文献速递创伤与烧伤

「一站式」窗宽窗位全身CT扫描——更快评估创伤病例的方法

"All-in-one" window/level whole-body computed tomography scan - A faster way to evaluate trauma cases.
PubMed 文献 · Am J Emerg Med · 2022-10-07
一句话结论在限时阅片下,一站式窗宽窗位与常规多窗设置诊断准确性相似,但总评估时间快14.3秒,可能有助于加快创伤患者处理。

该研究回顾性选取50例因严重创伤到急诊科就诊患者的增强胸、腹、盆腔CT,模拟在CT操作台进行「湿读」,6名不同经验水平的阅片者每例最多3分钟描述创伤发现。每例分别使用一站式窗宽窗位与常规骨、肺、软组织窗宽窗位设置(随机顺序、洗脱期)阅片,以CT报告为参考标准。结果显示两种设置评估准确性无统计学显著差异(0.89 ± 0.09 vs 0.90 ± 0.08),一站式设置总评估时间快14.3秒(2.33 ± 0.63 vs 2.57 ± 0.51分钟;p < 0.001)。作者认为在CT操作台进行湿读时,使用单一AI O窗宽窗位识别创伤可能有助于加快患者管理。

要点

  • 在限时(每例最多3分钟)阅片下,一站式窗宽窗位与常规多窗设置的评估准确性无统计学显著差异(0.89 ± 0.09 vs 0.90 ± 0.08)。
  • 使用一站式窗宽窗位时总评估时间较常规设置快14.3秒(2.33 ± 0.63 vs 2.57 ± 0.51分钟;p < 0.001)。
  • 研究为回顾性选取50例严重创伤患者的增强胸、腹、盆腔CT,6名不同经验阅片者参与。
  • 作者认为在CT操作台进行湿读时,单一AI O窗宽窗位可能有助于加快创伤患者管理。

适用人群与场景

  • 因严重创伤到急诊科就诊、接受增强胸部、腹部和盆腔CT扫描的患者(回顾性选取50例)。

研究设计与关键结果

  • 研究类型:回顾性研究,模拟在CT操作台进行「湿读」;样本量50例患者;6名不同经验水平的阅片者。
  • 干预与对照:每例CT分别使用一站式窗宽窗位设置与常规骨、肺、软组织窗宽窗位设置阅片,随机顺序,两次阅片间设洗脱期以抑制回忆偏倚;以CT报告为参考标准。
  • 主要终点:两种设置评估准确性无统计学显著差异(0.89 ± 0.09 vs 0.90 ± 0.08)。
  • 总评估时间:一站式窗宽窗位设置较常规设置快14.3秒(2.33 ± 0.63 vs 2.57 ± 0.51分钟;p < 0.001)。

证据类型、等级与局限

  • 证据类型:回顾性研究(模拟湿读)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,在CT操作台提供湿读时,使用单一「一站式」窗宽窗位识别创伤可能有助于加快患者管理。
  • 在限时阅片条件下,一站式窗宽窗位与常规多窗设置的诊断准确性相似,但总评估时间更短。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

PURPOSE: To investigate the accuracy and total assessment time (TAT) of the "All-in-one" (AIO)-window/level setting for whole-body computed tomography (CT) image compared to multiple tissue-specific window/level settings conventionally used for detection of traumatic injuries.

METHOD: Contrast-enhanced chest, abdomen, and pelvic CT scans of 50 patients who presented to our emergency department (ED) for major trauma were retrospectively selected. In a simulation of a "wet read" performed at the CT scanner console, 6 readers with different levels of experience had up to 3 min to describe any traumatic finding identified on the CTs. The readers reviewed each patient in two different sessions separated by a washout period to suppress any recall bias from one session to the next. Each scan was reviewed once using the AIO-window/level setting and another time using the conventional bone, lung, and soft tissue window/level display settings, in a randomized order. The CT reports were used as reference standard.

RESULTS: Overall, there was no statistically significant difference in the assessment accuracy of the review based on the AIO or the conventional window/level settings (0.89 ± 0.09 vs 0.90 ± 0.08). Using the AIO-window/level settings, TAT was 14.3 s faster when compared with the conventional window/level settings (2.33 ± 0.63 vs 2.57 ± 0.51 min; p < 0.001).

CONCLUSIONS: In a time-delimited image review, similar diagnostic accuracy was reached faster using the AIO vs the conventional window/level settings. When providing a "wet read" at the CT console, the ability to identify traumatic injury using a single AIO-window/level may help expedite patient management.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Figueiro Longo MG, Vuylsteke P, Tan CO, et al. "All-in-one" window/level whole-body computed tomography scan - A faster way to evaluate trauma cases. Am J Emerg Med. 2022. PMID: 36272188. doi:10.1016/j.ajem.2022.09.047