指南与共识呼吸衰竭与机械通气创伤与烧伤

专家共识小组关于选择最佳声门上气道装置纳入卫生员急救包的建议

Expert Consensus Panel Recommendations for Selection of the Optimal Supraglottic Airway Device for Inclusion to the Medic's Aid Bag.
指南 / 共识 · Med J (Ft Sam Houst Tex) · 2023-01-01
一句话结论专家共识小组8名成员中7人(88%)推荐凝胶套囊声门上气道装置纳入卫生员急救包,并强调需针对军事环境定制。

为选择最佳声门上气道(SGA)装置纳入卫生员急救包,组建了由8名院前专家、急诊医学专家和经验丰富的战斗卫生员组成的专家共识小组。小组会前独立复习了本团队已发表的研究(包括终端用户行动后回顾、市场分析、工程测试和战斗卫生员前瞻性反馈),召开虚拟会议后对首选3种装置(含军事定制设计选项)提出建议。结果显示,7/8(88%)推荐凝胶套囊SGA,5/8(62%)推荐自充气套囊SGA,5/8(62%)推荐喉管SGA;主要担忧为装置对军事环境的耐受性及运输中有效固定凝胶套囊和自充气套囊SGA的能力。结论为多数成员选择凝胶套囊SGA,并强调需军事专属定制以满足战斗环境需求。

要点

  • 8名专家中7人(88%)推荐凝胶套囊声门上气道装置纳入卫生员急救包。
  • 自充气套囊SGA和喉管SGA各获5/8(62%)推荐。
  • 专家主要担忧装置对军事环境的耐受性,以及运输中有效固定凝胶套囊和自充气套囊SGA的能力。
  • 多数专家选择凝胶套囊SGA,并强调需军事专属定制以支持战斗环境需求。

适用人群与场景

  • 战场环境下面临气道阻塞的伤员,由卫生员使用声门上气道装置进行气道管理。

研究设计与关键结果

  • 专家共识小组由8名院前专家、急诊医学专家和经验丰富的战斗卫生员组成,会前独立复习了本团队已发表的研究(终端用户行动后回顾分析、市场分析、工程测试和战斗卫生员前瞻性反馈),召开虚拟会议后对首选3种装置(含军事定制设计选项)提出建议。
  • 7/8(88%)专家推荐凝胶套囊SGA,5/8(62%)推荐自充气套囊SGA,5/8(62%)推荐喉管SGA。
  • 专家担忧主要涉及装置对军事环境的耐受性,以及运输中有效固定凝胶套囊SGA和自充气套囊SGA的能力。

证据类型、等级与局限

  • 证据类型:专家共识(专家共识小组推荐)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为多数专家选择凝胶套囊SGA,并强调需军事专属定制以支持战斗环境需求。

指南或共识出处

  • 专家共识小组建议,发布于《Med J (Ft Sam Houst Tex)》。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

INTRODUCTION: Airway obstruction is the second leading cause of potentially survivable death on the battlefield. The Committee on Tactical Combat Casualty Care (CoTCCC) has evolving recommendations for the optimal supraglottic airway (SGA) device for inclusion to the medics' aid bag.

METHODS: We convened an expert consensus panel consisting of a mix of 8 prehospital specialists, emergency medicine experts, and experienced combat medics, with the intent to offer recommendations for optimal SGA selection. Prior to meeting, we independently reviewed previously published studies conducted by our study team, conducted a virtual meeting, and summarized the findings to the panel. The studies included an analysis of end-user after action reviews, a market analysis, engineering testing, and prospective feedback from combat medics. The panel members then made recommendations regarding their top 3 choices of devices including the options of military custom design. Simple descriptive statistics were used to analyze panel recommendations.

RESULTS: The preponderance (7/8, 88%) of panel members recommended the gel-cuffed SGA, followed by the self-inflating-cuff SGA (5/8, 62%) and laryngeal tube SGA (5/8, 62%). Panel members expressed concerns primarily related to the (1) devices' tolerance for the military environment, and (2) ability to effectively secure the gel-cuffed SGA and the self-inflating-cuff SGA during transport.

CONCLUSIONS: A preponderance of panel members selected the gel-cuff SGA with substantial feedback highlighting the need for military-specific customizations to support the combat environment needs.

来源:Med J (Ft Sam Houst Tex),查看原文。版权归原作者所有。

参考来源

  1. Schauer SG, Tapia AD, Jeschke EA, et al. Expert Consensus Panel Recommendations for Selection of the Optimal Supraglottic Airway Device for Inclusion to the Medic's Aid Bag. Med J (Ft Sam Houst Tex). 2023. PMID: 36607306

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。