重症急性胰腺炎合并感染性胰腺坏死:预测导管引流失败与需坏死组织清除
本研究回顾性纳入2012至2016年法国三个大学医院ICU收治的72例重症急性胰腺炎疑似感染性胰腺坏死需导管引流的连续患者,评估既往列线图的外部效度并寻找其他引流失败预测因子。引流成功定义为无需后续坏死组织清除且存活,失败定义为死亡和/或因改善不充分需后续坏死组织清除。导管引流单独成功32例(44.4%),列线图预测失败的AUROC为0.71。多因素分析显示引流失败独立相关于较高体重指数(OR 1.12;95%CI 1.00-1.24;P=0.048)、异质性积液(OR 16.7;95%CI 1.83-152.46;P=0.01)和引流前24小时内发生呼吸衰竭(OR 18.34;95%CI 2.18-154.3;P=0.007)。作者认为将这些预测因子加入列线图可能有助于识别引流失败高危患者。
要点
- 72例重症急性胰腺炎疑似感染性胰腺坏死行导管引流患者中,仅32例(44.4%)单独引流成功,超过半数需坏死组织清除。
- 引流失败独立相关于较高体重指数(OR 1.12;95%CI 1.00-1.24;P=0.048)。
- 异质性积液与引流失败独立相关(OR 16.7;95%CI 1.83-152.46;P=0.01)。
- 导管引流前24小时内发生呼吸衰竭与引流失败独立相关(OR 18.34;95%CI 2.18-154.3;P=0.007)。
- 既往列线图预测导管引流失败的AUROC为0.71;作者认为加入异质性积液和呼吸衰竭可能有助于识别高危患者。
适用人群与场景
- 2012至2016年法国三个大学医院ICU连续收治的重症急性胰腺炎伴疑似感染性胰腺坏死、需导管引流的患者,共72例。
诊断标准与关键阈值
- 引流成功定义为无需后续坏死组织清除且存活;失败定义为死亡和/或因改善不充分需后续坏死组织清除。
研究设计与关键结果
- 回顾性研究,纳入三个大学医院ICU的72例重症急性胰腺炎疑似感染性胰腺坏死需导管引流患者,评估既往列线图外部效度并寻找其他失败预测因子。
- 导管引流单独成功32例(44.4%)。
- 列线图预测导管引流失败的AUROC为0.71。
- 多因素分析:较高体重指数与引流失败独立相关(OR 1.12;95%CI 1.00-1.24;P=0.048)。
- 多因素分析:异质性积液与引流失败独立相关(OR 16.7;95%CI 1.83-152.46;P=0.01)。
- 多因素分析:导管引流前24小时内发生呼吸衰竭与引流失败独立相关(OR 18.34;95%CI 2.18-154.3;P=0.007)。
证据类型、等级与局限
- 证据类型:回顾性研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,将异质性积液和呼吸衰竭加入列线图可能有助于识别导管引流失败高危患者。
指南或共识出处
- ClinicalTrials.gov注册号:NCT03234166。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Recent guidelines advocate a step-up approach for managing suspected infected pancreatic necrosis (IPN) during acute pancreatitis. Nearly half the patients require secondary necrosectomy after catheter drainage. Our primary objective was to assess the external validity of a previously reported nomogram for catheter drainage, based on four predictors of failure. Our secondary objectives were to identify other potential predictors of catheter-drainage failure. We retrospectively studied consecutive patients admitted to the intensive care units (ICUs) of three university hospitals in France between 2012 and 2016, for severe acute pancreatitis with suspected IPN requiring catheter drainage. We assessed drainage success and failure rates in 72 patients, with success defined as survival without subsequent necrosectomy and failure as death and/or subsequent necrosectomy required by inadequate improvement. We plotted the receiver operating characteristics (ROC) curve for the nomogram and computed the area under the curve (AUROC).
RESULTS: Catheter drainage alone was successful in 32 (44.4%) patients. The nomogram predicted catheter-drainage failure with an AUROC of 0.71. By multivariate analysis, catheter-drainage failure was independently associated with a higher body mass index [odds ratio (OR), 1.12; 95% confidence interval (95% CI), 1.00-1.24; P = 0.048], heterogeneous collection (OR, 16.7; 95% CI, 1.83-152.46; P = 0.01), and respiratory failure onset within 24 h before catheter drainage (OR, 18.34; 95% CI, 2.18-154.3; P = 0.007).
CONCLUSION: Over half the patients required necrosectomy after failed catheter drainage. Newly identified predictors of catheter-drainage failure were heterogeneous collection and respiratory failure. Adding these predictors to the nomogram might help to identify patients at high risk of catheter-drainage failure.
CLINICALTRIALS: gov number: NCT03234166.
参考来源
- Garret C, Douillard M, David A, et al. Infected pancreatic necrosis complicating severe acute pancreatitis in critically ill patients: predicting catheter drainage failure and need for necrosectomy. Ann Intensive Care. 2022. PMID: 35916981. doi:10.1186/s13613-022-01039-z
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。