电阻抗断层成像指导急性呼吸窘迫综合征合并慢性阻塞性肺疾病患者的呼气末正压滴定
本研究为单中心前瞻性重复测量研究,纳入2017年8月至2020年12月ICU收治的27例机械通气ARDS患者(合并COPD 14例,非COPD 13例),比较EIT与ARDSnet方案滴定的PEEP对呼吸力学、气体交换和血流动力学的影响。结果显示,COPD组EIT滴定PEEP为6.93±1.69 cm H2O,低于ARDSnet方案的10.43±1.20 cm H2O(P<0.001),同时整体不均一性指数、平台气道压、死腔通气比、通气比值和机械能均降低,心脏指数和氧输送升高。提示对ARDS合并COPD患者,EIT指导的PEEP滴定可能减少对血流动力学的不利影响。
要点
- ARDS合并COPD患者EIT滴定PEEP为6.93±1.69 cm H2O,低于非COPD组的12.15±2.40 cm H2O(P<0.001)。
- COPD组EIT滴定PEEP低于ARDSnet方案(6.93±1.69 vs. 10.43±1.20 cm H2O,P<0.001)。
- COPD组EIT滴定较ARDSnet方案降低整体不均一性指数(0.397±0.040 vs. 0.446±0.052,P=0.001)和平台气道压(16.50±4.35 vs. 20.93±5.37 cm H2O,P=0.001)。
- COPD组EIT滴定较ARDSnet方案降低死腔通气比(48.29±6.78% vs. 55.14±8.85%,P<0.001)、通气比值(1.63±0.33 vs. 1.87±0.33,P<0.001)和机械能(13.92±2.18 vs. 15.87±2.53 J/min,P<0.001)。
- COPD组EIT滴定较ARDSnet方案升高心脏指数(3.41±0.50 vs. 3.02±0.43 L/min/m2,P<0.001)和氧输送(466.40±71.08 vs. 411.10±69.71 mL/min/m2,P=0.001)。
适用人群与场景
- 2017年8月至2020年12月ICU收治的需机械通气的ARDS患者,共27例,其中合并COPD 14例,非COPD 13例。
- 研究为单中心、前瞻性、重复测量研究。
研究设计与关键结果
- 单中心前瞻性重复测量研究,纳入27例机械通气ARDS患者(COPD组14例,非COPD组13例),比较EIT与ARDSnet方案滴定的PEEP对呼吸力学、气体交换和血流动力学的影响。
- COPD组EIT滴定PEEP为6.93±1.69 cm H2O,低于非COPD组的12.15±2.40 cm H2O(P<0.001);COPD组ARDSnet方案PEEP为10.43±1.20 cm H2O,低于非COPD组的14.0±3.0 cm H2O(P<0.001)。
- COPD组中,EIT滴定PEEP低于ARDSnet方案(6.93±1.69 vs. 10.43±1.20 cm H2O,P<0.001),整体不均一性指数(0.397±0.040 vs. 0.446±0.052,P=0.001)、平台气道压(16.50±4.35 vs. 20.93±5.37 cm H2O,P=0.001)、死腔通气比(48.29±6.78% vs. 55.14±8.85%,P<0.001)、通气比值(1.63±0.33 vs. 1.87±0.33,P<0.001)和机械能(13.92±2.18 vs. 15.87±2.53 J/min,P<0.001)均降低。
- COPD组中,EIT滴定较ARDSnet方案升高心脏指数(3.41±0.50 vs. 3.02±0.43 L/min/m2,P<0.001)和氧输送(466.40±71.08 vs. 411.10±69.71 mL/min/m2,P=0.001)。
证据类型、等级与局限
- 证据类型:单中心前瞻性重复测量研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,在ARDS合并COPD患者中,应用EIT滴定PEEP较ARDSnet方案更低,有助于改善通气比值、机械能、心脏指数和氧输送,且对血流动力学的不利影响较小。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Chronic obstructive pulmonary disease (COPD) is one of most common comorbidities in acute respiratory distress syndrome (ARDS). There are few specific studies on the appropriate ventilation strategy for patients with ARDS comorbid with COPD, especially regarding on positive end-expiratory pressure (PEEP) titration.
METHODS: To compare the respiratory mechanics in mechanical ventilated ARDS patients with or without COPD and to determine whether titration of PEEP based on electrical impedance tomography (EIT) is superior to the ARDSnet protocol. This is a single center, perspective, repeated measure study. ARDS patients requiring mechanical ventilation who were admitted to the intensive care unit between August 2017 and December 2020 were included. ARDS patients were divided according to whether they had COPD into a COPD group and a non-COPD group. Respiratory mechanics, gas exchange, and hemodynamics during ventilation were compared between the groups according to whether the PEEP level was titrated by EIT or the ARDSnet protocol.
RESULTS: A total of twenty-seven ARDS patients including 14 comorbid with and 13 without COPD who met the study eligibility criteria were recruited. The PEEP levels titrated by EIT and the ARDSnet protocol were lower in the COPD group than in the non-COPD group (6.93 ± 1.69 cm H2O vs. 12.15 ± 2.40 cm H2O, P < 0.001 and 10.43 ± 1.20 cm H2O vs. 14.0 ± 3.0 cm H2O, P < 0.001, respectively). In the COPD group, the PEEP level titrated by EIT was lower than that titrated by the ARDSnet protocol (6.93 ± 1.69 cm H2O vs. 10.43 ± 1.20 cm H2O, P < 0.001), as was the global inhomogeneity (GI) index (0.397 ± 0.040 vs. 0.446 ± 0.052, P = 0.001), plateau airway pressure (16.50 ± 4.35 cm H2O vs. 20.93 ± 5.37 cm H2O, P = 0.001), dead space ventilation ratio (48.29 ± 6.78% vs. 55.14 ± 8.85%, P < 0.001), ventilation ratio (1.63 ± 0.33 vs. 1.87 ± 0.33, P < 0.001), and mechanical power (13.92 ± 2.18 J/min vs. 15.87 ± 2.53 J/min, P < 0.001). The cardiac index was higher when PEEP was treated by EIT than when it was titrated by the ARDSnet protocol (3.41 ± 0.50 L/min/m2 vs. 3.02 ± 0.43 L/min/m2, P < 0.001), as was oxygen delivery (466.40 ± 71.08 mL/min/m2 vs. 411.10 ± 69.71 mL/min/m2, P = 0.001).
CONCLUSION: Titrated PEEP levels were lower in patients with ARDS with COPD than in ARDS patients without COPD. In ARDS patient comorbid with COPD, application of PEEP titrated by EIT was lower than those titrated by the ARDSnet protocol, which contributed to improvements in the ventilation ratio, mechanical energy, cardiac index, and oxygen delivery with less of an adverse impact on hemodynamics.
参考来源
- Liu X, Liu X, Meng J, et al. Electrical impedance tomography for titration of positive end-expiratory pressure in acute respiratory distress syndrome patients with chronic obstructive pulmonary disease. Crit Care. 2022. PMID: 36333809. doi:10.1186/s13054-022-04201-y
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。