氧暴露强度随时间变化与机械通气危重患者死亡率相关
该研究基于MIMIC-IV数据库,纳入成人接受有创机械通气至少48小时的患者7784例,排除接受ECMO或入ICU超过24小时后才启动通气者,中位机械通气时长8.1天(IQR 3.8-28天),总体28天死亡率为26.3%。采用分段指数可加混合模型估计氧暴露与28天死亡率随时间变化的关联。校正基线与时间依赖混杂因素后,每日时间加权平均PaO2与FiO2均与28天死亡率升高相关,关联强度主要体现在病程早中期;整个病程中每日TWA-PaO2≥120 mmHg(HR 1.166,95%CI 1.059-1.284)或TWA-FiO2≥0.5(HR 1.496,95%CI 1.363-1.641)与死亡风险显著升高相关,并观察到有害暴露的累积效应。作者认为机械通气患者应仔细监测PaO2与FiO2,尤其是入ICU后的早中期。
要点
- 每日TWA-PaO2≥120 mmHg与28天死亡风险升高相关(HR 1.166,95%CI 1.059-1.284)。
- 每日TWA-FiO2≥0.5与28天死亡风险升高相关(HR 1.496,95%CI 1.363-1.641)。
- 氧暴露与死亡的关联强度主要体现在病程早中期,并存在累积效应。
- 研究纳入7784例成人有创机械通气≥48小时患者,总体28天死亡率26.3%。
- 作者认为应仔细监测机械通气患者的PaO2与FiO2,尤其是入ICU后的早中期。
适用人群与场景
- 成人(≥18岁)接受有创机械通气至少48小时的患者,数据来自MIMIC-IV数据库。
- 排除接受ECMO的患者,以及入ICU超过24小时后才启动机械通气的患者。
诊断标准与关键阈值
- 每日时间加权平均PaO2≥120 mmHg为有害氧暴露阈值。
- 每日时间加权平均FiO2≥0.5为有害氧暴露阈值。
研究设计与关键结果
- 研究类型为基于MIMIC-IV数据库的分析,最终纳入7784例患者。
- 中位有创机械通气时长8.1天(IQR 3.8-28天),总体28天死亡率26.3%。
- 采用分段指数可加混合模型估计随时间变化的关联强度。
- 校正基线与时间依赖混杂因素后,每日TWA-PaO2与TWA-FiO2均与28天死亡率升高相关,关联强度主要体现在病程早中期。
- 整个病程中每日TWA-PaO2≥120 mmHg与死亡风险升高相关(HR 1.166,95%CI 1.059-1.284)。
- 整个病程中每日TWA-FiO2≥0.5与死亡风险升高相关(HR 1.496,95%CI 1.363-1.641)。
- 观察到有害暴露(TWA-PaO2≥120 mmHg或TWA-FiO2≥0.5)的累积效应。
证据类型、等级与局限
- 证据类型:基于MIMIC-IV数据库的观察性分析。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为机械通气患者应仔细监测PaO2与FiO2,尤其是入ICU后的早中期。
- 本研究提示每日TWA-PaO2≥120 mmHg或TWA-FiO2≥0.5与28天死亡风险升高相关,且存在累积效应。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: There is no consensus exists regarding the association between oxygen exposure (arterial oxygen tension or fraction of inspired oxygen) and outcomes for patients with mechanical ventilation. Additionally, whether the association remains persistent over time is unknown. We aimed to explore the association between exposure to different intensities of oxygen exposure over time and 28-day mortality in patients with mechanical ventilation.
METHODS: We obtained data from the Medical Information Mart for Intensive Care IV (MIMIC-IV), which included adult (≥ 18 years) patients who received invasive mechanical ventilation for at least 48 h. We excluded patients who received extracorporeal membrane oxygenation (ECMO) or who initiated ventilation more than 24 h after ICU admission. The primary outcome was 28-day mortality. Piece-wise exponential additive mixed models were employed to estimate the strength of associations over time.
RESULTS: A total of 7784 patients were included in the final analysis. Patients had a median duration of invasive mechanical ventilation of 8.1 days (IQR: 3.8-28 days), and the overall 28-day mortality rate was 26.3%. After adjustment for baseline and time-dependent confounders, both daily time-weighted average (TWA) arterial oxygen tension (PaO2) and fraction of inspired oxygen (FiO2) were associated with increased 28-day mortality, and the strength of the association manifested predominantly in the early-middle course of illness. A significant increase in the hazard of death was found to be associated with daily exposure to TWA-PaO2 ≥ 120 mmHg (Hazard ratio 1.166, 95% CI 1.059-1.284) or TWA-FiO2 ≥ 0.5 (Hazard ratio 1.496, 95% CI 1.363-1.641) during the entire course. A cumulative effect of harmful exposure (TWA-PaO2 ≥ 120 mmHg or TWA-FiO2 ≥ 0.5) was also observed.
CONCLUSION: PaO2 and FiO2 should be carefully monitored in patients with mechanical ventilation, especially during the early-middle course after ICU admission. Cumulative exposure to higher intensities of oxygen exposure was associated with an increased risk of death.
参考来源
- Zhu Z, Zhou M, Wei Y, et al. Time-varying intensity of oxygen exposure is associated with mortality in critically ill patients with mechanical ventilation. Crit Care. 2022. PMID: 35932009. doi:10.1186/s13054-022-04114-w
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。