文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

肥胖及重度肥胖机械通气依赖呼吸衰竭患者中,驱动压与弹性升高不增加院内死亡率

Elevated Driving Pressure and Elastance Does Not Increase In-Hospital Mortality Among Obese and Severely Obese Patients With Ventilator Dependent Respiratory Failure.
PubMed 文献 · Crit Care Explor · 2022-12-12
一句话结论肥胖及重度肥胖VDRF患者驱动压≥15 cm H2O和总呼吸系统弹性≥2 cm H2O/(mL/kg)更常见,但院内死亡率、无呼吸机天数及ICU住院时间与正常/超重组无差异。

该回顾性观察性队列研究利用2016-2018年两家三级学术医学中心的电子健康记录,纳入3204例内科和外科ICU机械通气患者,按BMI分层比较驱动压(DP)和总呼吸系统弹性(Ers)及临床结局。重度肥胖与DP≥15 cm H2O(RR 1.51,95%CI 1.26-1.82)和Ers≥2 cm H2O/(mL/kg)(RR 1.31,95%CI 1.14-1.49)相关。尽管DP和Ers升高,三组院内死亡率、无呼吸机天数和ICU住院时间均无差异。作者认为DP在肥胖及重度肥胖VDRF患者中预后价值较低。

要点

  • 重度肥胖VDRF患者发生DP≥15 cm H2O的风险是正常/超重组的1.51倍(RR 1.51,95%CI 1.26-1.82)。
  • 重度肥胖VDRF患者发生Ers≥2 cm H2O/(mL/kg)的风险是正常/超重组的1.31倍(RR 1.31,95%CI 1.14-1.49)。
  • 肥胖及重度肥胖VDRF患者尽管DP和Ers升高,院内死亡率、无呼吸机天数及ICU住院时间与正常/超重组无差异。
  • 作者认为驱动压对肥胖及重度肥胖VDRF患者的预后价值较低。

适用人群与场景

  • 2016-2018年两家三级学术医学中心内科和外科ICU的机械通气患者,使用机械通气前2个完整日的电子健康记录数据。
  • 按BMI分层:正常/超重(BMI<30 kg/m2)、肥胖、重度肥胖。

诊断标准与关键阈值

  • 驱动压(DP)阈值:≥15 cm H2O。
  • 总呼吸系统弹性(Ers)阈值:≥2 cm H2O/(mL/kg)。

研究设计与关键结果

  • 研究类型:回顾性观察性队列研究,纳入3204例机械通气患者,其中肥胖976例(30.4%),重度肥胖382例(11.9%)。
  • 重度肥胖与DP≥15 cm H2O相关(RR 1.51,95%CI 1.26-1.82),与Ers≥2 cm H2O/(mL/kg)相关(RR 1.31,95%CI 1.14-1.49)。
  • 三组院内死亡率、无呼吸机天数及ICU住院时间无差异。

证据类型、等级与局限

  • 证据类型:回顾性观察性队列研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为驱动压对肥胖及重度肥胖VDRF患者的预后价值较低。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

UNLABELLED: Existing recommendations for mechanical ventilation are based on studies that under-sampled or excluded obese and severely obese individuals.

OBJECTIVE: To determine if driving pressure (DP) and total respiratory system elastance (Ers) differ among normal/overweight (body mass index [BMI] < 30 kg/m2), obese, and severely obese ventilator-dependent respiratory failure (VDRF) patients and if there any associations with clinical outcomes.

DESIGN SETTING AND PARTICIPANTS: Retrospective observational cohort study during 2016-2018 at two tertiary care academic medical centers using electronic health record data from the first 2 full days of mechanical ventilation. The cohort was stratified by BMI classes to measure median DP, time-weighted mean tidal volume, plateau pressure, and Ers for each BMI class.

SETTING AND PARTICIPANTS: Mechanically ventilated patients in medical and surgical ICUs.

MAIN OUTCOMES AND MEASURES: Primary outcome and effect measures included relative risk of in-hospital mortality, ventilator-free days, ICU length of stay, and hospital length of stay with multivariable adjustment.

RESULTS: The cohort included 3,204 patients with 976 (30.4%) and 382 (11.9%) obese and severely obese patients, respectively. Severe obesity was associated with a DP greater than or equal to 15 cm H2O (relative risk [RR], 1.51 [95% CI, 1.26-1.82]) and Ers greater than or equal to 2 cm H2O/(mL/kg) (RR, 1.31 [95% CI, 1.14-1.49]). Despite elevated DP and Ers, there were no differences in in-hospital mortality, ventilator-free days, or ICU length of stay among all three groups.

CONCLUSIONS AND RELEVANCE: Despite higher DP and ERS among obese and severely obese VDRF patients, there were no differences in in-hospital mortality or duration of mechanical ventilation, suggesting that DP has less prognostic value in obese and severely obese VDRF patients.

来源:Crit Care Explor,查看原文。版权归原作者所有。

参考来源

  1. Terry C, Brinton D, Simpson AN, et al. Elevated Driving Pressure and Elastance Does Not Increase In-Hospital Mortality Among Obese and Severely Obese Patients With Ventilator Dependent Respiratory Failure. Crit Care Explor. 2022. PMID: 36583205. doi:10.1097/CCE.0000000000000811

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。