建立模型测量运动车辆中失衡向量对高质量心肺复苏实施的影响
本研究旨在建立模型,测量患者转运过程中影响高质量心肺复苏(HQ-CPR)实施的加速度与急动度向量。三名参与者在运动车辆中完成共十八轮仅按压的HQ-CPR,车辆分别以最小化或增加线性与角向量的方式驾驶。测量指标包括按压分数(CF%)及深度>5 cm(D%)、频率100-120次/分(R%)、完全回弹(FR%)、手位置(HP%)正确的按压百分比,并计算复合HQ-CPR评分。单变量回归显示,线性加速度(B = -0.093%/m/s²,95% CI [-0.17 - -0.02],p = 0.02)、线性急动度(B = -0.134%/m/s³,95% CI [-0.26 - -0.01],p = 0.04)、角速度(B = -0.543%/radian/s,95% CI [-0.98 - -0.11],p = 0.02)和角加速度(B = 0.863%/radian/s²,95% CI [-1.69 - -0.03],p = 0.04)均负向影响HQ-CPR;FR%和R%随向量增大而负向关联,D%、HP%、CF%无差异。动态驾驶时Borg自觉用力评分更高(8 ± 1 vs 3.5 ± 1.53,p = 0.02)。作者认为该模型可可靠测量运动车辆中HQ-CPR时的线性与角向失衡向量,按压频率和完全回弹似乎是受影响最大的HQ-CPR变量。
要点
- 运动车辆中线性加速度每增加1 m/s²,复合HQ-CPR评分下降0.093%(95% CI [-0.17 - -0.02],p = 0.02)。
- 线性急动度每增加1 m/s³,复合HQ-CPR评分下降0.134%(95% CI [-0.26 - -0.01],p = 0.04)。
- 角速度每增加1 radian/s,复合HQ-CPR评分下降0.543%(95% CI [-0.98 - -0.11],p = 0.02);角加速度每增加1 radian/s²,评分下降0.863%(95% CI [-1.69 - -0.03],p = 0.04)。
- 向量增大与完全回弹百分比(FR%)和按压频率百分比(R%)负向关联;深度>5 cm百分比(D%)、手位置百分比(HP%)、按压分数(CF%)无差异。
- 动态驾驶时施救者Borg自觉用力评分高于平稳驾驶(8 ± 1 vs 3.5 ± 1.53,p = 0.02)。
适用人群与场景
- 三名参与者在运动车辆中实施仅按压HQ-CPR,共十八轮。
诊断标准与关键阈值
- 复合HQ-CPR评分计算公式:((D% + R% + FR% + HP%)/4) * CF%,其中D%为深度>5 cm的按压百分比,R%为频率100-120次/分的按压百分比,FR%为完全回弹百分比,HP%为手位置正确百分比,CF%为按压分数。
研究设计与关键结果
- 研究类型为模型建立与初步报告;三名参与者完成十八轮仅按压HQ-CPR;车辆以最小化或增加线性与角向量的方式驾驶;HQ-CPR数据、线性向量数据和陀螺仪数据在所有试验中均成功记录。
- 单变量回归:线性加速度B = -0.093%/m/s²(95% CI [-0.17 - -0.02],p = 0.02);线性急动度B = -0.134%/m/s³(95% CI [-0.26 - -0.01],p = 0.04);角速度B = -0.543%/radian/s(95% CI [-0.98 - -0.11],p = 0.02);角加速度B = 0.863%/radian/s²(95% CI [-1.69 - -0.03],p = 0.04),均显示HQ-CPR随向量增大而负向受影响。
- 向量增大与FR%和R%负向关联;D%、HP%、CF%无差异。
- 动态驾驶时Borg自觉用力评分较平稳驾驶更高(8 ± 1 vs 3.5 ± 1.53,p = 0.02)。
证据类型、等级与局限
- 证据类型:模型建立与初步报告(preliminary report),无原文给出的证据等级。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为该模型可可靠测量运动车辆中实施HQ-CPR时的线性与角向失衡向量;在这份初步报告中,按压频率和完全回弹似乎是运动车辆中最受影响的高质量心肺复苏变量。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
AIM: We sought to develop a model to measure the acceleration and jerk vectors affecting the performance of High-Quality Cardiopulmonary Resuscitation (HQ-CPR) during patient transport.
METHODS: Three participants completed a total of eighteen rounds of compression only HQ-CPR in a moving vehicle. The vehicle was driven in a manner that either minimized or increased linear and angular vectors. The HQ-CPR variables measured were compression fraction (CF%), and percentages of compressions with correct depth > 5 cm (D%), rate 100-120 (R%), full recoil (FR%), and hand position (HP%). A composite HQ-CPR score was calculated: ((D% + R% + FR% + HP%)/4) * CF%). Linear and gyroscopic data were measured in the X, Y, and Z axes. The perceived difficulty in performing HQ-CPR was measured with the Borg Rating of Perceived Exertion Scale.
RESULTS: HQ-CPR data, linear vector data, and gyroscopic data were successfully recorded in all trial evolutions. Univariate regression analysis demonstrated that HQ-CPR was negatively affected by increasing magnitudes of linear acceleration (B = -0.093%/m/s2, 95% CI [-0.17 - -0.02), p = 0.02], linear jerk (B = -0.134%/m/s3, 95% CI [-0.26 - -0.01], p = 0.04), angular velocity (B = -0.543%/radian/s, 95% CI [-0.98 - -0.11], p = 0.02), and angular acceleration (B = 0.863%/radian/s2, 95% CI [-1.69 - -0.03], p = 0.04). Increasing vectors were negatively associated with FR% and R%. No difference was seen in D%, HP%, or CF%. Borg Rating of Perceived Exertion was greater in dynamic driving evolutions (8 ± 1 vs 3.5 ± 1.53, p = 0.02).
CONCLUSION: This model reliably measured linear and angular off-balancing vectors experienced during the delivery of HQ-CPR in a moving vehicle. In this preliminary report, compression rate and full recoil appear to be HQ-CPR variables most affected in a moving vehicle.
参考来源
- Manoukian MAC, Rose JS, Brown SK, et al. Development of a model to measure the effect of off-balancing vectors on the delivery of high-quality CPR in a moving vehicle. Am J Emerg Med. 2022. PMID: 36137329. doi:10.1016/j.ajem.2022.08.059
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。