机械通气质量改进项目对非目标人群的溢出效应
在学术医疗中心开展前后实施中断时间序列分析,评估针对冠脉搭桥(CABG)手术患者的术后机械通气质量改进项目对未被纳入方案的左心瓣膜手术患者的影响。CABG患者机械通气时间中位数从P0期11小时降至P2期6.22小时(p<0.001);被排除的瓣膜患者也从P0期10小时降至P2期6小时(p<0.001)。中断时间序列分析显示两组P0至P2期通气时间水平变化均显著(均p<0.0001),两组变化斜率无显著差异。结论提示质量改进的获益可超出目标人群。
要点
- CABG患者机械通气时间中位数由P0期11小时降至P2期6.22小时(p<0.001)。
- 未纳入方案的瓣膜手术患者机械通气时间由P0期10小时降至P2期6小时(p<0.001),存在溢出效应。
- 中断时间序列分析示P0至P2期通气时间水平变化:CABG患者p<0.0001,瓣膜患者p<0.0001。
- 两组变化斜率无显著差异:P0 vs P1 p=0.8809,P1 vs P2 p=0.3834,P0 vs P2 p=0.7672。
- 质量改进项目的获益可能超出预设目标人群,惠及未被纳入方案的患者。
适用人群与场景
- 接受冠脉搭桥(CABG)手术的患者(纳入干预)。
- 接受左心瓣膜手术的患者(被排除于干预方案之外)。
处置流程与药物剂量
- 针对CABG患者制定术后机械通气质量改进方案;原文未报告具体通气策略、撤机流程或药物剂量。
研究设计与关键结果
- 研究类型为前后实施中断时间序列分析,在学术医疗中心开展,分析CABG手术患者(纳入)与左心瓣膜手术患者(排除)在干预前、中、后的机械通气时间变化。
- CABG患者机械通气时间中位数:P0(「之前」阶段)11小时 vs P2(「之后」阶段)6.22小时(p<0.001)。
- 被排除于方案的瓣膜患者机械通气时间中位数:P0期10小时 vs P2期6小时(p<0.001),观察到溢出效应。
- 中断时间序列分析显示P0至P2期通气时间水平变化:CABG患者p<0.0001,瓣膜患者p<0.0001。
- CABG与瓣膜患者随时间队列的变化斜率无显著差异:P0 vs P1 p=0.8809;P1 vs P2 p=0.3834;P0 vs P2 p=0.7672,提示纳入与排除患者机械通气时间的变化速率相似。
证据类型、等级与局限
- 证据类型:前后实施中断时间序列分析(质量改进项目评估)。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,未纳入方案的患者机械通气时间下降提示质量改进存在溢出效应,质量改进可惠及目标人群之外的患者。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
UNLABELLED: To assess the impact of a mechanical ventilation quality improvement program on patients who were excluded from the intervention.
DESIGN: Before-during-and-after implementation interrupted time series analysis to assess the effect of the intervention between coronary artery bypass grafting (CABG) surgery patients (included) and left-sided valve surgery patients (excluded).
SETTING: Academic medical center.
PATIENTS: Patients undergoing CABG and left-sided valve procedures were analyzed.
INTERVENTIONS: A postoperative mechanical ventilation quality improvement program was developed for patients undergoing CABG.
MEASUREMENTS AND MAIN RESULTS: Patients undergoing CABG had a median mechanical ventilation time of 11 hours during P0 ("before" phase) and 6.22 hours during P2 ("after" phase; p < 0.001). A spillover effect was observed because mechanical ventilation times also decreased from 10 hours during P0 to 6 hours during P2 among valve patients who were excluded from the protocol (p < 0.001). The interrupted time series analysis demonstrated a significant level of change for ventilation time from P0 to P2 for both CABG (p < 0.0001) and valve patients (p < 0.0001). There was no significant difference in the slope of change between the CABG and valve patient populations across time cohorts (P0 vs P1 [p = 0.8809]; P1 vs P2 [p = 0.3834]; P0 vs P2 [p = 0.7672]), which suggests that the rate of change in mechanical ventilation times was similar between included and excluded patients.
CONCLUSIONS: Decreased mechanical ventilation times for patients who were not included in a protocol suggests a spillover effect of quality improvement and demonstrates that quality improvement can have benefits beyond a target population.
参考来源
- Greenwald AS, Hauw-Berlemont C, Shan M, et al. The Spillover Effects of Quality Improvement Beyond Target Populations in Mechanical Ventilation. Crit Care Explor. 2022. PMID: 36419635. doi:10.1097/CCE.0000000000000802
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。