文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

PEEP-FiO2表与电阻抗断层成像指导的PEEP滴定在COVID-19相关ARDS机械通气患者中的比较

PEEP-FiO2 table versus EIT to titrate PEEP in mechanically ventilated patients with COVID-19-related ARDS.
PubMed 文献 · Crit Care · 2022-09-12
一句话结论在COVID-19相关中重度ARDS患者中,EIT指导的PEEP滴定使63%的患者PEEP发生≥2 cmH2O的调整,支持PEEP应个体化。

这项回顾性队列研究在ICU入院时对75例中重度COVID-19相关ARDS患者行EIT指导的递减PEEP试验,PEEP设定为相对肺泡过度膨胀与塌陷曲线交点以上的最低PEEP,并与高PEEP-FiO2表设定的基线PEEP比较。结果显示23例(31%)PEEP降低≥2 cmH2O,24例(32%)PEEP升高≥2 cmH2O,共63%患者PEEP发生相关变化。PEEP降低者呼吸力学改善、高PEEP时非依赖肺区过度膨胀更多,且BMI更低、症状至插管时间更长、肺栓塞发生率更高;PEEP升高者氧合改善。作者认为结果支持ARDS患者PEEP应个体化。

要点

  • 75例中重度COVID-19相关ARDS患者中,EIT指导的PEEP滴定使63%的患者PEEP改变≥2 cmH2O(降低31%、升高32%)。
  • PEEP降低≥2 cmH2O者呼吸力学改善,高PEEP时非依赖肺区过度膨胀更多,BMI更低、症状至插管时间更长、肺栓塞发生率更高。
  • PEEP升高≥2 cmH2O者氧合改善。
  • EIT指导的PEEP设定为相对肺泡过度膨胀与塌陷曲线交点以上的最低PEEP。
  • 作者认为结果支持ARDS患者PEEP应个体化。

适用人群与场景

  • ICU入院时的中重度COVID-19相关ARDS机械通气患者,共75例。

诊断标准与关键阈值

  • EIT指导的PEEP设定为相对肺泡过度膨胀与塌陷曲线交点以上的最低PEEP。
  • PEEP变化≥2 cmH2O定义为EIT指导的PEEP试验导致PEEP降低或升高。

处置流程与药物剂量

  • 对中重度COVID-19相关ARDS患者于ICU入院时行EIT指导的递减PEEP试验,PEEP设为相对肺泡过度膨胀与塌陷曲线交点以上的最低PEEP。
  • 将EIT设定的PEEP与按高PEEP-FiO2表设定的基线PEEP比较。

研究设计与关键结果

  • 回顾性队列研究,75例中重度COVID-19相关ARDS患者行EIT指导的PEEP试验。
  • 23例(31%)患者PEEP降低≥2 cmH2O,24例(32%)患者PEEP升高≥2 cmH2O,共63%患者PEEP发生相关变化。
  • PEEP降低者呼吸力学改善,高PEEP水平时非依赖肺区过度膨胀更多,BMI更低、症状至插管时间更长、肺栓塞发生率更高。
  • PEEP升高者氧合改善。

证据类型、等级与局限

  • 证据类型:回顾性队列研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,EIT指导的PEEP试验可使63%的中重度COVID-19相关ARDS患者PEEP发生≥2 cmH2O的改变,结果支持PEEP应个体化。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

RATIONALE: It is unknown how to titrate positive end-expiratory pressure (PEEP) in patients with COVID-19-related acute respiratory distress syndrome (ARDS). Guidelines recommend the one-size-fits-all PEEP-FiO2 table. In this retrospective cohort study, an electrical impedance tomography (EIT)-guided PEEP trial was used to titrate PEEP.

OBJECTIVES: To compare baseline PEEP according to the high PEEP-FiO2 table and personalized PEEP following an EIT-guided PEEP trial.

METHODS: We performed an EIT-guided decremental PEEP trial in patients with moderate-to-severe COVID-19-related ARDS upon intensive care unit admission. PEEP was set at the lowest PEEP above the intersection of curves representing relative alveolar overdistention and collapse. Baseline PEEP was compared with PEEP set according to EIT. We identified patients in whom the EIT-guided PEEP trial resulted in a decrease or increase in PEEP of ≥ 2 cmH2O.

MEASUREMENTS AND MAIN RESULTS: We performed a PEEP trial in 75 patients. In 23 (31%) patients, PEEP was decreased ≥ 2 cmH2O, and in 24 (32%) patients, PEEP was increased ≥ 2 cmH2O. Patients in whom PEEP was decreased had improved respiratory mechanics and more overdistention in the non-dependent lung region at higher PEEP levels. These patients also had a lower BMI, longer time between onset of symptoms and intubation, and higher incidence of pulmonary embolism. Oxygenation improved in patients in whom PEEP was increased.

CONCLUSIONS: An EIT-guided PEEP trial resulted in a relevant change in PEEP in 63% of patients. These results support the hypothesis that PEEP should be personalized in patients with ARDS.

来源:Crit Care,查看原文。版权归原作者所有。

参考来源

  1. Somhorst P, van der Zee P, Endeman H, et al. PEEP-FiO2 table versus EIT to titrate PEEP in mechanically ventilated patients with COVID-19-related ARDS. Crit Care. 2022. PMID: 36096837. doi:10.1186/s13054-022-04135-5

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。