文献速递重症综合管理与镇静镇痛

超声引导下锁骨下腋静脉与颈内静脉置管在机械通气危重患者中的随机试验

Ultrasound-Guided Infraclavicular Axillary Vein Versus Internal Jugular Vein Cannulation in Critically Ill Mechanically Ventilated Patients: A Randomized Trial.
PubMed 文献 · Crit Care Med · 2022-12-07
一句话结论机械通气危重患者中,超声引导下锁骨下腋静脉平面内穿刺与颈内静脉平面外穿刺的穿刺和置管成功率、导管尖端异位及早期机械并发症均无差异。

这项前瞻性、单盲、开放标签、平行组随机试验在波兰两家大学附属ICU纳入机械通气且具中心静脉置管指征的危重患者,随机分为颈内静脉组(n=304)与腋静脉组(n=306),由麻醉与重症高级住院医师及顾问医师操作。颈内静脉组穿刺成功率100%、腋静脉组99.7%(卡方检验,p=0.19);置管成功率分别为98.7%与96.7%(卡方检验,p=0.11);导管尖端异位率分别为9.9%与10.1%(卡方检验,p=0.67);早期机械并发症率分别为3%与2.6%(卡方检验,p=0.79)。结论认为两种技术在机械通气危重患者中同样有效且安全。

要点

  • 颈内静脉组穿刺成功率100%,腋静脉组99.7%(卡方检验,p=0.19),两组无差异。
  • 置管成功率颈内静脉组98.7%,腋静脉组96.7%(卡方检验,p=0.11),两组无差异。
  • 导管尖端异位率颈内静脉组9.9%,腋静脉组10.1%(卡方检验,p=0.67),两组无差异。
  • 早期机械并发症率颈内静脉组3%(颈总动脉穿刺4例、血管周围血肿2例、椎动脉穿刺1例、气胸1例),腋静脉组2.6%(腋动脉穿刺4例、血管周围血肿4例)(卡方检验,p=0.79)。
  • 作者认为两种技术同样有效且安全,可用于机械通气危重患者。

适用人群与场景

  • 波兰两家大学附属ICU(奥波莱和卢布林)的机械通气危重患者,具有中心静脉置管临床指征。

处置流程与药物剂量

  • 颈内静脉组采用实时超声引导下平面外穿刺置管(n=304)。
  • 腋静脉组采用实时超声引导下锁骨下平面内穿刺置管(n=306)。
  • 所有置管由麻醉与重症高级住院医师及顾问医师操作。

研究设计与关键结果

  • 研究设计:前瞻性、单盲、开放标签、平行组随机试验,在波兰两家大学附属ICU进行,颈内静脉组n=304、腋静脉组n=306。
  • 穿刺成功率:颈内静脉组100%,腋静脉组99.7%(卡方检验,p=0.19)。
  • 置管成功率:颈内静脉组98.7%,腋静脉组96.7%(卡方检验,p=0.11)。
  • 导管尖端异位率:颈内静脉组9.9%,腋静脉组10.1%(卡方检验,p=0.67)。
  • 早期机械并发症率:颈内静脉组3%(颈总动脉穿刺4例、血管周围血肿2例、椎动脉穿刺1例、气胸1例),腋静脉组2.6%(腋动脉穿刺4例、血管周围血肿4例)(卡方检验,p=0.79)。

证据类型、等级与局限

  • 证据类型:前瞻性、单盲、开放标签、平行组随机试验。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,实时超声引导下颈内静脉平面外穿刺置管与锁骨下腋静脉平面内穿刺置管在机械通气危重患者中同样有效且安全,两种技术之间未发现差异。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: This clinical trial aimed to compare the ultrasound-guided in-plane infraclavicular cannulation of the axillary vein (AXV) and the ultrasound-guided out-of-plane cannulation of the internal jugular vein (IJV).

DESIGN: A prospective, single-blinded, open label, parallel-group, randomized trial.

SETTING: Two university-affiliated ICUs in Poland (Opole and Lublin).

PATIENTS: Mechanically ventilated intensive care patients with clinical indications for central venous line placement.

INTERVENTIONS: Patients were randomly assigned into two groups: the IJV group ( n = 304) and AXV group ( n = 306). The primary outcome was to compare the IJV group and AXV group through the venipuncture and catheterization success rates. Secondary outcomes were catheter tip malposition and early mechanical complication rates. All catheterizations were performed by advanced residents and consultants in anesthesiology and intensive care.

MEASUREMENTS AND MAIN RESULTS: The IJV puncture rate was 100%, and the AXV was 99.7% (chi-square, p = 0.19). The catheterization success rate in the IJV group was 98.7% and 96.7% in the AXV group (chi-square, p = 0.11). The catheter tip malposition rate was 9.9% in the IJV group and 10.1% in the AXV group (chi-square, p = 0.67). The early mechanical complication rate in the IJV group was 3% (common carotid artery puncture-4 cases, perivascular hematoma-2 cases, vertebral artery puncture-1 case, pneumothorax-1 case) and 2.6% in the AXV group (axillary artery puncture-4 cases, perivascular hematoma-4 cases) (chi-square, p = 0.79).

CONCLUSIONS: No difference was found between the real-time ultrasound-guided out-of-plane cannulation of the IJV and the infraclavicular real-time ultrasound-guided in-plane cannulation of the AXV. Both techniques are equally efficient and safe in mechanically ventilated critically ill patients.

来源:Crit Care Med,查看原文。版权归原作者所有。

参考来源

  1. Czarnik T, Czuczwar M, Borys M, et al. Ultrasound-Guided Infraclavicular Axillary Vein Versus Internal Jugular Vein Cannulation in Critically Ill Mechanically Ventilated Patients: A Randomized Trial. Crit Care Med. 2022. PMID: 36476809. doi:10.1097/CCM.0000000000005740

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。