文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

通过杨氏模量将驱动压滴定至肺弹性实现个体化机械通气:急性呼吸窘迫综合征动物模型研究

Individualizing mechanical ventilation: titration of driving pressure to pulmonary elastance through Young's modulus in an acute respiratory distress syndrome animal model.
PubMed 文献 · Crit Care · 2022-10-18
一句话结论在ARDS大鼠模型中,按杨氏模量个体化滴定驱动压较标准保护性通气降低肺炎症与结构损伤,对氧合无显著影响。

研究使用20只雄性Wistar Han大鼠建立急性呼吸窘迫综合征模型,随机分为标准保护性机械通气组(驱动压=14 cm H2O,潮气量<6 mL/kg,通气150分钟)和个体化机械通气组(根据杨氏模量个体化驱动压,通气150分钟),两组均以相同方式设置个体化呼气末正压。结果显示个体化组整体驱动压更低(14 vs 11 cm H2O,p=0.03),支气管肺泡灌洗液中IL-6(270 pg/mL vs 155 pg/mL,p=0.02)、TNF-α(292 pg/mL vs 139 pg/mL,p<0.01)、IL-1β(563 pg/mL vs 131 pg/mL,p=0.05)浓度更低,淋巴细胞比例更低(96% vs 79%,p=0.05),肺损伤评分更低(6.0分 vs 2.0分,p=0.02),而氧合无显著影响。作者认为通过杨氏模量将驱动压个体化至肺弹性可减少肺炎症和结构性肺损伤。

要点

  • 在ARDS大鼠模型中,按杨氏模量个体化驱动压使整体驱动压低于标准保护性通气(14 vs 11 cm H2O,p=0.03)。
  • 个体化驱动压组支气管肺泡灌洗液IL-6(270 pg/mL vs 155 pg/mL,p=0.02)、TNF-α(292 pg/mL vs 139 pg/mL,p<0.01)、IL-1β(563 pg/mL vs 131 pg/mL,p=0.05)浓度均低于标准组。
  • 个体化驱动压组淋巴细胞比例更低(96% vs 79%,p=0.05),肺损伤评分更低(6.0分 vs 2.0分,p=0.02)。
  • 个体化驱动压对氧合无显著影响。

适用人群与场景

  • 20只雄性Wistar Han大鼠,建立急性呼吸窘迫综合征模型后纳入研究。

处置流程与药物剂量

  • 标准保护性机械通气组(10只):驱动压=14 cm H2O,潮气量<6 mL/kg,通气150分钟。
  • 个体化机械通气组(10只):根据杨氏模量设定个体化驱动压,通气150分钟。
  • 两组均以相同方式设置个体化呼气末正压。

研究设计与关键结果

  • 研究类型:急性呼吸窘迫综合征动物模型研究,20只雄性Wistar Han大鼠。
  • 干预与对照:标准保护性机械通气(驱动压=14 cm H2O,潮气量<6 mL/kg,150分钟)vs 根据杨氏模量个体化驱动压(150分钟),两组均设置个体化呼气末正压。
  • 整体驱动压:个体化组 vs 标准组为11 cm H2O vs 14 cm H2O(p=0.03)。
  • 支气管肺泡灌洗液IL-6:个体化组 vs 标准组为155 pg/mL vs 270 pg/mL(p=0.02)。
  • 支气管肺泡灌洗液TNF-α:个体化组 vs 标准组为139 pg/mL vs 292 pg/mL(p<0.01)。
  • 支气管肺泡灌洗液IL-1β:个体化组 vs 标准组为131 pg/mL vs 563 pg/mL(p=0.05)。
  • 淋巴细胞比例:个体化组 vs 标准组为79% vs 96%(p=0.05)。
  • 肺损伤评分:个体化组 vs 标准组为2.0分 vs 6.0分(p=0.02)。

证据类型、等级与局限

  • 证据类型:急性呼吸窘迫综合征动物模型研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 在急性呼吸窘迫综合征动物模型中,通过杨氏模量将驱动压个体化至肺弹性可降低肺炎症和结构肺损伤且对氧合无显著影响,作者认为该策略可减少呼吸机相关性肺损伤。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Mechanical ventilation increases the risk of lung injury (VILI). Some authors propose that the way to reduce VILI is to find the threshold of driving pressure below which VILI is minimized. In this study, we propose a method to titrate the driving pressure to pulmonary elastance in an acute respiratory distress syndrome model using Young's modulus and its consequences on ventilatory-induced lung injury.

MATERIAL AND METHODS: 20 Wistar Han male rats were used. After generating an acute respiratory distress syndrome, two groups were studied: (a) standard protective mechanical ventilation: 10 rats received 150 min of mechanical ventilation with driving pressure = 14 cm H2O, tidal volume < 6 mL/kg) and (b) individualized mechanical ventilation: 10 rats received 150 min of mechanical ventilation with an individualized driving pressure according to their Young's modulus. In both groups, an individualized PEEP was programmed in the same manner. We analyzed the concentration of IL-6, TNF-α, and IL-1ß in BAL and the acute lung injury score in lung tissue postmortem.

RESULTS: Global driving pressure was different between the groups (14 vs 11 cm H2O, p = 0.03). The individualized mechanical ventilation group had lower concentrations in bronchoalveolar lavage of IL-6 (270 pg/mL vs 155 pg/mL, p = 0.02), TNF-α (292 pg/mL vs 139 pg/mL, p < 0.01) and IL-1ß (563 pg/mL vs 131 pg/mL, p = 0.05). They presented lower proportion of lymphocytes (96% vs 79%, p = 0.05) as well as lower lung injury score (6.0 points vs 2.0 points, p = 0.02).

CONCLUSION: In our model, individualization of DP to pulmonary elastance through Young's modulus decreases lung inflammation and structural lung injury without a significant impact on oxygenation.

来源:Crit Care,查看原文。版权归原作者所有。

参考来源

  1. Mingote Á, Marrero García R, Santos González M, et al. Individualizing mechanical ventilation: titration of driving pressure to pulmonary elastance through Young's modulus in an acute respiratory distress syndrome animal model. Crit Care. 2022. PMID: 36258235. doi:10.1186/s13054-022-04184-w

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。