新生儿出生时复苏的通气装置:系统评价与Meta分析
该系统评价与Meta分析纳入9项研究共3621名新生儿(5项RCT、2项含干预组合的RCT、2项前瞻性队列),比较定压装置(FPD,T型管或呼吸机)与手动驱动装置(HDPD,自动充气或气流充气复苏囊)在新生儿复苏中的临床结局。5项RCT的Meta分析显示FPD显著降低支气管肺发育不良(RR 0.68,95%CI 0.48-0.96,NNT 31)及产房插管、机械通气需求、机械通气时间、表面活性物质需求;总体分析显示FPD组死亡率更低(OR 0.57,95%CI 0.47-0.69,NNT 12.7),囊性PVL风险降低(OR 0.59,95%CI 0.41-0.85,NNT 27),气胸发生率相似(OR 0.82,95%CI 0.44-1.52)。作者结论认为FPD改善呼吸过渡并降低BPD,证据确定性极低至中等,提示死亡率与cPVL下降,仍需进一步研究确认。
要点
- 5项RCT的Meta分析:FPD较HDPD降低支气管肺发育不良(RR 0.68,95%CI 0.48-0.96,NNT 31)。
- 5项RCT:FPD降低产房插管(RR 0.72,95%CI 0.58-0.88,NNT 13.4)、机械通气需求(RR 0.81,95%CI 0.67-0.96,NNT 17)及机械通气时间(MD -1.54天,95%CI -3.03至-0.05)。
- 5项RCT:FPD降低表面活性物质需求(RR 0.79,95%CI 0.64-0.96,NNT 7.3)。
- 总体分析:FPD组死亡率更低(OR 0.57,95%CI 0.47-0.69,NNT 12.7),囊性PVL风险降低(OR 0.59,95%CI 0.41-0.85,NNT 27)。
- 总体分析:FPD降低插管、表面活性物质需求和机械通气率(OR分别为0.56[0.40-0.79]、0.67[0.55-0.82]、0.58[0.42-0.80]);气胸发生率相似(OR 0.82,95%CI 0.44-1.52)。
适用人群与场景
- 出生时需无创呼吸支持的新生儿;纳入比较定压装置(FPD;T型管或呼吸机)与手动驱动装置(HDPD;自动充气或气流充气复苏囊)的随机、准随机研究和前瞻性队列。
研究设计与关键结果
- 系统评价与Meta分析,纳入9项研究共3621名新生儿:5项RCT、2项含干预组合的RCT、2项前瞻性队列。
- 5项RCT的Meta分析:FPD组支气管肺发育不良风险降低(RR 0.68,95%CI 0.48-0.96,NNT 31)。
- 5项RCT:FPD组产房插管率降低(RR 0.72,95%CI 0.58-0.88,NNT 13.4),机械通气需求降低(RR 0.81,95%CI 0.67-0.96,NNT 17),机械通气时间缩短(MD -1.54天,95%CI -3.03至-0.05)。
- 5项RCT:FPD组表面活性物质需求降低(RR 0.79,95%CI 0.64-0.96,NNT 7.3)。
- 总体分析:FPD组死亡率更低(OR 0.57,95%CI 0.47-0.69,NNT 12.7)。
- 总体分析:FPD组插管率降低(OR 0.56,95%CI 0.40-0.79,NNT 7.5)、表面活性物质需求降低(OR 0.67,95%CI 0.55-0.82,NNT 10.7)、机械通气率降低(OR 0.58,95%CI 0.42-0.80,NNT 7.4)。
- 总体分析:FPD组囊性PVL风险降低(OR 0.59,95%CI 0.41-0.85,NNT 27);气胸发生率相似(OR 0.82,95%CI 0.44-1.52)。
证据类型、等级与局限
- 证据类型:系统评价与Meta分析,纳入5项RCT、2项含干预组合的RCT和2项前瞻性队列。
- 证据确定性:极低至中等(very low to moderate certainty of evidence)。
- 局限:原文报告需进一步研究以确认死亡率与cPVL下降的结果。
对床旁实践的改变
- 作者认为,出生时使用FPD复苏可改善呼吸过渡并降低BPD,证据确定性极低至中等。
- 作者认为,结果提示死亡率与cPVL下降,仍需进一步研究确认。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
UNLABELLED: Initial management of inadequate adaptation to extrauterine life relies on non-invasive respiratory support. Two types of devices are available: fixed pressure devices (FPD; T-pieces or ventilators) and hand driven pressure devices (HDPD; self- or flow-inflating bags). This systematic review and meta-analysis aims to compare clinical outcomes after neonatal resuscitation according to device type.
METHODS: Four databases were searched from inception to 2022, January. Search strategies included Mesh/Emtree terms as well as free language without any restriction. Randomized, quasi-randomized studies and prospective cohorts comparing the use of the two types of devices in neonatal resuscitation were included.
RESULTS: Nine studies recruiting 3621 newborns were included: 5 RCTs, 2 RCTs with interventions bundles and 2 prospective cohorts. Meta-analysis of the 5 RCTs demonstrated significant reductions in bronchopulmonary dysplasia (RR0,68[0,48-0,96]-NNT 31) and other respiratory outcomes: intubation in the delivery room (RR0,72[0,58-0,88]-NNT 13,4), mechanical ventilation requirements (RR0,81[0,67-0,96]-NNT 17) and duration (MD-1,54 days[-3,03- -0,05]), need for surfactant (RR0,79[0,64-0,96]-NNT 7,3). The overall analysis found a lower mortality in the FPD group (OR0,57[0,47-0,69]-NNT 12,7) and confirmed decreases in intubation, surfactant requirement and mechanical ventilation rates (OR 0,56[0,40-0,79]- NNT7,5; OR 0,67[0,55-0,82]-NNT10,7 and OR0,58[0,42-0,80]- NNT 7,4 respectively). The risk of cystic periventricular leukomalacia (cPVL) decreased significantly with FPD (OR0.59[0.41-0.85]-NNT 27). Pneumothorax rates were similar (OR0.82[0.44-1.52]).
CONCLUSION AND RELEVANCE: Resuscitation at birth with FPD improves respiratory transition and decreases BPD with a very low to moderate certainty of evidence. There is suggestion of decreases in mortality and cPVL. Further studies are still needed to confirm those results.
参考来源
- Tribolet S, Hennuy N, Rigo V, et al. Ventilation devices for neonatal resuscitation at birth: A systematic review and meta-analysis. Resuscitation. 2023. PMID: 36623747. doi:10.1016/j.resuscitation.2022.109681
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。