文献速递复苏、休克与脓毒症心脑血管急症

心脏骤停脉搏检查中多普勒超声收缩期峰值流速与呼气末二氧化碳的比较

Doppler ultrasound peak systolic velocity versus end tidal carbon dioxide during pulse checks in cardiac arrest.
PubMed 文献 · Resuscitation · 2023-01-13
一句话结论心脏骤停脉搏检查时,多普勒超声收缩期峰值流速与收缩压的相关性及检测ROSC(收缩压≥60 mmHg)的准确率均优于呼气末二氧化碳。

本研究为已发表前瞻性观察研究的二次分析,纳入急诊科心脏骤停、已建立高级气道和股动脉置管的患者,在每次脉搏检查时记录最高收缩压、最高多普勒超声收缩期峰值流速(PSV)及脉搏检查结束时的呼气末二氧化碳(ETCO2)。基于35例患者111次脉搏检查的数据,PSV与收缩压的相关系数高于ETCO2与收缩压(0.71 vs 0.31,p < 0.001)。PSV ≥ 20 cm/sec检测ROSC(收缩压≥60 mmHg)的准确率为89%(95% CI:82%-94%),高于ETCO2 ≥ 20 mmHg的59%(95% CI:49%-68%)和ETCO2 ≥ 25 mmHg的58%(95% CI:48%-67%)。作者认为,脉搏检查时多普勒超声PSV在与收缩压的相关性及检测ROSC的准确率方面均优于ETCO2。

要点

  • 在急诊科心脏骤停患者脉搏检查时,PSV与收缩压的相关系数为0.71,ETCO2与收缩压的相关系数为0.31(p < 0.001)。
  • PSV ≥ 20 cm/sec检测ROSC(收缩压≥60 mmHg)的准确率为89%(95% CI:82%-94%)。
  • ETCO2 ≥ 20 mmHg检测ROSC(收缩压≥60 mmHg)的准确率为59%(95% CI:49%-68%)。
  • ETCO2 ≥ 25 mmHg检测ROSC(收缩压≥60 mmHg)的准确率为58%(95% CI:48%-67%)。
  • 数据来自35例患者共111次脉搏检查,患者均已建立高级气道并置入股动脉导管。

适用人群与场景

  • 急诊科心脏骤停患者,已建立高级气道并置入股动脉导管。

诊断标准与关键阈值

  • ROSC定义为收缩压≥60 mmHg。
  • PSV阈值:≥20 cm/sec。
  • ETCO2阈值:≥20 mmHg或≥25 mmHg。

研究设计与关键结果

  • 研究类型:已发表前瞻性观察研究的二次分析;样本量:35例患者,111次脉搏检查。
  • PSV与收缩压的相关系数为0.71,ETCO2与收缩压的相关系数为0.31,两者比较p < 0.001。
  • PSV ≥ 20 cm/sec检测ROSC(收缩压≥60 mmHg)的准确率为89%(95% CI:82%-94%)。
  • ETCO2 ≥ 20 mmHg检测ROSC(收缩压≥60 mmHg)的准确率为59%(95% CI:49%-68%)。
  • ETCO2 ≥ 25 mmHg检测ROSC(收缩压≥60 mmHg)的准确率为58%(95% CI:48%-67%)。

证据类型、等级与局限

  • 证据类型:前瞻性观察研究的二次分析。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,脉搏检查时多普勒超声PSV在检测ROSC(收缩压≥60 mmHg)方面优于ETCO2。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: An accurate, non-invasive measure of return of spontaneous circulation (ROSC) is needed to improve management of cardiac arrest patients.

OBJECTIVES: During a pulse check in Emergency Department (ED) cardiac arrest patients, we compared the correlation between 1) end tidal carbon dioxide (ETCO2) and systolic blood pressure (SBP), and 2) Doppler ultrasound peak systolic velocity (PSV) and SBP. Additionally, we assessed the accuracy of PSV ≥ 20 cm/sec in comparison to previously suggested ETCO2 ≥ 20 or ≥ 25 mmHg thresholds to predict ROSC with SBP ≥ 60 mmHg.

METHODS: This was a secondary analysis of a previously published prospective observational study of ED cardiac arrest patients with an advanced airway and femoral arterial line in place. During each pulse check, highest SBP, highest PSV, and ETCO2 at the end of the pulse check were recorded. Spearman correlation coefficients were calculated and compared using a Fisher Z-transformation. Accuracy of previously determined PSV and ETCO2 thresholds for detecting ROSC with SBP ≥ 60 mmHg were compared using McNemar's tests.

RESULTS: Based on data from 35 patients with 111 pulse checks, we found a higher correlation between PSV and SBP than ETCO2 and SBP (0.71 vs 0.31; p < 0.001). Diagnostic accuracy of PSV ≥ 20 cm/sec for detecting ROSC with SBP ≥ 60 mmHg was 89% (95% CI: 82%-94%) versus 59% (95% CI: 49%-68%) and 58% (95% CI: 48%-67%) for ETCO2 ≥ 20 and ≥ 25 mmHg, respectively.

CONCLUSIONS: During a pulse check, Doppler ultrasound PSV outperformed ETCO2 for correlation with SBP and accuracy in detecting ROSC with SBP ≥ 60 mmHg.

来源:Resuscitation,查看原文。版权归原作者所有。