total of 160 critically ill subjects underwent speckle-tracking ultrasonography of the right/left hemidiaphragm before the spontaneous breathing trial. Meanwhile, the diaphragm excursion and velocity values were measured manually by M-mode ultrasound. Patients were divided into weaning-failure and weaning-success groups. The correlation was assessed between automatic and manual measurement, and the diagnostic efficacy of automatic measured excursion and velocity for predicting weaning outcome was analyzed.

RESULTS: A total of 88 patients completed the follow-up of the weaning outcome. The overall incidence of weaning failure was 43.18%. There was a significant correlation between the automatic measurement of mean excursion and velocity assessed by speckle tracking imaging and manual measurement (R 0.69 and 0.65, respectively). Receiver operating characteristic (ROC) curve analysis showed that the mean excursion and diaphragmatic velocity exhibited high diagnostic values for prolonged weaning [area under the ROC curve (AUROC) 0.824 and 0.786, respectively]. The diaphragmatic excursion showed moderate diagnostic value for predicting both weaning failure and in-hospital death/withdrawal of treatment (AUROC 0.659 and 0.653, respectively).

CONCLUSION: Automatic speckle tracking analysis of the diaphragm showed high consistency with conventional manual ultrasound measures. Diaphragmatic excursion and its excursion velocity helped predict mechanical ventilation weaning failure, prolonged weaning, as well as in-hospital adverse outcomes, which served as a reliable tool in guiding clinical weaning strategy.

KEY MESSAGE: Automatic speckle tracking analysis of the diaphragm showed high consistency with conventional manual ultrasound measures. Diaphragmatic excursion and its excursion velocity helped predict mechanical ventilation weaning failure, prolonged weaning, as well as in-hospital adverse outcomes.

SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13054-022-04288-3.

来源:Crit Care,查看原文。版权归原作者所有。

参考来源

  1. Huang D, Song F, Luo B, et al. Using automatic speckle tracking imaging to measure diaphragm excursion and predict the outcome of mechanical ventilation weaning. Crit Care. 2023. PMID: 36639710. doi:10.1186/s13054-022-04288-3

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。