文献速递呼吸衰竭与机械通气儿科与产科急症重症综合管理与镇静镇痛

新生儿呼吸衰竭体外膜氧合期间的通气策略:IV级新生儿重症监护病房的现行做法

Ventilation Strategies During Extracorporeal Membrane Oxygenation for Neonatal Respiratory Failure: Current Approaches Among Level IV Neonatal ICUs.
PubMed 文献 · Crit Care Explor · 2022-11-15
一句话结论IV级NICU新生儿呼吸ECMO多由新生儿科医生主导、按本院方案管理,以压力控制SIMV为主,参数设置差异大,HFV作主要模式者少。

该横断面电子调查向参与儿童医院新生儿联盟的IV级NICU新生儿ECMO中心发放40题问卷,共20家ECMO中心回复。65%以静脉-动脉ECMO为主,先天性膈疝者达90%;65%遵循方案化指南,80%由新生儿科医生主要负责呼吸机管理;主要通气模式为压力控制(90%),其中同步间歇指令通气(SIMV)占80%。常见设置为PIP 16-20 cm H2O(55%)、PEEP 9-10 cm H2O(40%)、吸气时间0.5秒(55%)、频率10-15次(60%)、Fio2 22-30%(65%);5%以高频通气(HFV)为主要模式。55%在ECMO期间以一定程度的肺复张为目标以避免完全肺不张;55%在ECMO期间停用吸入一氧化氮(iNO),60%在撤除ECMO试验时使用iNO;促进拔管的非呼吸机措施包括支气管镜(50%)、外源性肺表面活性物质(25%)和非吸入性肺血管扩张剂(50%)。作者认为未来研究应着眼于识别改善新生儿ECMO患者结局的呼吸管理实践。

要点

  • 20家IV级NICU ECMO中心中,80%由新生儿科医生主要负责ECMO期间的呼吸机管理,65%遵循方案化指南。
  • 主要通气模式为压力控制(90%),其中SIMV占80%;仅5%以高频通气(HFV)为主要模式。
  • 常见设置:PIP 16-20 cm H2O(55%)、PEEP 9-10 cm H2O(40%)、吸气时间0.5秒(55%)、频率10-15(60%)、Fio2 22-30%(65%)。
  • 55%在ECMO期间以一定程度的肺复张为目标以避免完全肺不张;55%在ECMO期间停用iNO,60%在撤除ECMO试验时使用iNO。
  • 常用撤机(拔管)呼吸机阈值:PEEP 6-7(45%)、PIP 21-25(55%)、潮气量5-5.9 mL/kg(50%)。

适用人群与场景

  • 在IV级NICU因呼吸衰竭接受ECMO的新生儿;调查对象为参与儿童医院新生儿联盟的区域转诊新生儿ECMO中心的站点负责人。

处置流程与药物剂量

  • 多数中心(65%)遵循方案化指南进行ECMO期间呼吸机管理,80%由新生儿科医生主要负责;主要模式为压力控制(90%),其中SIMV占80%。
  • 常见设置:PIP 16-20 cm H2O(55%)、PEEP 9-10 cm H2O(40%)、吸气时间0.5秒(55%)、频率10-15(60%)、Fio2 22-30%(65%)。
  • 55%的中心在ECMO期间以一定程度的肺复张为目标以避免完全肺不张;5%以高频通气(HFV)为主要模式。
  • 55%的中心在ECMO期间停用iNO,60%在撤除ECMO试验时使用iNO。
  • 促进拔管的非呼吸机措施包括支气管镜(50%)、外源性肺表面活性物质(25%)和非吸入性肺血管扩张剂(50%)。
  • 常用撤机(拔管)呼吸机阈值:PEEP 6-7(45%)、PIP 21-25(55%)、潮气量5-5.9 mL/kg(50%)。

研究设计与关键结果

  • 研究类型为横断面电子调查(基于电子邮件的Research Electronic Data Capture调查),向参与儿童医院新生儿联盟的区域转诊新生儿ECMO中心站点负责人发放40题问卷,并在2周和4周时发送提醒邮件,共20家ECMO中心回复。
  • 65%的中心以静脉-动脉ECMO为主,先天性膈疝者该比例更高(90%)。
  • 主要通气模式为压力控制(90%),其中SIMV占80%;5%以高频通气(HFV)为主要模式。
  • 常见设置:PIP 16-20 cm H2O(55%)、PEEP 9-10 cm H2O(40%)、吸气时间0.5秒(55%)、频率10-15(60%)、Fio2 22-30%(65%)。
  • 55%的中心在ECMO期间以一定程度的肺复张为目标以避免完全肺不张;55%在ECMO期间停用iNO,60%在撤除ECMO试验时使用iNO。
  • 促进拔管的非呼吸机措施:支气管镜(50%)、外源性肺表面活性物质(25%)、非吸入性肺血管扩张剂(50%)。
  • 常用撤机(拔管)呼吸机阈值:PEEP 6-7(45%)、PIP 21-25(55%)、潮气量5-5.9 mL/kg(50%)。

证据类型、等级与局限

  • 证据类型:横断面电子调查;样本为20家参与儿童医院新生儿联盟的IV级NICU ECMO中心。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 调查显示多数IV级NICU在新生儿呼吸ECMO期间遵循本院方案、由新生儿科医生主导呼吸机管理,以压力控制SIMV为主,但参数设置范围差异大,仅少数中心以HFV为主要模式。
  • 作者认为未来研究应着眼于识别改善新生儿ECMO患者结局的呼吸管理实践。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

UNLABELLED: To describe ventilation strategies used during extracorporeal membrane oxygenation (ECMO) for neonatal respiratory failure among level IV neonatal ICUs (NICUs).

DESIGN: Cross-sectional electronic survey.

SETTING: Email-based Research Electronic Data Capture survey.

PATIENTS: Neonates undergoing ECMO for respiratory failure at level IV NICUs.

INTERVENTIONS: A 40-question survey was sent to site sponsors of regional referral neonatal ECMO centers participating in the Children's Hospitals Neonatal Consortium. Reminder emails were sent at 2- and 4-week intervals.

MEASUREMENTS AND MAIN RESULTS: Twenty ECMO centers responded to the survey. Most primarily use venoarterial ECMO (65%); this percentage is higher (90%) for congenital diaphragmatic hernia. Sixty-five percent reported following protocol-based guidelines, with neonatologists primarily responsible for ventilator management (80%). The primary mode of ventilation was pressure control (90%), with synchronized intermittent mechanical ventilation (SIMV) comprising 80%. Common settings included peak inspiratory pressure (PIP) of 16-20 cm H2O (55%), positive end-expiratory pressure (PEEP) of 9-10 cm H2O (40%), I-time 0.5 seconds (55%), rate of 10-15 (60%), and Fio2 22-30% (65%). A minority of sites use high-frequency ventilation (HFV) as the primary mode (5%). During ECMO, 55% of sites target some degree of lung aeration to avoid complete atelectasis. Fifty-five percent discontinue inhaled nitric oxide (iNO) during ECMO, while 60% use iNO when trialing off ECMO. Nonventilator practices to facilitate decannulation include bronchoscopy (50%), exogenous surfactant (25%), and noninhaled pulmonary vasodilators (50%). Common ventilator thresholds for decannulation include PEEP of 6-7 (45%), PIP of 21-25 (55%), and tidal volume 5-5.9 mL/kg (50%).

CONCLUSIONS: The majority of level IV NICUs follow internal protocols for ventilator management during neonatal respiratory ECMO, and neonatologists primarily direct management in the NICU. While most centers use pressure-controlled SIMV, there is considerable variability in the range of settings used, with few centers using HFV primarily. Future studies should focus on identifying respiratory management practices that improve outcomes for neonatal ECMO patients.

来源:Crit Care Explor,查看原文。版权归原作者所有。

参考来源

  1. Ibrahim J, Mahmood B, DiGeronimo R, et al. Ventilation Strategies During Extracorporeal Membrane Oxygenation for Neonatal Respiratory Failure: Current Approaches Among Level IV Neonatal ICUs. Crit Care Explor. 2022. PMID: 36406885. doi:10.1097/CCE.0000000000000779

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。