二氧化碳动力学监测中重度COVID-19肺炎患者肺容积与血流对PEEP升高的反应:一项观察性研究

Capnodynamic monitoring of lung volume and blood flow in response to increased positive end-expiratory pressure in moderate to severe COVID-19 pneumonia: an observational study.
PubMed 文献 · Crit Care · 2022-07-31
一句话结论中重度COVID-19呼吸衰竭患者PEEP升高后氧合改善与呼气末肺容积和有效肺血流增加相关,二氧化碳动力学监测可在床旁评估PEEP的生理反应。

本研究对27例中重度COVID-19呼吸衰竭机械通气患者行二氧化碳动力学监测,将PEEP从基线(PEEPlow 11±2.7 cm H2O)升高50%至PEEPhigh(18±3.0 cm H2O)。15例应答者P/F比值升高55[24-86] mmHg(p<0.01),PEEPlow时呼气末肺容积较非应答者少461[82-839] ml(p=0.02);应答者PEEPhigh时呼气末肺容积与有效肺血流呈正相关(r=0.56[0.18-0.83],p=0.03),非应答者呈负相关(r=-0.65[-0.12至-0.89],p=0.02);应答者死腔降低-0.06[-0.02至-0.09]%(p<0.01);呼气末肺容积变化与复张肺容积(r=0.85[0.69-0.93],p<0.01)及复张-膨胀比(r=0.87[0.74-0.94],p<0.01)相关。研究显示二氧化碳动力学监测可在床旁评估PEEP的生理反应,以辅助个体化设置PEEP。

要点

  • 中重度COVID-19呼吸衰竭患者PEEP从11±2.7 cm H2O升至18±3.0 cm H2O,15例应答者P/F比值升高55[24-86] mmHg(p<0.01)。
  • PEEPlow时应答者呼气末肺容积较非应答者少461[82-839] ml(p=0.02),PEEPhigh时两组无统计学差异。
  • 应答者PEEPhigh时呼气末肺容积与有效肺血流正相关(r=0.56[0.18-0.83],p=0.03),非应答者呈负相关(r=-0.65[-0.12至-0.89],p=0.02)。
  • 应答者死腔降低-0.06[-0.02至-0.09]%(p<0.01);呼气末肺容积变化与复张肺容积(r=0.85[0.69-0.93],p<0.01)及复张-膨胀比(r=0.87[0.74-0.94],p<0.01)相关。
  • 该研究显示二氧化碳动力学监测可在床旁评估PEEP的生理反应,以辅助个体化设置PEEP。

适用人群与场景

  • COVID-19相关中重度呼吸衰竭、接受机械通气的患者,共27例。

诊断标准与关键阈值

  • 以PEEP升高后动脉氧分压与吸入氧分数比值(P/F比值)升高>20 mmHg定义为应答者,否则为非应答者。

处置流程与药物剂量

  • 在基线PEEPlow(11±2.7 cm H2O)基础上将PEEP升高50%至PEEPhigh(18±3.0 cm H2O),期间行二氧化碳动力学监测呼气末肺容积与有效肺血流。

研究设计与关键结果

  • 观察性研究,27例中重度COVID-19呼吸衰竭机械通气患者,PEEP从11±2.7 cm H2O升至18±3.0 cm H2O;15例应答者P/F比值升高55[24-86] mmHg,12例非应答者对应变化p<0.01。
  • PEEPlow时应答者呼气末肺容积较非应答者少461[82-839] ml(p=0.02),PEEPhigh时两组无统计学差异。
  • 应答者PEEPhigh时呼气末肺容积与有效肺血流正相关(r=0.56[0.18-0.83],p=0.03);非应答者肺容积增加与肺灌注降低呈负相关(r=-0.65[-0.12至-0.89],p=0.02)。
  • 应答者死腔降低-0.06[-0.02至-0.09]%(p<0.01)。
  • 呼气末肺容积变化与复张肺容积(r=0.85[0.69-0.93],p<0.01)及复张-膨胀比(r=0.87[0.74-0.94],p<0.01)相关。
  • 采用混合因子方差分析比较组均值差异,Pearson相关系数报告含95%CI。

证据类型、等级与局限

  • 证据类型:观察性研究(临床试验注册号NCT05082168,注册日期2021年10月18日)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,该研究显示二氧化碳动力学监测可在床旁评估PEEP的生理反应,以辅助个体化设置PEEP。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: The optimal level of positive end-expiratory pressure (PEEP) during mechanical ventilation for COVID-19 pneumonia remains debated and should ideally be guided by responses in both lung volume and perfusion. Capnodynamic monitoring allows both end-expiratory lung volume ([Formula: see text]) and effective pulmonary blood flow (EPBF) to be determined at the bedside with ongoing ventilation.

METHODS: Patients with COVID-19-related moderate to severe respiratory failure underwent capnodynamic monitoring of [Formula: see text] and EPBF during a step increase in PEEP by 50% above the baseline (PEEPlow to PEEPhigh). The primary outcome was a > 20 mm Hg increase in arterial oxygen tension to inspired fraction of oxygen (P/F) ratio to define responders versus non-responders. Secondary outcomes included changes in physiological dead space and correlations with independently determined recruited lung volume and the recruitment-to-inflation ratio at an instantaneous, single breath decrease in PEEP. Mixed factor ANOVA for group mean differences and correlations by Pearson's correlation coefficient are reported including their 95% confidence intervals.

RESULTS: Of 27 patients studied, 15 responders increased the P/F ratio by 55 [24-86] mm Hg compared to 12 non-responders (p < 0.01) as PEEPlow (11 ± 2.7 cm H2O) was increased to PEEPhigh (18 ± 3.0 cm H2O). The [Formula: see text] was 461 [82-839] ml less in responders at PEEPlow (p = 0.02) but not statistically different between groups at PEEPhigh. Responders increased both [Formula: see text] and EPBF at PEEPhigh (r = 0.56 [0.18-0.83], p = 0.03). In contrast, non-responders demonstrated a negative correlation (r = - 0.65 [- 0.12 to - 0.89], p = 0.02) with increased lung volume associated with decreased pulmonary perfusion. Decreased (- 0.06 [- 0.02 to - 0.09] %, p < 0.01) dead space was observed in responders. The change in [Formula: see text] correlated with both the recruited lung volume (r = 0.85 [0.69-0.93], p < 0.01) and the recruitment-to-inflation ratio (r = 0.87 [0.74-0.94], p < 0.01).

CONCLUSIONS: In mechanically ventilated patients with moderate to severe COVID-19 respiratory failure, improved oxygenation in response to increased PEEP was associated with increased end-expiratory lung volume and pulmonary perfusion. The change in end-expiratory lung volume was positively correlated with the lung volume recruited and the recruitment-to-inflation ratio. This study demonstrates the feasibility of capnodynamic monitoring to assess physiological responses to PEEP at the bedside to facilitate an individualised setting of PEEP.

TRIAL REGISTRATION: NCT05082168 (18th October 2021).

来源:Crit Care,查看原文。版权归原作者所有。