重症患者右心室应变测量:一项观察性SICS子研究
本研究为单中心前瞻性观察队列(SICS-I和SICS-II)子研究,纳入171例急性入ICU且预计停留超过24小时的成人患者,入ICU 24小时内行重症超声心动图。右心室游离壁纵向应变(RVFWSL)和右心室整体四腔纵向应变(RV4CSL)的可行率分别为62%和56%,测量成功时组内与组间信度基于组内相关系数为好至极好。基于TAPSE或RV s'诊断右心室功能障碍者56例(33%),基于RVFWSL或RV4CSL诊断者24例(14%),14例(8%)常规右心室功能测量保留但应变减低,这些患者疾病严重度评分显著更高。作者认为组织多普勒右心室应变成像在重症患者中具有挑战性,未来需研究其诊断和预后价值。
要点
- 在171例急性入ICU的成人中,RVFWSL和RV4CSL的可行率分别为62%和56%。
- 测量成功时,RVFWSL和RV4CSL的组内与组间信度基于组内相关系数为好至极好。
- 基于TAPSE或RV s'诊断右心室功能障碍者56例(33%),基于RVFWSL或RV4CSL诊断者24例(14%)。
- 14例(8%)患者常规右心室功能测量保留但RVFWSL、RV4CSL或两者减低,这些患者疾病严重度评分显著更高。
- 作者认为组织多普勒右心室应变成像在重症患者中具有挑战性,未来需研究其诊断和预后价值。
适用人群与场景
- 急性入院的成人患者,预计ICU停留时间超过24小时。
研究设计与关键结果
- 研究类型:单中心、两项前瞻性观察队列(SICS-I和SICS-II)的子研究;样本量171例;人群为急性入ICU的成人患者,预计ICU停留超过24小时;干预:入ICU 24小时内行重症超声心动图,获取TAPSE、三尖瓣环收缩期峰值速度(RV s')和组织多普勒图像,离线分析测量RVFWSL和RV4CSL;对照:无。
- 可行性:RVFWSL为62%,RV4CSL为56%;测量成功时,基于组内相关系数的组内与组间信度为好至极好。
- 右心室功能障碍:基于TAPSE或RV s'诊断56例(33%),基于RVFWSL或RV4CSL诊断24例(14%)。
- 14例(8%)患者RVFWSL、RV4CSL或两者减低,而常规右心室功能测量保留,这些患者疾病严重度评分显著更高。
- 采用面积变化分数进行的敏感性分析显示类似结果。
证据类型、等级与局限
- 证据类型:观察性研究(前瞻性队列子研究)。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为组织多普勒右心室应变成像在重症患者中具有挑战性,但测量成功时重复性好;未来需研究其诊断和预后价值,尤其需权衡成像难度与临床价值。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Right ventricular (RV) dysfunction is common in critically ill patients and is associated with poor outcomes. RV function is usually evaluated by Tricuspid Annular Plane Systolic Excursion (TAPSE) which can be obtained using critical care echocardiography (CCE). Myocardial deformation imaging, measuring strain, is suitable for advanced RV function assessment and has widely been studied in cardiology. However, it is relatively new for the Intensive Care Unit (ICU) and little is known about RV strain in critically ill patients. Therefore, the objectives of this study were to evaluate the feasibility of RV strain in critically ill patients using tissue-Doppler imaging (TDI) and explore the association between RV strain and conventional CCE measurements representing RV function.
METHODS: This is a single-center sub-study of two prospective observational cohorts (Simple Intensive Care Studies (SICS)-I and SICS-II). All acutely admitted adults with an expected ICU stay over 24 h were included. CCE was performed within 24 h of ICU admission. In patients in which CCE was performed, TAPSE, peak systolic velocity at the tricuspid annulus (RV s') and TDI images were obtained. RV free wall longitudinal strain (RVFWSL) and RV global four-chamber longitudinal strain (RV4CSL) were measured during offline analysis.
RESULTS: A total of 171 patients were included. Feasibility of RVFWSL and RV4CSL was, respectively, 62% and 56% in our population; however, when measurements were performed, intra- and inter-rater reliability based on the intraclass correlation coefficient were good to excellent. RV dysfunction based on TAPSE or RV s' was found in 56 patients (33%) and 24 patients (14%) had RV dysfunction based on RVFWSL or RV4CSL. In 14 patients (8%), RVFWSL, RV4CSL, or both were reduced, despite conventional RV function measurements being preserved. These patients had significantly higher severity of illness scores. Sensitivity analysis with fractional area change showed similar results.
CONCLUSIONS: TDI RV strain imaging in critically ill patients is challenging; however, good-to-excellent reproducibility was shown when measurements were adequately obtained. Future studies are needed to elucidate the diagnostic and prognostic value of RV strain in critically ill patients, especially to outweigh the difficulty and effort of imaging against the clinical value.
参考来源
- Vos ME, Cox EGM, Schagen MR, et al. Right ventricular strain measurements in critically ill patients: an observational SICS sub-study. Ann Intensive Care. 2022. PMID: 36190597. doi:10.1186/s13613-022-01064-y
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。