文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

高流量氧疗在重症机械通气患者撤机后成功拔管中的价值

[Value of high-flow oxygen therapy after weaning for successful extubation of critical ill patients with mechanical ventilation].
PubMed 文献 · Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · 2022-01-01
一句话结论撤机后使用高流量氧疗可降低二氧化碳潴留发生率、减少撤机后再行机械通气比例、缩短撤机至拔管时间并降低拔管后72小时再插管率。

该回顾性研究纳入2018年1月至2020年6月浙江医院重症医学科收治的首次机械通气撤机患者,高流量氧疗组40例、文丘里面罩联合湿化器组37例。撤机后高流量组PaO2从6小时起、PaCO2从12小时起持续至24小时均显著低于文丘里组(均P<0.01)。高流量组撤机后再行机械通气率17.5%(7/40)vs 40.5%(15/37),拔管后72小时再插管率6.2%(2/32)vs 31.8%(7/22),撤机至拔管时间22.43±11.72小时 vs 28.07±10.42小时,均P<0.05。结论认为撤机后应用高流量氧疗可减少二氧化碳潴留、降低再行机械通气率、缩短拔管时间并降低再插管率。

要点

  • 高流量组撤机后再行机械通气率17.5%(7/40)显著低于文丘里组40.5%(15/37),P<0.05。
  • 高流量组拔管后72小时再插管率6.2%(2/32)显著低于文丘里组31.8%(7/22),P<0.05。
  • 高流量组撤机至拔管时间22.43±11.72小时显著短于文丘里组28.07±10.42小时,P<0.05。
  • 高流量组PaCO2在12、18、24小时均显著低于文丘里组(41.30±7.51 vs 47.42±7.54、40.97±6.98 vs 45.83±8.63、40.10±7.06 vs 46.14±9.15 mmHg,均P<0.01)。
  • 两组各时间点HR、SBP、DBP、SpO2无显著差异,撤机后生命体征均稳定。

适用人群与场景

  • 浙江医院重症医学科2018年1月至2020年6月收治的首次机械通气撤机患者,年龄大于18岁,原发病为脑血管意外、外科手术、心血管疾病和肺炎。
  • 高流量氧疗组40例,文丘里面罩联合湿化器组37例。

处置流程与药物剂量

  • 撤机后高流量氧疗组接受高流量氧疗,文丘里组接受文丘里面罩联合湿化器。
  • 撤机后监测0、6、12、18、24小时HR、血压、SpO2,6、12、18、24小时动脉血气pH、PaO2、PaCO2。

研究设计与关键结果

  • 研究类型为回顾性研究,纳入首次机械通气撤机患者77例(高流量组40例、文丘里组37例),两组性别、年龄、原发病、严重程度评分、撤机前机械通气时间等基线资料无显著差异。
  • 撤机后高流量组PaO2从6小时起、PaCO2从12小时起持续至24小时均显著低于文丘里组:PaO2 6小时112.34±38.25 vs 156.76±68.44 mmHg,12小时110.92±38.66 vs 150.64±59.07 mmHg,18小时111.12±36.77 vs 141.30±39.05 mmHg,24小时110.82±39.37 vs 139.65±41.50 mmHg;PaCO2 12小时41.30±7.51 vs 47.42±7.54 mmHg,18小时40.97±6.98 vs 45.83±8.63 mmHg,24小时40.10±7.06 vs 46.14±9.15 mmHg,均P<0.01。
  • 文丘里组撤机后PaO2逐渐下降,PaCO2在12小时明显升高、12小时后缓慢下降;高流量组pH及PaO2、PaCO2波动不明显。
  • 高流量组撤机后再行机械通气率17.5%(7/40)显著低于文丘里组40.5%(15/37),P<0.05。
  • 高流量组拔管后72小时再插管率6.2%(2/32)显著低于文丘里组31.8%(7/22),P<0.05。
  • 高流量组撤机至拔管时间22.43±11.72小时显著短于文丘里组28.07±10.42小时,P<0.05。
  • 两组各时间点HR、SBP、DBP、SpO2无显著差异。

证据类型、等级与局限

  • 证据类型:回顾性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,对重症机械通气患者拔管过程使用高流量氧疗可减少二氧化碳潴留发生率、降低撤机后再行机械通气率、缩短撤机至拔管时间并降低拔管后72小时再插管率。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the value of high-flow oxygen therapy after weaning in successful extubation of critically ill patients with mechanical ventilation.

METHODS: A retrospective study was conducted. The weaned patients who were older than 18 years old and underwent mechanical ventilation for the first time due to cerebrovascular accidents, surgical operations, cardiovascular diseases, and pneumonia admitted to the department of critical care medicine of Zhejiang Hospital from January 2018 to June 2020 were enrolled. Among the patients, 40 cases received high-flow oxygen therapy after weaning, and 37 cases received Venturi combined with the humidifier. The patient's gender, age, primary disease, severity score, duration of mechanical ventilation before weaning, heart rate (HR), blood pressure, pulse oxygen saturation (SpO2) at 0, 6, 12, 18, and 24 hours after weaning, and pH value, arterial partial pressure of oxygen (PaO2), arterial partial pressure of carbon dioxide (PaCO2) at 6, 12, 18, and 24 hours after weaning, the rate of performing mechanical ventilation after weaning, extubation time after weaning, and the rate of reintubation after extubation for 72 hours were collected.

RESULTS: There was no significant difference in baseline data such as gender, age, primary disease, severity score, and duration of mechanical ventilation before weaning between the two groups. After weaning, the vital signs of the two groups were stable, and there was no significant difference in HR, systolic blood pressure (SBP), diastolic blood pressure (DBP) or SpO2 at each time point between the two groups. After weaning, the pH of arterial blood gas analysis in the two groups and the fluctuations of PaO2 and PaCO2 in the high-flow group were not obvious. In the Venturi group, PaO2 gradually decreased after weaning, PaCO2 increased significantly at 12 hours, and slowly decreased after 12 hours. The PaO2 from 6 hours and PaCO2 from 12 hours in the high-flow group were significantly lower than those in the Venturi group, and continued to 24 hours [PaO2 (mmHg, 1 mmHg ≈ 0.133 kPa): 112.34±38.25 vs. 156.76±68.44 at 6 hours, 110.92±38.66 vs. 150.64±59.07 at 12 hours, 111.12±36.77 vs. 141.30±39.05 at 18 hours, 110.82±39.37 vs. 139.65±41.50 at 24 hours; PaCO2 (mmHg): 41.30±7.51 vs. 47.42±7.54 at 12 hours, 40.97±6.98 vs. 45.83±8.63 at 18 hours, 40.10±7.06 vs. 46.14±9.15 at 24 hours, all P < 0.01]. The rate of performed mechanical ventilation after weaning and the rate of reintubation after extubation for 72 hours in the high-flow group were significantly lower than those in the Venturi group [17.5% (7/40) vs. 40.5% (15/37), 6.2% (2/32) vs. 31.8% (7/22), both P < 0.05], and the extubation time after weaning was significantly shorter than that in the Venturi group (hours: 22.43±11.72 vs. 28.07±10.42, P < 0.05).

CONCLUSIONS: Using high-flow oxygen therapy to the extubation process of critically ill mechanical ventilation patients can reduce the incidence of carbon dioxide retention and the rate of performed mechanical ventilation after weaning, shorten the extubation time after weaning, and reduce the rate of reintubation after extubation for 72 hours.

来源:Zhonghua Wei Zhong Bing Ji Jiu Yi Xue,查看原文。版权归原作者所有。

参考来源

  1. Sun W, Ren Q, Wu L, et al. [Value of high-flow oxygen therapy after weaning for successful extubation of critical ill patients with mechanical ventilation]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2022. PMID: 36567556. doi:10.3760/cma.j.cn121430-20210309-00353

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。