文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛心脑血管急症

急性呼吸窘迫综合征患者高肺动脉压相关的机械通气变量:一项事后分析

Mechanical ventilation variables associated with high pulmonary artery pressures in ARDS patients: a post hoc analysis.
PubMed 文献 · Crit Care · 2022-12-21
一句话结论在ARDS合并肺动脉高压患者中,呼吸频率超过17次/分与平均肺动脉压递增相关,而增加潮气量(在驱动压<18 cmH2O限制内)可能是更保护右心的控制CO2和pH的方式。

该研究为FACTT试验的事后分析,纳入置入肺动脉导管并有肺动脉压读数的ARDS患者(排除自主呼吸者),通过单因素、多因素及非线性分析评估机械通气参数与平均肺动脉压(mPAP)的关联。多因素分析显示血pH、P/F比值、PaCO2、平均气道压及以顺应性标化的机械功率与mPAP独立相关。非线性分析中,机械功率(p=0.01)、呼吸频率(p=0.04)、峰压(p=0.03)和平均气道压(p=0.01)以分数多项式模型拟合最佳,呼吸频率16.8次/分和机械功率8.8 J/min为拐点。作者认为,经典ARDS肺保护策略(低潮气量、允许性高碳酸血症)可能对合并右心功能障碍或急性肺心病亚组产生不利影响。

要点

  • 在置入肺动脉导管的ARDS患者中,呼吸频率超过17次/分与mPAP递增相关(非线性分析拐点16.8次/分,p=0.04)。
  • 机械功率与mPAP呈非线性关联,拐点为8.8 J/min(p=0.01 vs 线性模型)。
  • 多因素分析中,血pH、P/F比值、PaCO2、平均气道压及以顺应性标化的机械功率与mPAP独立相关。
  • 作者认为,增加潮气量(在驱动压<18 cmH2O限制内)可能是更保护右心的控制CO2和pH的方式。
  • 经典ARDS肺保护策略(低潮气量、允许性高碳酸血症)可能对合并右心功能障碍或急性肺心病的ARDS亚组产生不利影响。

适用人群与场景

  • FACTT试验数据库中置入肺动脉导管(PAC)并有肺动脉压读数的ARDS患者。
  • 排除置入PAC但自主呼吸的患者,因驱动压和机械功率在该队列中未经验证。

研究设计与关键结果

  • 研究类型:FACTT试验的事后分析。
  • 单因素分析中,除潮气量(校正呼吸频率后)外,所有通气参数均与mPAP显著相关。
  • 多因素分析显示血pH、P/F比值、PaCO2、平均气道压及以顺应性标化的机械功率与mPAP独立相关。
  • 非线性分析中,机械功率(p=0.01 vs 线性模型)、呼吸频率(p=0.04)、峰压(p=0.03)和平均气道压(p=0.01)以分数多项式模型拟合最佳。
  • 呼吸频率拐点为16.8次/分,机械功率拐点为8.8 J/min。

证据类型、等级与局限

  • 证据类型:FACTT试验的事后分析。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,经典ARDS肺保护策略(包括低潮气量通气和允许性高碳酸血症)可能对合并右心功能障碍或急性肺心病的ARDS亚组患者的管理产生不利影响。
  • 作者认为,呼吸频率高于17次/分会显示mPAP递增。
  • 作者认为,增加潮气量(在驱动压<18 cmH2O限制内)可能是更保护右心的控制CO2和pH的方式。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: The relationship between indices of mechanical ventilation and pulmonary artery pressures remains ill-defined in ARDS. As our understanding of mechanical ventilation has progressed, there is now a greater appreciation of the impact of high driving pressures and mechanical power in perpetuating lung injury. However, the relationship between the newer derived indices of mechanical ventilation and pulmonary artery pressure is unclear. We performed a post hoc analysis of the Fluid and Catheters Treatment Trial (FACTT) trial to investigate the associations between mechanical ventilation indices in ARDS patients and the prevalence of pulmonary hypertension. This may help elucidate future clinical targets for more, right ventricular protective, mechanical ventilation strategies.

METHODS: We performed a post hoc analysis of the FACTT database to identify ARDS patients who had a pulmonary artery catheter (PAC) inserted and pulmonary artery pressure readings recorded. We excluded any patient with a PAC inserted who was spontaneously breathing, as driving pressure and mechanical power are not validated in this cohort. Three independent analyses were performed: a univariate analysis, to assess for associations between mPAP and mechanical ventilation parameters using Pearson correlation coefficients, a multivariate analysis, to assess for independent associations with mPAP using a multiple regression model according to Akaike's information criteria and finally an analysis for nonlinearity, using the best-fitting model according to the Bayesian information criterion (BIC) from linear, quadratic, fractional polynomial and restricted cubic spline models.

RESULTS: All the ventilation parameters demonstrated a significant correlation with mPAP, except tidal volume (once adjusted for respiratory rate) in the univariate analysis. The multivariate analysis demonstrated that the blood pH level, P/F ratio, PaCO2 level, mean airway pressure and the mechanical power indexed to compliance were independently associated with mPAP. In the final nonlinear analysis, associations did not differ from linearity except for 4 variables for which the fractional polynomial was the best-fitting model. These were mechanical power (p = 0.01 compared to the linear model), respiratory rate (p = 0.04), peak pressure (p = 0.03) and mean airway pressure (p = 0.01). Two nonlinear variables associated with mPAP were assessed in more detail, respiratory rate and mechanical power. Inflexion points at a respiratory rate of 16.8 cycles per minute and a mechanical power of 8.8 J/min were demonstrated.

CONCLUSIONS: The associations identified between mPAP and mechanical ventilation variables in this analysis would suggest that classical ARDS lung protective strategies, including low tidal volume ventilation and permissive hypercapnia, may negatively impact the management of the subset of ARDS patients with associated right ventricular dysfunction or ACP. Additionally, respiratory rates above 17 cycles per minute show an incremental increase in mPAP. Therefore, increases in tidal volume (within the limitation of driving pressure < 18 cmH20) may represent a more right ventricular protective way to control CO2 and pH.

来源:Crit Care,查看原文。版权归原作者所有。

参考来源

  1. Riddell JR, Jones BJ, Fernandes BM, et al. Mechanical ventilation variables associated with high pulmonary artery pressures in ARDS patients: a post hoc analysis. Crit Care. 2022. PMID: 36544201. doi:10.1186/s13054-022-04282-9

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。