文献速递复苏、休克与脓毒症心脑血管急症重症综合管理与镇静镇痛

电针百会穴改善心脏骤停后综合征大鼠神经功能缺损与血流动力学稳定性

[Effect of electroacupuncture at Baihui ameliorated neurologic deficit and hemodynamic stability in rat model of post-cardiac arrest syndrome].
PubMed 文献 · Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · 2022-01-01
一句话结论大鼠窒息性心脏骤停模型中,复苏后电针百会穴可升高MAP、降低海马CA1神经元凋亡率与S100B,但未改善72小时生存率,作者认为其机制有待进一步验证。

研究将107只雄性SD大鼠随机分为假手术组、心脏骤停(CA)组和电针(EA)组,CA组与EA组经气管夹闭建立窒息性心脏骤停模型,ROSC后CA组接受基础呼吸支持与液体复苏,EA组在此基础上于百会穴行电针(疏密波4-20 Hz,电流以引起头皮抽动为最小强度,疗程30分钟)。结果显示EA组ROSC后15分钟MAP显著高于CA组,ROSC后6小时海马CA1区神经元凋亡率及血清S100B显著低于CA组,NDS与假手术组无显著差异;但EA未降低TNF-α、IL-6,也未改善72小时生存率(假手术组100%、CA组25%、EA组30%,P>0.05)。作者认为电针百会穴可稳定血流动力学并具有一定神经保护作用,但不减轻全身炎症反应、不提高生存率,机制尚待进一步研究。

要点

  • ROSC后15分钟,EA组MAP为125.00(94.00,136.25)mmHg,CA组为92.00(72.00,122.50)mmHg,EA组显著升高(P<0.05)。
  • ROSC后6小时海马CA1区神经元凋亡率EA组(62.84±2.67)% vs CA组(71.29±3.70)%,EA组显著降低(P<0.05)。
  • ROSC后6小时血清S100B EA组19.30±13.87 ng/L vs CA组132.28±31.67 ng/L,EA组显著降低(P<0.05)。
  • 72小时生存率假手术组100%、CA组25%、EA组30%,EA未改善生存率(P>0.05)。
  • EA组与CA组TNF-α、IL-6水平无显著差异,EA未减轻全身炎症反应。

适用人群与场景

  • 雄性SD大鼠窒息性心脏骤停模型,共107只,随机分为假手术组、CA组和EA组;假手术组不诱导窒息。

处置流程与药物剂量

  • EA组在CA组治疗(ROSC后基础呼吸支持与液体复苏)基础上,于百会穴行电针,疏密波频率4-20 Hz,电流强度调至最小以引起头皮抽动,疗程30分钟。

研究设计与关键结果

  • 研究类型为动物实验,107只雄性SD大鼠随机分为假手术组、CA组和EA组;CA组与EA组经气管夹闭建立窒息性心脏骤停模型。
  • ROSC后15分钟MAP:EA组125.00(94.00,136.25)mmHg vs CA组92.00(72.00,122.50)mmHg,EA组显著升高(P<0.05)。
  • ROSC后6小时NDS:CA组46.00±10.61 vs 假手术组80.00±0.00,CA组显著低于假手术组(P<0.05);EA组与假手术组无显著差异。
  • 72小时生存率:假手术组100%、CA组25%、EA组30%,EA未改善生存率(P>0.05)。
  • ROSC后6小时海马CA1区神经元凋亡率:EA组(62.84±2.67)% vs CA组(71.29±3.70)%,EA组显著降低(P<0.05)。
  • ROSC后6小时血清S100B:EA组19.30±13.87 ng/L vs CA组132.28±31.67 ng/L,EA组显著降低(P<0.05);TNF-α和IL-6两组无显著差异。

证据类型、等级与局限

  • 证据类型:动物实验(大鼠窒息性心脏骤停模型)。
  • 局限:作者指出电针百会穴不减轻全身炎症反应、不提高生存率,其机制尚待进一步研究验证。

对床旁实践的改变

  • 作者认为,电针百会穴可稳定心脏骤停后综合征大鼠的血流动力学,并具有一定神经保护作用,但不减轻全身炎症反应、不改善生存率。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To observe the results of electroacupuncture (EA) on the resuscitation of a rat model of asphyxia cardiac arrest (CA). And to explore its effect on the neurologic deficits and hemodynamic instability of post-cardiac arrest syndrome (PCAS).

METHODS: A total of 107 male SD rats were randomly divided into sham, CA, and EA groups. Each group received arterial catheterization and tracheal intubation. The sham group was not induced asphyxia. Asphyxial cardiac arrest was established by endotracheal tube clamping. Rats in the CA group received basic respiratory support and fluid resuscitation in return of spontaneous circulation (ROSC) and rats in the EA group received EA at Baihui based on the treatment of CA group after ROSC, with a dense-dispersed wave at frequencies of 4-20 Hz, while the current intensity was adjusted minimum to induce a twitch of the scalp, the course of treatment was 30 minutes. The baseline data, hemodynamics after ROSC, neurological deficit score (NDS), pathological changes of brain tissue, and levels of serum biomarker were recorded and compared among the three groups. The 72-hour survival of rats was analyzed by Kaplan-Meier survival curve. Hematoxylin-eosin (HE) staining was used to observe the pathological changes of necrotic neurons in the hippocampal CA1 region of rat brain. Meanwhile, Nissl staining and TdT-mediated dUTP nick-end labeling (TUNEL) were used to detect cell apoptosis and injury.

RESULTS: Compared with the CA group, the mean arterial pressure (MAP) in the EA group increased significantly at 15 minutes after ROSC [mmHg (1 mmHg ≈ 0.133 kPa): 125.00 (94.00, 136.25) vs. 92.00 (72.00, 122.50), P < 0.05]. There was no significant difference in the NDS score between the EA group and the sham group. Still, the NDS score of the rats in the CA group at 6 hours after ROSC were significantly lower than that in the sham group (46.00±10.61 vs. 80.00±0.00, P < 0.05). Kaplan-Meier survival curve analysis showed that EA did not improve the 72-hour survival rate of rats (100% in the sham group, 25% in the CA group, and 30% in the EA group, P > 0.05). The analysis by TUNEL showed that the apoptosis rate of neurons in CA1 region of the hippocampus in EA group at 6 hours after ROSC was significantly lower than that in CA group [(62.84±2.67)% vs. (71.29±3.70)%, P < 0.05]. Compared with the CA group, the level of serum S100 calcium binding protein B (S100B) in the EA group at 6 hours after ROSC was significantly lower (ng/L: 19.30±13.87 vs. 132.28±31.67, P < 0.05), but there were no significant differences in the levels of tumor necrosis factor-α (TNF-α) and interleukin-6 (IL-6) between these two groups.

CONCLUSIONS: In the present study, EA at Baihui can stabilize the hemodynamic, moreover, it has a particular neuroprotective effect on PCAS rats. Still, EA at Baihui does not reduce the systemic inflammatory response and improve the survival rate of rats, and its mechanism remains to be verified in further research.

来源:Zhonghua Wei Zhong Bing Ji Jiu Yi Xue,查看原文。版权归原作者所有。

参考来源

  1. Zeng R, Zhong Y, Wu Y, et al. [Effect of electroacupuncture at Baihui ameliorated neurologic deficit and hemodynamic stability in rat model of post-cardiac arrest syndrome]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2022. PMID: 36567584. doi:10.3760/cma.j.cn121430-20210115-00068

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。