文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

急性呼吸窘迫综合征与气泡试验检测分流:系统评价与Meta分析

Acute Respiratory Distress Syndrome and Shunt Detection With Bubble Studies: A Systematic Review and Meta-Analysis.
PubMed 文献 · Crit Care Explor · 2022-11-07
一句话结论ARDS患者中超声气泡试验检出右向左分流者占21.8%,分流可能增加死亡风险(RR 1.22),但与氧合无显著差异。

该系统评价于2021年3月26日检索MEDLINE、EMBASE、Cochrane Library及DARE数据库,从4617条引文中纳入10项观察性研究。采用经胸、经食管及经颅气泡多普勒超声检测右向左分流,纳入研究中分流检出率为21.8%(范围14.4-30.0%)。分流可能增加死亡率(RR 1.22;95%CI 1.01-1.49;p=0.04,证据确定性极低),而PaO2:FiO2比值无差异(均数差-0.7;95%CI -18.6至17.2;p=0.94,证据确定性极低)。

要点

  • ARDS患者中经胸、经食管或经颅气泡多普勒超声检出右向左分流者为21.8%(范围14.4-30.0%)。
  • 分流与死亡率升高可能相关:RR 1.22(95%CI 1.01-1.49;p=0.04),证据确定性极低。
  • 分流与PaO2:FiO2比值无显著差异:均数差-0.7(95%CI -18.6至17.2;p=0.94),证据确定性极低。
  • 分流与氧合的关系不确定。

适用人群与场景

  • 纳入10项观察性研究,对象为ARDS患者,涉及呼吸衰竭与超声分流检测。

研究设计与关键结果

  • 研究类型:系统评价与Meta分析;从4617条引文中纳入10项观察性研究。
  • 分流检出率:经胸、经食管及经颅气泡多普勒超声检测右向左分流存在于21.8%的患者(范围14.4-30.0%)。
  • 死亡率:分流可能增加死亡率(RR 1.22;95%CI 1.01-1.49;p=0.04,证据确定性极低)。
  • 氧合:PaO2:FiO2比值无差异(均数差-0.7;95%CI -18.6至17.2;p=0.94,证据确定性极低)。

证据类型、等级与局限

  • 证据类型:系统评价与Meta分析,纳入10项观察性研究;采用Joanna-Briggs Institute和Newcastle-Ottawa Scale工具评估偏倚风险,并使用GRADE方法评定证据确定性。
  • 死亡率结局证据确定性极低;氧合结局证据确定性极低。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 超声气泡试验在ARDS患者中可频繁检出肺内和肺外分流(21.8%)。
  • 分流可能增加ARDS患者死亡率,但与氧合的关系不确定。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

UNLABELLED: Acute respiratory distress syndrome (ARDS) is a life-threatening respiratory injury with multiple physiological sequelae. Shunting of deoxygenated blood through intra- and extrapulmonary shunts may complicate ARDS management. Therefore, we conducted a systematic review to determine the prevalence of sonographically detected shunts, and their association with oxygenation and mortality in patients with ARDS.

DATA SOURCES: Medical literature analysis and retrieval system online, Excerpta Medica dataBASE, Cochrane Library, and database of abstracts of reviews of effects databases on March 26, 2021.

STUDY SELECTION: Articles relating to respiratory failure and sonographic shunt detection.

DATA EXTRACTION: Articles were independently screened and extracted in duplicate. Data pertaining to study demographics and shunt detection were compiled for mortality and oxygenation outcomes. Risk of bias was appraised using the Joanna-Briggs Institute and the Newcastle-Ottawa Scale tools with evidence rating certainty using Grading of Recommendations Assessment, Development and Evaluation methodology.

DATA SYNTHESIS: From 4,617 citations, 10 observational studies met eligibility criteria. Sonographic detection of right-to-left shunt was present in 21.8% of patients (range, 14.4-30.0%) among included studies using transthoracic, transesophageal, and transcranial bubble Doppler ultrasonographies. Shunt prevalence may be associated with increased mortality (risk ratio, 1.22; 95% CI, 1.01-1.49; p = 0.04, very low certainty evidence) with no difference in oxygenation as measured by Pao2:Fio2 ratio (mean difference, -0.7; 95% CI, -18.6 to 17.2; p = 0.94, very low certainty).

CONCLUSIONS: Intra- and extrapulmonary shunts are detected frequently in ARDS with ultrasound techniques. Shunts may increase mortality among patients with ARDS, but its association with oxygenation is uncertain.

来源:Crit Care Explor,查看原文。版权归原作者所有。

参考来源

  1. Odenbach J, Dhanoa S, Sebastianski M, et al. Acute Respiratory Distress Syndrome and Shunt Detection With Bubble Studies: A Systematic Review and Meta-Analysis. Crit Care Explor. 2022. PMID: 36382336. doi:10.1097/CCE.0000000000000789

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。