流量指数用于检测压力支持通气下低吸气努力的外验证
本研究基于100例急性脑损伤接受压力支持通气患者的流量、气道压和食管压波形数据,离线分析流量指数与食管压衍生吸气努力指标的相关性及诊断准确性。低吸气努力定义为WOB<0.3 J/L、每分钟PTPes<50 cmH2O•s/min或Pmus<5 cmH2O,三者均附加无效努力>10%。流量指数与WOB、Pmus、每次呼吸及每分钟PTPes呈中度相关(Pearson相关系数0.546–0.634,P<0.001)。以流量指数<2.1为界值,诊断三种定义低吸气努力的敏感度0.95–0.96、特异度0.57–0.71、阳性预测值0.70–0.84、阴性预测值0.90–0.93。流量指数可作为筛查低吸气努力的有效工具,高概率排除无该情况者。
要点
- 流量指数与WOB、Pmus、PTPes(每次呼吸及每分钟)呈中度相关,Pearson相关系数0.546–0.634(P<0.001)。
- 以流量指数<2.1为界值,诊断低吸气努力的敏感度0.95–0.96,阴性预测值0.90–0.93,高概率排除无低吸气努力者。
- 低吸气努力发生率:按WOB定义62%,按每分钟PTPes定义51%,按Pmus定义55%。
- 流量指数诊断低吸气努力的ROC曲线下面积分别为0.88(WOB)、0.81(每分钟PTPes)、0.88(Pmus)。
- 流量指数<2.1时特异度仅0.57–0.71,阳性预测值0.70–0.84,阳性结果需结合其他指标确认。
适用人群与场景
- 100例急性脑损伤接受压力支持通气的患者,波形数据来自先前发表的研究,离线分析。
诊断标准与关键阈值
- 低吸气努力定义为以下任一标准:WOB<0.3 J/L、每分钟PTPes<50 cmH2O•s/min或Pmus<5 cmH2O,所有标准均附加无效努力>10%。
- 流量指数界值<2.1用于诊断低吸气努力。
研究设计与关键结果
- 研究类型:对先前发表研究的波形数据进行离线分析的外部验证,样本量100例急性脑损伤压力支持通气患者。
- 流量指数与WOB、Pmus、每次呼吸及每分钟PTPes的Pearson相关系数为0.546–0.634(P<0.001)。
- 低吸气努力发生率:WOB定义62%,每分钟PTPes定义51%,Pmus定义55%。
- 流量指数诊断低吸气努力的ROC曲线下面积:WOB定义0.88,每分钟PTPes定义0.81,Pmus定义0.88。
- 流量指数<2.1诊断三种定义低吸气努力的敏感度0.95–0.96,特异度0.57–0.71,阳性预测值0.70–0.84,阴性预测值0.90–0.93。
证据类型、等级与局限
- 证据类型:对先前发表研究数据的离线分析外部验证。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为流量指数可作为筛查低吸气努力的有效工具,具有高概率排除无该情况的能力。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Bedside assessment of low levels of inspiratory effort, which are probably insufficient to prevent muscle atrophy, is challenging. The flow index, which is derived from the analysis of the inspiratory portion of the flow-time waveform, has been recently introduced as a non-invasive parameter to evaluate the inspiratory effort. The primary objective of the present study was to provide an external validation of the flow index to detect low inspiratory effort.
METHODS: Datasets containing flow, airway pressure, and esophageal pressure (Pes)-time waveforms were obtained from a previously published study in 100 acute brain-injured patients undergoing pressure support ventilation. Waveforms data were analyzed offline. A low inspiratory effort was defined by one of the following criteria, work of breathing (WOB) less than 0.3 J/L, Pes-time product (PTPes) per minute less than 50 cmH2O•s/min, or inspiratory muscle pressure (Pmus) less than 5 cmH2O, adding "or occurrence of ineffective effort more than 10%" for all criteria. The flow index was calculated according to previously reported method. The association of flow index with Pes-derived parameters of effort was investigated. The diagnostic accuracy of the flow index to detect low effort was analyzed.
RESULTS: Moderate correlations were found between flow index and WOB, Pmus, and PTPes per breath and per minute (Pearson's correlation coefficients ranged from 0.546 to 0.634, P < 0.001). The incidence of low inspiratory effort was 62%, 51%, and 55% using the definition of WOB, PTPes per minute, and Pmus, respectively. The area under the receiver operating characteristic curve for flow index to diagnose low effort was 0.88, 0.81, and 0.88, for the three respective definition. By using the cutoff value of flow index less than 2.1, the diagnostic performance for the three definitions showed sensitivity of 0.95-0.96, specificity of 0.57-0.71, positive predictive value of 0.70-0.84, and negative predictive value of 0.90-0.93.
CONCLUSIONS: The flow index is associated with Pes-based inspiratory effort measurements. Flow index can be used as a valid instrument to screen low inspiratory effort with a high probability to exclude cases without the condition.
参考来源
- Miao MY, Chen W, Zhou YM, et al. Validation of the flow index to detect low inspiratory effort during pressure support ventilation. Ann Intensive Care. 2022. PMID: 36161543. doi:10.1186/s13613-022-01063-z
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。