院外心脏骤停复苏中二氧化碳波形图测量的通气频率及其与自主循环恢复的关系
该回顾性观察性队列研究纳入两年期间全部院外心脏骤停(OHCA)患者,排除创伤和儿科患者,采用无创连续二氧化碳波形图记录通气并由盲法医学培训人员手动标注,分析通气频率与自主循环恢复的关系。共790例OHCA中仅386例(49%)有可用二氧化碳波形图数据,最终队列314例;中位通气频率为7次/分(IQR 5.4-8.5),仅70例(22%)达到指南推荐的8-10次/分;62例(20%)达到主要结局。单变量和多变量逻辑回归模型均未观察到任何通气参数与患者结局之间的统计学显著关联。作者结论为未能检测到关联,二氧化碳波形图作为通气频率测量工具可靠性差,达到指南推荐通气频率仍具挑战性。
要点
- 在314例可评估的OHCA患者中,中位通气频率为7次/分(IQR 5.4-8.5),仅70例(22%)达到指南推荐的8-10次/分。
- 62例(20%)达到主要结局(持续院前自主循环恢复),但单变量和多变量逻辑回归模型均未观察到通气参数与结局之间的统计学显著关联。
- 790例OHCA中仅386例(49%)有可用二氧化碳波形图数据,提示二氧化碳波形图作为通气频率测量工具的可靠性差。
- 作者结论:未能检测到骤停期间通气频率与近端患者结局之间的关联,达到指南推荐通气频率仍具挑战性。
适用人群与场景
- 两年期间全部院外心脏骤停(OHCA)患者,排除创伤和儿科患者。
- 仅386例(49%)有可用二氧化碳波形图数据,应用纳入和排除标准后最终研究队列为314例。
研究设计与关键结果
- 研究类型:回顾性观察性队列研究;共790例OHCA,仅386例(49%)有可用二氧化碳波形图数据,最终研究队列314例。
- 通气记录采用无创连续二氧化碳波形图,由盲法医学培训团队成员手动标注所有通气,采用四种技术分析通气频率。
- 中位通气频率为7次/分(IQR 5.4-8.5);仅70例(22%)达到指南推荐的8-10次/分。
- 主要结局为持续院前自主循环恢复,62例(20%)达到;次要结局为院前救治结束时生命状态和存活至入院。
- 单变量和多变量逻辑回归模型均未观察到任何通气参数与患者结局之间的统计学显著关联。
证据类型、等级与局限
- 证据类型:回顾性观察性队列研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者结论:未能检测到连续二氧化碳波形图测量的骤停期间通气频率与OHCA近端患者结局之间的关联。
- 作者结论:二氧化碳波形图作为通气频率测量工具可靠性差。
- 作者结论:达到指南推荐的通气频率仍具挑战性。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Clinical guidelines for adult out-of-hospital cardiac arrest (OHCA) recommend a ventilation rate of 8-10 per minute yet acknowledge that few data exist to guide recommendations. The goal of this study was to evaluate the utility of continuous capnography to measure ventilation rates and the association with return of spontaneous circulation (ROSC).
METHODS: This was a retrospective observational cohort study. We included all OHCA during a two-year period and excluded traumatic and pediatric patients. Ventilations were recorded using non-invasive continuous capnography. Blinded medically trained team members manually annotated all ventilations. Four techniques were used to analyze ventilation rate. The primary outcome was sustained prehospital ROSC. Secondary outcomes were vital status at the end of prehospital care and survival to hospital admission. Univariable and multivariable logistic regression models were constructed.
RESULTS: A total of 790 OHCA were analyzed. Only 386 (49%) had useable capnography data. After applying inclusion and exclusion criteria, the final study cohort was 314 patients. The median ventilation rate per minute was 7 (IQR 5.4-8.5). Only 70 (22%) received a guideline-compliant ventilation rate of 8-10 per minute. Sixty-two (20%) achieved the primary outcome. No statistically significant associations were observed between any of the ventilation parameters and patient outcomes in both univariable and multivariable logistic regression models.
CONCLUSIONS: We failed to detect an association between intra-arrest ventilation rates measured by continuous capnography and proximal patient outcomes after OHCA. Capnography has poor reliability as a measure of ventilation rate. Achieving guideline-compliant ventilation rates remains challenging.
参考来源
- Benoit JL, Lakshmanan S, Farmer SJ, et al. Ventilation rates measured by capnography during out-of-hospital cardiac arrest resuscitations and their association with return of spontaneous circulation. Resuscitation. 2022. PMID: 36481240. doi:10.1016/j.resuscitation.2022.11.028
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。