文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

在COVID-19 ARDS俯卧位患者中使用新型套囊压力控制与声门下分泌物引流系统

Use of an innovative cuff pressure control and subglottic secretions drainage system in COVID-19 ARDS patients undergoing pronation.
PubMed 文献 · Crit Care · 2022-11-04
一句话结论在15例COVID-19 ARDS俯卧位患者中,Anapnoguard系统有效控制套囊压力并引流声门下分泌物,口咽微误吸发生率55%,胃微误吸未检出,VAP发生率40%,与现有COVID-19文献相比未见VAP下降。

该概念验证研究在15例COVID-19急性呼吸窘迫综合征患者中使用Anapnoguard气管导管及其控制单元,系统提供声门下吸引、排气、冲洗并通过检测套囊漏气控制套囊压力。在连接系统后72小时内采集85份气管吸引物,检测α-淀粉酶和胃蛋白酶作为口咽和胃微误吸标志物。口咽微误吸发生47例次(55%),未检测到胃微误吸;俯卧位或仰卧位不影响气管分泌物中α-淀粉酶和胃蛋白酶浓度。VAP发生率为40%,与当前COVID-19文献数据相比未显示VAP发生率降低。作者认为该新技术在预防呼吸机相关性呼吸道感染方面的价值值得评估。

要点

  • 在15例COVID-19 ARDS患者中,Anapnoguard系统提供了有效的套囊压力控制和声门下分泌物引流。
  • 连接系统后72小时内85份气管吸引物中,口咽微误吸发生47例次(55%),胃微误吸未检出。
  • 俯卧位或仰卧位不影响气管分泌物中α-淀粉酶和胃蛋白酶浓度。
  • VAP发生率为40%,与当前COVID-19文献报告数据相比未显示VAP发生率降低。
  • 作者认为该新技术在预防呼吸机相关性呼吸道感染方面的价值值得评估。

适用人群与场景

  • 15例COVID-19急性呼吸窘迫综合征患者。

处置流程与药物剂量

  • 使用Anapnoguard气管导管及其控制单元,系统提供声门下吸引、排气、冲洗,并通过检测套囊漏气控制套囊压力。

研究设计与关键结果

  • 概念验证研究:15例COVID-19 ARDS患者使用Anapnoguard系统,连接后72小时内采集85份气管吸引物。
  • 口咽微误吸发生47例次(55%),胃微误吸未检出。
  • 患者体位(俯卧位或仰卧位)不影响气管分泌物中α-淀粉酶和胃蛋白酶浓度。
  • VAP发生率为40%,与当前COVID-19文献报告数据相比未显示VAP发生率降低。
  • Anapnoguard系统提供了有效的套囊压力控制和声门下分泌物引流。

证据类型、等级与局限

  • 证据类型:概念验证研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为该新技术在预防呼吸机相关性呼吸道感染方面的价值值得评估。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

We conducted a proof of concept study where Anapnoguard endotracheal tubes and its control unit were used in 15 patients with COVID-19 acute respiratory distress syndrome. Anapnoguard system provides suction, venting, rinsing of subglottic space and controls cuff pressure detecting air leakage through the cuff. Alpha-amylase and pepsin levels, as oropharyngeal and gastric microaspiration markers, were assessed from 85 tracheal aspirates in the first 72 h after connection to the system. Oropharyngeal microaspiration occurred in 47 cases (55%). Episodes of gastric microaspiration were not detected. Patient positioning, either prone or supine, did not affect alpha-amylase and pepsin concentration in tracheal secretions. Ventilator-associated pneumonia (VAP) rate was 40%. The use of the AG system provided effective cuff pressure control and subglottic secretions drainage. Despite this, no reduction in the incidence of VAP has been demonstrated, compared to data reported in the current COVID-19 literature. The value of this new technology is worth of being evaluated for the prevention of ventilator-associated respiratory tract infections.

来源:Crit Care,查看原文。版权归原作者所有。