COVID-19 ARDS患者仰卧位与俯卧位胸壁加载对呼吸力学和气体交换的影响
这项单中心前瞻性队列研究纳入40例机械通气的COVID-19相关ARDS危重患者,按呼吸系统顺应性分为较高组(≥40 ml/cmH2O)和较低组(<40 ml/cmH2O),依次进行仰卧位、仰卧位+10 kg持续胸壁压迫、俯卧位、俯卧位+10 kg持续胸壁压迫四个步骤,每步6小时。全队列中,仰卧位与仰卧位+加载之间氧合和呼吸系统顺应性均无变化,俯卧位期间两者均升高且不受胸壁加载影响,肺泡死腔在各步骤均无变化。在16例低顺应性患者中,PaO2/FiO2从仰卧位到仰卧位+加载、再到俯卧位和俯卧位+加载显著升高(107 ± 15.4 vs. 120 ± 18.5 vs. 146 ± 27.0 vs. 159 ± 30.4,p < 0.001),胸壁加载后仰卧位和俯卧位的肺泡死腔均下降,呼吸系统顺应性从仰卧位到仰卧位+加载及从俯卧位到俯卧位+加载均显著增加(23.9 ± 3.5 vs. 30.9 ± 5.7 和 31.1 ± 5.7 vs. 37.8 ± 8.7 ml/cmH2O,p < 0.001),基线顺应性越低改善越大。
要点
- 全队列40例中,仰卧位与仰卧位+10 kg胸壁加载之间氧合和呼吸系统顺应性无变化,俯卧位期间两者升高且不受胸壁加载影响。
- 16例低顺应性(<40 ml/cmH2O)患者中,PaO2/FiO2从仰卧位107 ± 15.4升至仰卧位+加载120 ± 18.5、俯卧位146 ± 27.0、俯卧位+加载159 ± 30.4(p < 0.001)。
- 低顺应性患者胸壁加载后仰卧位和俯卧位的肺泡死腔均下降。
- 低顺应性患者呼吸系统顺应性从仰卧位23.9 ± 3.5升至仰卧位+加载30.9 ± 5.7 ml/cmH2O,从俯卧位31.1 ± 5.7升至俯卧位+加载37.8 ± 8.7 ml/cmH2O(p < 0.001)。
- 改善幅度与基线顺应性相关:基线顺应性越低,改善越大。
适用人群与场景
- 单中心ICU连续纳入的机械通气COVID-19相关ARDS危重患者40例。
- 按呼吸系统顺应性分为较高组(≥40 ml/cmH2O)和较低组(<40 ml/cmH2O)。
诊断标准与关键阈值
- 呼吸系统顺应性分组界值:≥40 ml/cmH2O为较高组,<40 ml/cmH2O为较低组。
处置流程与药物剂量
- 研究步骤依次为:第一步仰卧位6小时;第二步仰卧位+10 kg持续胸壁压迫6小时;第三步俯卧位6小时;第四步俯卧位+10 kg持续胸壁压迫6小时。
- 在每个步骤结束时测量呼吸系统力学、气体交换和肺泡死腔。
研究设计与关键结果
- 单中心前瞻性队列研究,纳入40例机械通气COVID-19相关ARDS危重患者。
- 全队列中,仰卧位与仰卧位+胸壁加载之间氧合和呼吸系统顺应性无变化;俯卧位期间两者均升高,且俯卧位下胸壁加载不影响两者;肺泡死腔在所有步骤均无变化。
- 16例低顺应性患者中,PaO2/FiO2从仰卧位到仰卧位+加载、俯卧位、俯卧位+加载显著升高(107 ± 15.4 vs. 120 ± 18.5 vs. 146 ± 27.0 vs. 159 ± 30.4,p < 0.001)。
- 低顺应性患者胸壁加载后仰卧位和俯卧位的肺泡死腔均下降。
- 低顺应性患者呼吸系统顺应性从仰卧位到仰卧位+加载(23.9 ± 3.5 vs. 30.9 ± 5.7 ml/cmH2O)及从俯卧位到俯卧位+加载(31.1 ± 5.7 vs. 37.8 ± 8.7 ml/cmH2O)均显著增加(p < 0.001)。
- 改善幅度与基线顺应性相关:基线顺应性越低,改善越大。
证据类型、等级与局限
- 证据类型:单中心前瞻性队列研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 在未选择的COVID-19相关ARDS危重患者中,仰卧位胸壁加载对呼吸系统顺应性、气体交换或肺泡死腔无影响,不应常规据此加用胸壁加载。
- 仅低呼吸系统顺应性(<40 ml/cmH2O)患者可能从胸壁加载中获益,且基线顺应性越低改善越大,可考虑在此类患者中评估胸壁加载的效果。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Recent reports of patients with severe, late-stage COVID-19 ARDS with reduced respiratory system compliance described paradoxical decreases in plateau pressure and increases in respiratory system compliance in response to anterior chest wall loading. We aimed to assess the effect of chest wall loading during supine and prone position in ill patients with COVID-19-related ARDS and to investigate the effect of a low or normal baseline respiratory system compliance on the findings.
METHODS: This is a single-center, prospective, cohort study in the intensive care unit of a COVID-19 referral center. Consecutive mechanically ventilated, critically ill patients with COVID-19-related ARDS were enrolled and classified as higher (≥ 40 ml/cmH2O) or lower respiratory system compliance (< 40 ml/cmH2O). The study included four steps, each lasting 6 h: Step 1, supine position, Step 2, 10-kg continuous chest wall compression (supine + weight), Step 3, prone position, Step 4, 10-kg continuous chest wall compression (prone + weight). The mechanical properties of the respiratory system, gas exchange and alveolar dead space were measured at the end of each step.
RESULTS: Totally, 40 patients were enrolled. In the whole cohort, neither oxygenation nor respiratory system compliance changed between supine and supine + weight; both increased during prone positioning and were unaffected by chest wall loading in the prone position. Alveolar dead space was unchanged during all the steps. In 16 patients with reduced compliance, PaO2/FiO2 significantly increased from supine to supine + weight and further with prone and prone + weight (107 ± 15.4 vs. 120 ± 18.5 vs. 146 ± 27.0 vs. 159 ± 30.4, respectively; p < 0.001); alveolar dead space decreased from both supine and prone position after chest wall loading, and respiratory system compliance significantly increased from supine to supine + weight and from prone to prone + weight (23.9 ± 3.5 vs. 30.9 ± 5.7 and 31.1 ± 5.7 vs. 37.8 ± 8.7 ml/cmH2O, p < 0.001). The improvement was higher the lower the baseline compliance.
CONCLUSIONS: Unlike prone positioning, chest wall loading had no effects on respiratory system compliance, gas exchange or alveolar dead space in an unselected cohort of critically ill patients with C-ARDS. Only patients with a low respiratory system compliance experienced an improvement, with a higher response the lower the baseline compliance.
参考来源
- Umbrello M, Lassola S, Sanna A, et al. Chest wall loading during supine and prone position in patients with COVID-19 ARDS: effects on respiratory mechanics and gas exchange. Crit Care. 2022. PMID: 36100903. doi:10.1186/s13054-022-04141-7
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。