重症患者无限制探视策略的有效性与安全性:一项Meta分析
该Meta分析纳入11项随机对照试验和准实验研究、共3741例ICU患者,比较无限制探视策略(UVP)与限制性探视策略(RVP)对谵妄、感染、死亡和ICU住院时间的影响。随机效应模型显示UVP与谵妄发生率降低相关(OR=0.4,95%CI 0.25-0.63,I²=71%,p=0.0005)。固定效应模型显示UVP不增加ICU获得性感染(包括呼吸机相关性肺炎、导管相关尿路感染、导管相关血流感染)或ICU死亡率。UVP可能缩短ICU住院时间(SMD=-0.97,95%CI -1.61至0.32,p=0.003)。作者认为需进一步大规模多中心研究确认。
要点
- UVP与谵妄发生率降低相关:OR=0.4(95%CI 0.25-0.63,I²=71%,p=0.0005),基于11项研究3741例患者。
- UVP不增加呼吸机相关性肺炎(OR=0.96,95%CI 0.71-1.30,I²=0%,p=0.49)、导管相关尿路感染(OR=0.97,95%CI 0.52-1.80,I²=0%,p=0.55)、导管相关血流感染(OR=1.15,95%CI 0.72-1.84,I²=0%,p=0.66)。
- UVP不增加ICU死亡率:OR=1.03(95%CI 0.83-1.28,I²=49%,p=0.12)。
- UVP可能缩短ICU住院时间:SMD=-0.97(95%CI -1.61至0.32,p=0.003)。
- 作者指出需进一步大规模多中心研究确认这些发现。
适用人群与场景
- ICU收治的重症患者,比较无限制探视策略与限制性探视策略。
研究设计与关键结果
- 研究设计:Meta分析,纳入随机对照试验和准实验研究,共11项研究、3741例患者,检索MEDLINE、Cochrane Library、Embase、Web of Science、CINAHL、CBMdisc、CNKI、Wanfang、VIP数据库自建库至2022年1月22日的记录。
- 主要结局:UVP与谵妄发生率降低相关(OR=0.4,95%CI 0.25-0.63,I²=71%,p=0.0005,随机效应模型)。
- 感染结局(固定效应模型):呼吸机相关性肺炎OR=0.96(95%CI 0.71-1.30,I²=0%,p=0.49);导管相关尿路感染OR=0.97(95%CI 0.52-1.80,I²=0%,p=0.55);导管相关血流感染OR=1.15(95%CI 0.72-1.84,I²=0%,p=0.66),UVP未增加这些感染的发生率。
- ICU死亡率:OR=1.03(95%CI 0.83-1.28,I²=49%,p=0.12),UVP未增加死亡率。
- ICU住院时间:UVP可能缩短ICU住院时间(SMD=-0.97,95%CI -1.61至0.32,p=0.003)。
证据类型、等级与局限
- 证据类型:Meta分析(纳入随机对照试验和准实验研究)。
- 局限性:作者指出需进一步大规模多中心研究确认这些发现。
对床旁实践的改变
- 作者认为,采用无限制探视策略可能显著降低ICU患者谵妄发生率,且不增加ICU获得性感染或死亡风险。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
AIM: To compare the safety and effects of unrestricted visiting policies (UVPs) and restricted visiting policies (RVPs) in intensive care units (ICUs) with respect to outcomes related to delirium, infection, and mortality.
METHODS: MEDLINE, Cochrane Library, Embase, Web of Science, CINAHL, CBMdisc, CNKI, Wanfang, and VIP database records generated from their inception to 22 January 2022 were searched. Randomized controlled trials and quasi-experimental studies were included. The main outcomes investigated were delirium, ICU-acquired infection, ICU mortality, and length of ICU stay. Two reviewers independently screened studies, extracted data, and assessed risks of bias. Random‑effects and fixed-effects meta‑analyses were conducted to obtain pooled estimates, due to heterogeneity. Meta-analyses were performed using RevMan 5.3 software. The results were analyzed using odds ratios (ORs), 95% confidence intervals (CIs), and standardized mean differences (SMDs).
RESULTS: Eleven studies including a total of 3741 patients that compared UVPs and RVPs in ICUs were included in the analyses. Random effects modeling indicated that UVPs were associated with a reduced incidence of delirium (OR = 0.4, 95% CI 0.25-0.63, I2 = 71%, p = 0.0005). Fixed-effects modeling indicated that UVPs did not increase the incidences of ICU-acquired infections, including ventilator-associated pneumonia (OR = 0.96, 95% CI 0.71-1.30, I2 = 0%, p = 0.49), catheter-associated urinary tract infection (OR 0.97, 95% CI 0.52-1.80, I2 = 0%, p = 0.55), and catheter-related blood stream infection (OR = 1.15, 95% CI 0.72-1.84, I2 = 0%, p = 0.66), or ICU mortality (OR = 1.03, 95% CI 0.83-1.28, I2 = 49%, p = 0.12). Forest plotting indicated that UVPs could reduce the lengths of ICU stays (SMD = - 0.97, 95% CI - 1.61 to 0.32, p = 0.003).
CONCLUSION: The current meta-analysis indicates that adopting a UVP may significantly reduce the incidence of delirium in ICU patients, without increasing the risks of ICU-acquired infection or mortality. Further large-scale, multicenter studies are needed to confirm these indications.
参考来源
- Wu Y, Wang G, Zhang Z, et al. Efficacy and safety of unrestricted visiting policy for critically ill patients: a meta-analysis. Crit Care. 2022. PMID: 36064613. doi:10.1186/s13054-022-04129-3
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。