文献速递心脑血管急症重症综合管理与镇静镇痛

脉压/中心静脉压比值对心脏术后低心排综合征的临床价值

[Clinical value of pulse pressure/central venous pressure ratio in low cardiac output syndrome after cardiac surgery].
PubMed 文献 · Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · 2022-01-01
一句话结论心脏术后6小时PP/CVP比值≤4.41对低心排综合征有良好预测价值(AUC 0.94,敏感度80.00%,特异度96.00%)。

该回顾性研究纳入2016年1月1日至2021年9月1日在北京协和医院重症医学科接受PiCCO监测的心脏术后患者150例,按术后6小时CI分为低心排综合征组(CI<33.34 mL×s-1×m-2,25例)与非低心排综合征组(CI≥33.34 mL×s-1×m-2,125例)。低心排综合征组脉压更低、中心静脉压更高、脉压/中心静脉压比值更低(3.3 vs 5.5)。脉压/中心静脉压比值与CI、CO、SVI呈正相关,ROC分析显示其预测低心排综合征的AUC为0.94±0.02,最佳截断值4.41时敏感度80.00%、特异度96.00%。作者认为脉压/中心静脉压比值可作为心脏术后低心排综合征的预后预测指标。

要点

  • 心脏术后6小时CI<33.34 mL×s-1×m-2定义为低心排综合征,本研究150例中25例发生。
  • 低心排综合征组脉压40(37,44)mmHg低于非低心排综合征组55(46,64)mmHg,中心静脉压12(11,14)mmHg高于非低心排综合征组10(8,12)mmHg(均P<0.05)。
  • 低心排综合征组脉压/中心静脉压比值3.3(2.9,3.7)低于非低心排综合征组5.5(4.6,6.8),差异有统计学意义(P<0.05)。
  • 脉压/中心静脉压比值与CI、CO、SVI呈正相关(rs=0.660、0.592、0.600,均P<0.001)。
  • 脉压/中心静脉压比值预测低心排综合征的AUC为0.94±0.02(P<0.001),最佳截断值4.41,敏感度80.00%,特异度96.00%。

适用人群与场景

  • 2016年1月1日至2021年9月1日在北京协和医院重症医学科接受PiCCO监测的心脏术后患者150例。
  • 按术后6小时CI分为低心排综合征组(CI<33.34 mL×s-1×m-2,25例)与非低心排综合征组(CI≥33.34 mL×s-1×m-2,125例)。

诊断标准与关键阈值

  • 低心排综合征诊断标准:术后6小时CI<33.34 mL×s-1×m-2。
  • 脉压/中心静脉压比值预测低心排综合征的最佳截断值为4.41。

研究设计与关键结果

  • 回顾性研究纳入150例心脏术后PiCCO监测患者,低心排综合征组25例,非低心排综合征组125例,两组基线特征无差异。
  • 低心排综合征组脉压40(37,44)mmHg低于非低心排综合征组55(46,64)mmHg,中心静脉压12(11,14)mmHg高于非低心排综合征组10(8,12)mmHg,脉压/中心静脉压比值3.3(2.9,3.7)低于非低心排综合征组5.5(4.6,6.8),差异均有统计学意义(均P<0.05)。
  • 脉压/中心静脉压比值与CI、CO、SVI呈正相关(rs=0.660、0.592、0.600,均P<0.001);CI与脉压呈负相关(rs=0.509,P<0.001),与中心静脉压呈正相关(rs=-0.297,P<0.001)。
  • ROC曲线分析显示,与脉压、中心静脉压、SVI、心脏功能指数相比,脉压/中心静脉压比值是心脏术后低心排综合征的最佳预测指标(AUC=0.94±0.02,P<0.001),最佳截断值4.41时敏感度80.00%,特异度96.00%。

证据类型、等级与局限

  • 证据类型:回顾性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为脉压/中心静脉压比值与心脏术后CO呈中度正相关,可作为心脏术后低心排综合征的预后预测指标。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To explore the relationship between the pulse pressure/central venous pressure (PP/CVP) ratio and the cardiac output (CO) of patients after cardiac surgery from the basic principles of hemodynamics, and to further evaluate the predictive value of PP/CVP ratio in patients with secondary low cardiac output syndrome (LCOS) after cardiac surgery.

METHODS: A retrospective study was conducted, and patients who received pulse indicator continuous cardiac output (PiCCO) monitoring were enrolled at the department of critical care medicine of Peking Union Medical College Hospital from January 1, 2016, to September 1, 2021. Patients were divided into two groups: the LCOS group [cardiac index (CI) < 33.34 mL×s-1×m-2, 25 cases] and the non-LCOS group (CI ≥ 33.34 mL×s-1×m-2, 125 cases) according to the CI at 6 hours after surgery. The general clinical data and hemodynamic parameters were collected. Correlations between PP/CVP ratio and PiCCO monitoring indicators were performed with Pearson or Spearman correlation test. Receiver operator characteristic curve (ROC curve) analysis was carried out to evaluate the predictive value of the parameters in patients with LCOS after cardiac surgery.

RESULTS: A total of 150 patients with PiCCO monitoring after cardiac surgery were included. There were no differences in baseline characteristics between the two groups, while PP in the LCOS group was lower than that in the non-LCOS group [mmHg (1 mmHg ≈ 0.133 kPa): 40 (37, 44) vs. 55 (46, 64)], CVP was higher than that in the non-LCOS group [mmHg: 12 (11, 14) vs. 10 (8, 12)], and PP/CVP ratio in the LCOS group was lower than that in the non-LCOS group [3.3 (2.9, 3.7) vs. 5.5 (4.6, 6.8)], with significant differences (all P < 0.05). Correlation analysis results showed that PP/CVP ratio was positively correlated with CI, CO, and stroke volume index (SVI), respectively (rs = 0.660, 0.592, 0.600, all P < 0.001). CI was negatively correlated with PP (rs = 0.509, P < 0.001) and positively correlated with CVP (rs = -0.297, P < 0.001). ROC curve analysis revealed that compared with PP, CVP, SVI and cardiac function index (CFI), PP/CVP ratio was the best predictor of LCOS after cardiac surgery [area under the ROC curve (AUC) was 0.94±0.02, P < 0.001], when the optimum cut-off value was 4.41, the sensitivity was 80.00%, and the specificity was 96.00%.

CONCLUSIONS: PP/CVP ratio was moderately positively correlated with CO after cardiac surgery, and PP/CVP ratio could be used as a prognostic predictor for LCOS after cardiac surgery.

来源:Zhonghua Wei Zhong Bing Ji Jiu Yi Xue,查看原文。版权归原作者所有。

参考来源

  1. Zhou G, Liu J, Zhang H, et al. [Clinical value of pulse pressure/central venous pressure ratio in low cardiac output syndrome after cardiac surgery]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2022. PMID: 36177921. doi:10.3760/cma.j.cn121430-20220621-00596

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。