高流量氧疗与T管通气策略在自主呼吸试验中对机械通气患者脱机失败的影响:一项随机对照试验
该单中心随机对照试验于2019年6月至2022年1月在符合脱机准备标准的机械通气≥12小时患者中比较T管SBT与高流量氧疗SBT。108例患者随机分组,每组54例。主要终点第2天脱机失败率两组无显著差异(高流量组5.6% vs T管组9.3%,差值3.7%[95%CI -6.1-13.6],p=0.713);第7天脱机失败率亦无显著差异(13.0% vs 24.1%,差值11.1%[95%CI -3.4-25.6],p=0.215)。事后亚组分析显示,因呼吸衰竭插管的患者中高流量氧疗SBT与第7天脱机失败率较低相关(OR 0.17[95%CI 0.04-0.78],交互作用p=0.020)。ICU及住院时间、死亡率两组无显著差异,研究期间未记录严重不良事件。作者认为研究可能把握度不足,且简单脱机患者比例较高、脱机失败率低于预期。
要点
- 高流量氧疗SBT与T管SBT相比,第2天脱机失败率无显著差异:高流量组5.6%(3例)vs T管组9.3%(5例),差值3.7%(95%CI -6.1-13.6),p=0.713。
- 第7天脱机失败率两组无显著差异:高流量组13.0%(7例)vs T管组24.1%(13例),差值11.1%(95%CI -3.4-25.6),p=0.215。
- 事后亚组分析:因呼吸衰竭插管的患者中,高流量氧疗SBT与第7天脱机失败率较低相关(OR 0.17[95%CI 0.04-0.78]),交互作用p=0.020。
- ICU及住院时间、ICU及院内死亡率两组无显著差异;研究期间未记录严重不良事件。
- 作者认为研究可能把握度不足,且简单脱机患者比例较高、脱机失败率低于预期,解读结果时应考虑。
适用人群与场景
- 在单中心内科ICU接受机械通气≥12小时且符合脱机准备标准的患者。
- 平均年龄67.0±11.1岁,男性占64.8%。
诊断标准与关键阈值
- 自主呼吸试验(SBT)用于判断患者是否可拔管;纳入患者需符合脱机准备标准。
处置流程与药物剂量
- 患者随机接受T管SBT或高流量氧疗SBT。
研究设计与关键结果
- 研究类型:随机对照试验;单中心;2019年6月至2022年1月;108例患者(T管组54例,高流量组54例)。
- 主要终点第2天脱机失败:T管组5例(9.3%)vs 高流量组3例(5.6%),差值3.7%(95%CI -6.1-13.6),p=0.713。
- 次要终点第7天脱机失败:T管组13例(24.1%)vs 高流量组7例(13.0%),差值11.1%(95%CI -3.4-25.6),p=0.215。
- 事后亚组分析:因呼吸衰竭插管的患者中,高流量氧疗SBT与第7天脱机失败率较低相关(OR 0.17[95%CI 0.04-0.78]),交互作用p=0.020。
- ICU及住院时间、ICU及院内死亡率两组无显著差异;研究期间未记录严重不良事件。
证据类型、等级与局限
- 证据类型:随机对照试验。
- 局限:作者认为研究可能把握度不足,无法检出高流量氧疗SBT与T管SBT比较的临床重要治疗效应;简单脱机患者比例较高、脱机失败率低于预期,解读结果时应考虑。
对床旁实践的改变
- 作者认为,在机械通气患者中,高流量氧疗SBT与T管SBT相比未显著降低脱机失败风险。
- 事后亚组分析提示,因呼吸衰竭插管的患者中高流量氧疗SBT可能与第7天脱机失败率较低相关(OR 0.17[95%CI 0.04-0.78]),交互作用p=0.020。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: A spontaneous breathing trial (SBT) is used to determine whether patients are ready for extubation, but the best method for choosing the SBT strategy remains controversial. We investigated the effect of high-flow oxygen versus T-piece ventilation strategies during SBT on rates of weaning failure among patients receiving mechanical ventilation.
METHODS: This randomized clinical trial was conducted from June 2019 through January 2022 among patients receiving mechanical ventilation for ≥ 12 h who fulfilled the weaning readiness criteria at a single-center medical intensive care unit. Patients were randomized to undergo either T-piece SBT or high-flow oxygen SBT. The primary outcome was weaning failure on day 2, and the secondary outcomes were weaning failure on day 7, ICU and hospital length of stay, and ICU and in-hospital morality.
RESULTS: Of 108 patients (mean age, 67.0 ± 11.1 years; 64.8% men), 54 received T-piece SBT and 54 received high-flow oxygen SBT. Weaning failure on day 2 occurred in 5 patients (9.3%) in the T-piece group and 3 patients (5.6%) in the high-flow group (difference, 3.7% [95% CI, - 6.1-13.6]; p = 0.713). Weaning failure on day 7 occurred in 13 patients (24.1%) in the T-piece group and 7 patients (13.0%) in the high-flow group (difference, 11.1% [95% CI, - 3.4-25.6]; p = 0.215). A post hoc subgroup analysis showed that high-flow oxygen SBT was significantly associated with a lower rate of weaning failure on day 7 (OR, 0.17 [95% CI, 0.04-0.78]) among those patients intubated because of respiratory failure (p for interaction = 0.020). The ICU and hospital length of stay and mortality rates did not differ significantly between the two groups. During the study, no serious adverse events were recorded.
CONCLUSIONS: Among patients receiving mechanical ventilation, high-flow oxygen SBT did not significantly reduce the risk of weaning failure compared with T-piece SBT. However, the study may have been underpowered to detect a clinically important treatment effect for the comparison of high-flow oxygen SBT versus T-piece SBT, and a higher percentage of patients with simple weaning and a lower weaning failure rate than expected should be considered when interpreting the findings. Clinical trial registration This trial was registered with ClinicalTrials.gov (number NCT03929328) on April 26, 2019.
参考来源
- Lee HY, Lee J, Lee SM, et al. Effect of high-flow oxygen versus T-piece ventilation strategies during spontaneous breathing trials on weaning failure among patients receiving mechanical ventilation: a randomized controlled trial. Crit Care. 2022. PMID: 36564808. doi:10.1186/s13054-022-04281-w
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。