电阻抗成像引导的PEEP滴定降低ARDS机械功率:一项随机交叉先导试验
这项单中心随机交叉先导试验在中重度急性呼吸窘迫综合征机械通气患者中,比较电阻抗成像(EIT)引导的PEEP选择与High-PEEP/FiO2表选择PEEP。主要终点为每种PEEP选择策略后的机械功率变化。EIT较PEEP/FiO2表持续降低机械功率(平均差-4.36 J/min,95%CI -6.7~-1.95,p=0.002),并降低4ΔP+RR指数(-11.42 J/min,95%CI -19.01~-3.82,p=0.007),主要驱动于弹性动态功率下降(-1.61 J/min,95%CI -2.99~-0.22,p=0.027)。EIT还使设定PEEP、驱动压、峰值压、平台压降低,静态呼吸系统顺应性升高。
要点
- 中重度ARDS中,EIT引导PEEP较High-PEEP/FiO2表降低机械功率,平均差-4.36 J/min(95%CI -6.7~-1.95,p=0.002)。
- EIT引导PEEP降低4ΔP+RR指数-11.42 J/min(95%CI -19.01~-3.82,p=0.007),主要来自弹性动态功率下降-1.61 J/min(95%CI -2.99~-0.22,p=0.027)。
- EIT使设定PEEP降低2 cmH2O(p=0.046)、驱动压降低2.92 cmH2O(p=0.003)、平台压降低4.53 cmH2O(p=0.006)。
- EIT使静态呼吸系统顺应性升高7.93 ml/cmH2O(p=0.008),弹性静态功率和阻力功率无变化。
- 该研究为单中心随机交叉先导试验,结果需在更大样本中验证。
适用人群与场景
- 中重度急性呼吸窘迫综合征接受机械通气的患者。
处置流程与药物剂量
- EIT引导的PEEP选择:根据EIT检测和量化塌陷与过度膨胀来滴定PEEP,与High-PEEP/FiO2表选择PEEP进行比较。
研究设计与关键结果
- 单中心随机交叉先导试验,比较EIT引导PEEP选择与High-PEEP/FiO2表选择PEEP,主要终点为每种策略后的机械功率变化。
- EIT较PEEP/FiO2表降低机械功率,平均差-4.36 J/min(95%CI -6.7~-1.95,p=0.002)。
- EIT降低4ΔP+RR指数-11.42 J/min(95%CI -19.01~-3.82,p=0.007),主要驱动于弹性动态功率下降-1.61 J/min(95%CI -2.99~-0.22,p=0.027);弹性静态功率和阻力功率无变化。
- EIT使设定PEEP降低2 cmH2O(p=0.046)、驱动压降低2.92 cmH2O(p=0.003)、峰值压降低6.25 cmH2O(p=0.003)、平台压降低4.53 cmH2O(p=0.006)、静态呼吸系统顺应性升高7.93 ml/cmH2O(p=0.008)。
证据类型、等级与局限
- 证据类型:单中心随机交叉先导试验。
- 局限:原文未报告局限性。
对床旁实践的改变
- 在中重度ARDS机械通气患者中,EIT引导的PEEP滴定较High-PEEP/FiO2表可降低机械功率,主要来自弹性动态功率下降,同时降低驱动压和平台压、升高静态顺应性。
- 该研究为先导试验,作者未据此给出常规推荐。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: In patients with acute respiratory distress syndrome undergoing mechanical ventilation, positive end-expiratory pressure (PEEP) can lead to recruitment or overdistension. Current strategies utilized for PEEP titration do not permit the distinction. Electric impedance tomography (EIT) detects and quantifies the presence of both collapse and overdistension. We investigated whether using EIT-guided PEEP titration leads to decreased mechanical power compared to high-PEEP/FiO2 tables.
METHODS: A single-center, randomized crossover pilot trial comparing EIT-guided PEEP selection versus PEEP selection using the High-PEEP/FiO2 table in patients with moderate-severe acute respiratory distress syndrome. The primary outcome was the change in mechanical power after each PEEP selection strategy. Secondary outcomes included changes in the 4 × driving pressure + respiratory rate (4 ΔP, + RR index) index, driving pressure, plateau pressure, PaO2/FiO2 ratio, and static compliance.
RESULTS: EIT was consistently associated with a decrease in mechanical power compared to PEEP/FiO2 tables (mean difference - 4.36 J/min, 95% CI - 6.7, - 1.95, p = 0.002) and led to lower values in the 4ΔP + RR index (- 11.42 J/min, 95% CI - 19.01, - 3.82, p = 0.007) mainly driven by a decrease in the elastic-dynamic power (- 1.61 J/min, - 2.99, - 0.22, p = 0.027). The elastic-static and resistive powers were unchanged. Similarly, EIT led to a statistically significant change in set PEEP (- 2 cmH2O, p = 0.046), driving pressure, (- 2.92 cmH2O, p = 0.003), peak pressure (- 6.25 cmH2O, p = 0.003), plateau pressure (- 4.53 cmH2O, p = 0.006), and static respiratory system compliance (+ 7.93 ml/cmH2O, p = 0.008).
CONCLUSIONS: In patients with moderate-severe acute respiratory distress syndrome, EIT-guided PEEP titration reduces mechanical power mainly through a reduction in elastic-dynamic power. Trial registration This trial was prospectively registered on Clinicaltrials.gov (NCT03793842) on January 4th, 2019.
参考来源
- Jimenez JV, Munroe E, Weirauch AJ, et al. Electric impedance tomography-guided PEEP titration reduces mechanical power in ARDS: a randomized crossover pilot trial. Crit Care. 2023. PMID: 36650593. doi:10.1186/s13054-023-04315-x
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。